Cargando…
Beam related thermal losses on the cryogenic and vacuum systems of LEP
The LEP Collider was operated in 1997 with 60 superconducting four-cavity accelerating modules (about 2600 MV available) installed at the four interaction points. During operation for physics it was o bserved that the dissipated heat in the superconducting cavities is not only a function of the acce...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1998
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/353205 |
Sumario: | The LEP Collider was operated in 1997 with 60 superconducting four-cavity accelerating modules (about 2600 MV available) installed at the four interaction points. During operation for physics it was o bserved that the dissipated heat in the superconducting cavities is not only a function of the acceleration gradient but it also depends on beam characteristics: number of bunches, bunch length and cu rrent per bunch. These beam effects were not foreseen in the original heat budget of the LEP refrigerators. Three days of LEP Machine Development were dedicated in August 97 to clarifying the correlat ion of the losses with the beam characteristics. The beam dependent heat load of the cryogenic system for the superconducting cavities is described. The dependence on various beam parameters is presen ted and scaling laws are given. A possible explanation will be presented and the consequence for LEP operation will be discussed. |
---|