Cargando…

The WELL Detector

We introduce the WELL detector, a new type of position-sensitive gas proportional counter produced using advanced printed circuit board (PCB) technology. The WELL is based on a thin kapton foil, copp erclad on both sides. Charge amplifying micro-wells are etched into the first metal and kapton layer...

Descripción completa

Detalles Bibliográficos
Autores principales: Bellazzini, R, Bozzo, M, Brez, A, Gariano, G, Latronico, L, Lumb, N, Papanestis, A, Spandre, G, Massai, M M, Raffo, R, Spezziga, M A
Lenguaje:eng
Publicado: 1998
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-9002(98)01187-5
http://cds.cern.ch/record/355949
_version_ 1780892508931227648
author Bellazzini, R
Bozzo, M
Brez, A
Gariano, G
Latronico, L
Lumb, N
Papanestis, A
Spandre, G
Massai, M M
Raffo, R
Spezziga, M A
author_facet Bellazzini, R
Bozzo, M
Brez, A
Gariano, G
Latronico, L
Lumb, N
Papanestis, A
Spandre, G
Massai, M M
Raffo, R
Spezziga, M A
author_sort Bellazzini, R
collection CERN
description We introduce the WELL detector, a new type of position-sensitive gas proportional counter produced using advanced printed circuit board (PCB) technology. The WELL is based on a thin kapton foil, copp erclad on both sides. Charge amplifying micro-wells are etched into the first metal and kapton layers. These end on a micro-strip pattern which is defined on the second metal plane. The array of micr o-strips is used for read-out to obtain 1-D positional information. First results from our systematic assessment of this device are reported.
id cern-355949
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1998
record_format invenio
spelling cern-3559492019-09-30T06:29:59Zdoi:10.1016/S0168-9002(98)01187-5http://cds.cern.ch/record/355949engBellazzini, RBozzo, MBrez, AGariano, GLatronico, LLumb, NPapanestis, ASpandre, GMassai, M MRaffo, RSpezziga, M AThe WELL DetectorDetectors and Experimental TechniquesWe introduce the WELL detector, a new type of position-sensitive gas proportional counter produced using advanced printed circuit board (PCB) technology. The WELL is based on a thin kapton foil, copp erclad on both sides. Charge amplifying micro-wells are etched into the first metal and kapton layers. These end on a micro-strip pattern which is defined on the second metal plane. The array of micr o-strips is used for read-out to obtain 1-D positional information. First results from our systematic assessment of this device are reported.INFN-PI-AE-98-03oai:cds.cern.ch:3559491998-05-27
spellingShingle Detectors and Experimental Techniques
Bellazzini, R
Bozzo, M
Brez, A
Gariano, G
Latronico, L
Lumb, N
Papanestis, A
Spandre, G
Massai, M M
Raffo, R
Spezziga, M A
The WELL Detector
title The WELL Detector
title_full The WELL Detector
title_fullStr The WELL Detector
title_full_unstemmed The WELL Detector
title_short The WELL Detector
title_sort well detector
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/S0168-9002(98)01187-5
http://cds.cern.ch/record/355949
work_keys_str_mv AT bellazzinir thewelldetector
AT bozzom thewelldetector
AT breza thewelldetector
AT garianog thewelldetector
AT latronicol thewelldetector
AT lumbn thewelldetector
AT papanestisa thewelldetector
AT spandreg thewelldetector
AT massaimm thewelldetector
AT raffor thewelldetector
AT spezzigama thewelldetector
AT bellazzinir welldetector
AT bozzom welldetector
AT breza welldetector
AT garianog welldetector
AT latronicol welldetector
AT lumbn welldetector
AT papanestisa welldetector
AT spandreg welldetector
AT massaimm welldetector
AT raffor welldetector
AT spezzigama welldetector