Cargando…
Beam test results of inverted double Gap RPCs with high counting rate capability for the CMS experiment
Two medium size prototypes of Inverted Double Gap RPC were tested in H2 SPS beam at CERN in the intensity range up to 7 kHz/cm2. The detectors having identical construction, but made out of bakelite with the volume resistivity different by three orders of magnitude allowed the study of the impact of...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1997
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/358578 |
_version_ | 1780892583462961152 |
---|---|
author | Czyrkowski, Henryk Cwiok, M Dabrowski, R Dominik, Wojciech Górski, M Królikowski, J Majewski, P |
author_facet | Czyrkowski, Henryk Cwiok, M Dabrowski, R Dominik, Wojciech Górski, M Królikowski, J Majewski, P |
author_sort | Czyrkowski, Henryk |
collection | CERN |
description | Two medium size prototypes of Inverted Double Gap RPC were tested in H2 SPS beam at CERN in the intensity range up to 7 kHz/cm2. The detectors having identical construction, but made out of bakelite with the volume resistivity different by three orders of magnitude allowed the study of the impact of the electrode material conductivity on the RPC operation characteristics. The RPC made out of bakelite with 5*10^8 Ohm cm volume resistivity exhibits stable operation in the whole range of beam intensities with full efficiency and good timing properties. |
id | cern-358578 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1997 |
record_format | invenio |
spelling | cern-3585782019-09-30T06:29:59Zhttp://cds.cern.ch/record/358578engCzyrkowski, HenrykCwiok, MDabrowski, RDominik, WojciechGórski, MKrólikowski, JMajewski, PBeam test results of inverted double Gap RPCs with high counting rate capability for the CMS experimentDetectors and Experimental TechniquesTwo medium size prototypes of Inverted Double Gap RPC were tested in H2 SPS beam at CERN in the intensity range up to 7 kHz/cm2. The detectors having identical construction, but made out of bakelite with the volume resistivity different by three orders of magnitude allowed the study of the impact of the electrode material conductivity on the RPC operation characteristics. The RPC made out of bakelite with 5*10^8 Ohm cm volume resistivity exhibits stable operation in the whole range of beam intensities with full efficiency and good timing properties.CMS-CR-1998-001IFD-97-1oai:cds.cern.ch:3585781997-12-15 |
spellingShingle | Detectors and Experimental Techniques Czyrkowski, Henryk Cwiok, M Dabrowski, R Dominik, Wojciech Górski, M Królikowski, J Majewski, P Beam test results of inverted double Gap RPCs with high counting rate capability for the CMS experiment |
title | Beam test results of inverted double Gap RPCs with high counting rate capability for the CMS experiment |
title_full | Beam test results of inverted double Gap RPCs with high counting rate capability for the CMS experiment |
title_fullStr | Beam test results of inverted double Gap RPCs with high counting rate capability for the CMS experiment |
title_full_unstemmed | Beam test results of inverted double Gap RPCs with high counting rate capability for the CMS experiment |
title_short | Beam test results of inverted double Gap RPCs with high counting rate capability for the CMS experiment |
title_sort | beam test results of inverted double gap rpcs with high counting rate capability for the cms experiment |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/358578 |
work_keys_str_mv | AT czyrkowskihenryk beamtestresultsofinverteddoublegaprpcswithhighcountingratecapabilityforthecmsexperiment AT cwiokm beamtestresultsofinverteddoublegaprpcswithhighcountingratecapabilityforthecmsexperiment AT dabrowskir beamtestresultsofinverteddoublegaprpcswithhighcountingratecapabilityforthecmsexperiment AT dominikwojciech beamtestresultsofinverteddoublegaprpcswithhighcountingratecapabilityforthecmsexperiment AT gorskim beamtestresultsofinverteddoublegaprpcswithhighcountingratecapabilityforthecmsexperiment AT krolikowskij beamtestresultsofinverteddoublegaprpcswithhighcountingratecapabilityforthecmsexperiment AT majewskip beamtestresultsofinverteddoublegaprpcswithhighcountingratecapabilityforthecmsexperiment |