A High Resolution Spallation Driven Facility at the CERN-PS to Measure Neutron Cross Sections in the Interval from 1 eV to 250 MeV: a Relative Performance Assessment

In the proposed facility with 24 GeV PS beam on a Lead target, the number of produced neutrons exceeds 760 per proton. In comparison, with a LINAC (GELINA) one currently obtains only about 0.05 neutrons per electron of about 100 MeV. An additional factor of 2.5 for the CERN facility is due to the st...

Descripción completa

Detalles Bibliográficos
Autores principales: Rubbia, Carlo, Andriamonje, Samuel A, Bouvet-Bensimon, D, Buono, S, Cappi, R, Cennini, P, Gelès, C, Goulas, I, Kadi, Y, Pavlopoulos, P, Revol, Jean Pierre Charles, Tzima, A, Vlachoudis, V
Lenguaje:eng
Publicado: 1998
Materias:
Acceso en línea:http://cds.cern.ch/record/363828
_version_ 1780892800549650432
author Rubbia, Carlo
Andriamonje, Samuel A
Bouvet-Bensimon, D
Buono, S
Cappi, R
Cennini, P
Gelès, C
Goulas, I
Kadi, Y
Pavlopoulos, P
Revol, Jean Pierre Charles
Tzima, A
Vlachoudis, V
author_facet Rubbia, Carlo
Andriamonje, Samuel A
Bouvet-Bensimon, D
Buono, S
Cappi, R
Cennini, P
Gelès, C
Goulas, I
Kadi, Y
Pavlopoulos, P
Revol, Jean Pierre Charles
Tzima, A
Vlachoudis, V
author_sort Rubbia, Carlo
collection CERN
description In the proposed facility with 24 GeV PS beam on a Lead target, the number of produced neutrons exceeds 760 per proton. In comparison, with a LINAC (GELINA) one currently obtains only about 0.05 neutrons per electron of about 100 MeV. An additional factor of 2.5 for the CERN facility is due to the strong, forward peaking of the neutron flux, arising from the high proton energy and corresponding longitudinal boost. This huge factor in neutron yield per incident particle, namely 2.5 x 760/0.05 = 3.8 x 10^4, is only partially off-set by the higher, time averaged current of the LINAC e.g. 100 mA vs . 2 mA of the CERN-PS. Therefore the useful, initial neutron rate at the CERN facility is about three orders of magnitude larger than in the most performing electron LINAC’s, GELINA in Belgium and ORELLA in the US. The time duration of the PS pulse is presently Deltat|_r.m.s.=13.5 ns and we believe it could be reduced to Deltat|_r.m.s.= 6.75 ns. The electron LINAC has much shorter pulses Deltat| _r.m.s.= 1 ns, to which however the resolution of the counters has to be added. But for neutron energy 1 MeV, is not affecting the actual TOF energy resolution, dominated by the fluctuations of moderation. Since these time fluctuations are largely independent of the chosen mechanism to produce the initial neutrons, the initial flux difference between the two methods, e.g. electrons vs. protons, reflects directly in the counting rate for a given TOF resolution at the measuring station. Furthermore the CERN PS (< 1/2.4 sec^-1) has a much smaller repetition rate than the LINAC (1 /800 sec-1) and it presents no problems of time overlaps at the measuring station due to successive bunches. The accidental background due to radio-active targets is also much better suppressed. Finally the gamma-prompt flash is considerably smaller for a proton machine than in the case of an electron LINAC and no gamma-filters are required.
id cern-363828
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1998
record_format invenio
spelling cern-3638282023-05-31T14:19:16Zhttp://cds.cern.ch/record/363828engRubbia, CarloAndriamonje, Samuel ABouvet-Bensimon, DBuono, SCappi, RCennini, PGelès, CGoulas, IKadi, YPavlopoulos, PRevol, Jean Pierre CharlesTzima, AVlachoudis, VA High Resolution Spallation Driven Facility at the CERN-PS to Measure Neutron Cross Sections in the Interval from 1 eV to 250 MeV: a Relative Performance AssessmentAccelerators and Storage RingsIn the proposed facility with 24 GeV PS beam on a Lead target, the number of produced neutrons exceeds 760 per proton. In comparison, with a LINAC (GELINA) one currently obtains only about 0.05 neutrons per electron of about 100 MeV. An additional factor of 2.5 for the CERN facility is due to the strong, forward peaking of the neutron flux, arising from the high proton energy and corresponding longitudinal boost. This huge factor in neutron yield per incident particle, namely 2.5 x 760/0.05 = 3.8 x 10^4, is only partially off-set by the higher, time averaged current of the LINAC e.g. 100 mA vs . 2 mA of the CERN-PS. Therefore the useful, initial neutron rate at the CERN facility is about three orders of magnitude larger than in the most performing electron LINAC’s, GELINA in Belgium and ORELLA in the US. The time duration of the PS pulse is presently Deltat|_r.m.s.=13.5 ns and we believe it could be reduced to Deltat|_r.m.s.= 6.75 ns. The electron LINAC has much shorter pulses Deltat| _r.m.s.= 1 ns, to which however the resolution of the counters has to be added. But for neutron energy 1 MeV, is not affecting the actual TOF energy resolution, dominated by the fluctuations of moderation. Since these time fluctuations are largely independent of the chosen mechanism to produce the initial neutrons, the initial flux difference between the two methods, e.g. electrons vs. protons, reflects directly in the counting rate for a given TOF resolution at the measuring station. Furthermore the CERN PS (< 1/2.4 sec^-1) has a much smaller repetition rate than the LINAC (1 /800 sec-1) and it presents no problems of time overlaps at the measuring station due to successive bunches. The accidental background due to radio-active targets is also much better suppressed. Finally the gamma-prompt flash is considerably smaller for a proton machine than in the case of an electron LINAC and no gamma-filters are required.CERN-LHC-98-002-EET-Add.1oai:cds.cern.ch:3638281998-06-15
spellingShingle Accelerators and Storage Rings
Rubbia, Carlo
Andriamonje, Samuel A
Bouvet-Bensimon, D
Buono, S
Cappi, R
Cennini, P
Gelès, C
Goulas, I
Kadi, Y
Pavlopoulos, P
Revol, Jean Pierre Charles
Tzima, A
Vlachoudis, V
A High Resolution Spallation Driven Facility at the CERN-PS to Measure Neutron Cross Sections in the Interval from 1 eV to 250 MeV: a Relative Performance Assessment
title A High Resolution Spallation Driven Facility at the CERN-PS to Measure Neutron Cross Sections in the Interval from 1 eV to 250 MeV: a Relative Performance Assessment
title_full A High Resolution Spallation Driven Facility at the CERN-PS to Measure Neutron Cross Sections in the Interval from 1 eV to 250 MeV: a Relative Performance Assessment
title_fullStr A High Resolution Spallation Driven Facility at the CERN-PS to Measure Neutron Cross Sections in the Interval from 1 eV to 250 MeV: a Relative Performance Assessment
title_full_unstemmed A High Resolution Spallation Driven Facility at the CERN-PS to Measure Neutron Cross Sections in the Interval from 1 eV to 250 MeV: a Relative Performance Assessment
title_short A High Resolution Spallation Driven Facility at the CERN-PS to Measure Neutron Cross Sections in the Interval from 1 eV to 250 MeV: a Relative Performance Assessment
title_sort high resolution spallation driven facility at the cern-ps to measure neutron cross sections in the interval from 1 ev to 250 mev: a relative performance assessment
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/363828
work_keys_str_mv AT rubbiacarlo ahighresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT andriamonjesamuela ahighresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT bouvetbensimond ahighresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT buonos ahighresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT cappir ahighresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT cenninip ahighresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT gelesc ahighresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT goulasi ahighresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT kadiy ahighresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT pavlopoulosp ahighresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT revoljeanpierrecharles ahighresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT tzimaa ahighresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT vlachoudisv ahighresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT rubbiacarlo highresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT andriamonjesamuela highresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT bouvetbensimond highresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT buonos highresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT cappir highresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT cenninip highresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT gelesc highresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT goulasi highresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT kadiy highresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT pavlopoulosp highresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT revoljeanpierrecharles highresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT tzimaa highresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment
AT vlachoudisv highresolutionspallationdrivenfacilityatthecernpstomeasureneutroncrosssectionsintheintervalfrom1evto250mevarelativeperformanceassessment