Cargando…

Thermal Characterization of the HeII LHC Heat Exchanger Tube

The LHC magnet cooling scheme is based on a HeII bayonet heat exchanger, which acts as a quasi isothermal heat sink. In order to assess the thermal performance of the oxygen free, annealed/cold worked copper tube, measurements of the total thermal conductance of the tube were performed in a laborato...

Descripción completa

Detalles Bibliográficos
Autores principales: Camacho, D, Chevassus, S, Policella, C, Rieubland, Jean Michel, Vandoni, Giovanna, Van Weelderen, R
Lenguaje:eng
Publicado: 1998
Materias:
Acceso en línea:http://cds.cern.ch/record/365293
Descripción
Sumario:The LHC magnet cooling scheme is based on a HeII bayonet heat exchanger, which acts as a quasi isothermal heat sink. In order to assess the thermal performance of the oxygen free, annealed/cold worked copper tube, measurements of the total thermal conductance of the tube were performed in a laboratory set-up. This paper describes the experimental technique, which permits to separate the contributio n of the Kapitza interface resistance from the total transverse conductance. The influence of the surface treatment on the Kapitza resistance is also discussed.