Thermal Characterization of the HeII LHC Heat Exchanger Tube
The LHC magnet cooling scheme is based on a HeII bayonet heat exchanger, which acts as a quasi isothermal heat sink. In order to assess the thermal performance of the oxygen free, annealed/cold worked copper tube, measurements of the total thermal conductance of the tube were performed in a laborato...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1998
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/365293 |
Sumario: | The LHC magnet cooling scheme is based on a HeII bayonet heat exchanger, which acts as a quasi isothermal heat sink. In order to assess the thermal performance of the oxygen free, annealed/cold worked copper tube, measurements of the total thermal conductance of the tube were performed in a laboratory set-up. This paper describes the experimental technique, which permits to separate the contributio n of the Kapitza interface resistance from the total transverse conductance. The influence of the surface treatment on the Kapitza resistance is also discussed. |
---|