Cargando…

Program for a novel ion gantry

In conjunction with the CERN-based development of a specially designed cancer therapy synchrotron (Proton-Ion Medical Machine Study - PIMMS), the need for the development of a facility equipped with an ion gantry emerged. Such a medical machine shall be capable of delivering a carbon ion beam virtua...

Descripción completa

Detalles Bibliográficos
Autor principal: Reimoser, S
Lenguaje:eng
Publicado: 1998
Materias:
Acceso en línea:http://cds.cern.ch/record/368732
_version_ 1780893024770850816
author Reimoser, S
author_facet Reimoser, S
author_sort Reimoser, S
collection CERN
description In conjunction with the CERN-based development of a specially designed cancer therapy synchrotron (Proton-Ion Medical Machine Study - PIMMS), the need for the development of a facility equipped with an ion gantry emerged. Such a medical machine shall be capable of delivering a carbon ion beam virtually from every position and direction best suited for the treatment of the patient. Therefore the gantry allows to conform the delivered dose very closely to the tumour volume, minimise the dose deposited in healthy tissue and spare any critical organs. The technical challenges for the design are the high beam rigidity of the ion beam, requiring large and very heavy bending magnets, as well as the specified high precision of the whole system.
id cern-368732
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1998
record_format invenio
spelling cern-3687322019-09-30T06:29:59Zhttp://cds.cern.ch/record/368732engReimoser, SProgram for a novel ion gantryEngineeringIn conjunction with the CERN-based development of a specially designed cancer therapy synchrotron (Proton-Ion Medical Machine Study - PIMMS), the need for the development of a facility equipped with an ion gantry emerged. Such a medical machine shall be capable of delivering a carbon ion beam virtually from every position and direction best suited for the treatment of the patient. Therefore the gantry allows to conform the delivered dose very closely to the tumour volume, minimise the dose deposited in healthy tissue and spare any critical organs. The technical challenges for the design are the high beam rigidity of the ion beam, requiring large and very heavy bending magnets, as well as the specified high precision of the whole system.CERN-ST-98-036oai:cds.cern.ch:3687321998-10-22
spellingShingle Engineering
Reimoser, S
Program for a novel ion gantry
title Program for a novel ion gantry
title_full Program for a novel ion gantry
title_fullStr Program for a novel ion gantry
title_full_unstemmed Program for a novel ion gantry
title_short Program for a novel ion gantry
title_sort program for a novel ion gantry
topic Engineering
url http://cds.cern.ch/record/368732
work_keys_str_mv AT reimosers programforanoveliongantry