A new wide band time normaliser circuit for bunch position measurements with high bandwidth and wide dynamic range

Trajectory and closed orbit measurements are vital for commissioning and operation of accelerators. With the push for high luminosities at modern colliders, the azimuthal bunch distribution becomes very complex, so that various phenomena (beam-beam forces, wake fields) strongly affect the orbits of...

Descripción completa

Detalles Bibliográficos
Autores principales: Cocq, D, Schmickler, Hermann, Vismara, Giuseppe
Lenguaje:eng
Publicado: 1998
Materias:
Acceso en línea:http://cds.cern.ch/record/370464
_version_ 1780893094673121280
author Cocq, D
Schmickler, Hermann
Vismara, Giuseppe
author_facet Cocq, D
Schmickler, Hermann
Vismara, Giuseppe
author_sort Cocq, D
collection CERN
description Trajectory and closed orbit measurements are vital for commissioning and operation of accelerators. With the push for high luminosities at modern colliders, the azimuthal bunch distribution becomes very complex, so that various phenomena (beam-beam forces, wake fields) strongly affect the orbits of individual bunches. Hence a system with high bandwidth capable of measuring the transverse position of any bunch is desirable. With the current techniques a bandwidth above 100 MHz can only be achieved by individual integration and digitisation of the pick-up signals. The drawback of such an approach is the limited dynamic range of typically 30 dB. In the context of the development of an orbit system for the LHC at CERN a high bandwidth could be achieved by extending the principle of phase normalisation to a wide band time normalisation of the position monitor signals. The circuit described in this paper (Wide band time normalizer) combines the signals of two pick-up electrodes with different delays and converts the beam position information into a pulse width modulation of the digital output signal. This way a bandwidth of more than 40 MHz and a dynamic range of about 50 dB could be achieved. The paper introduces the requirements for the LHC orbit system, compares various technical solutions and finally explains the working principle of the wide band time normalizer including some laboratory tests results.
id cern-370464
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1998
record_format invenio
spelling cern-3704642023-05-05T13:07:30Zhttp://cds.cern.ch/record/370464engCocq, DSchmickler, HermannVismara, GiuseppeA new wide band time normaliser circuit for bunch position measurements with high bandwidth and wide dynamic rangeAccelerators and Storage RingsTrajectory and closed orbit measurements are vital for commissioning and operation of accelerators. With the push for high luminosities at modern colliders, the azimuthal bunch distribution becomes very complex, so that various phenomena (beam-beam forces, wake fields) strongly affect the orbits of individual bunches. Hence a system with high bandwidth capable of measuring the transverse position of any bunch is desirable. With the current techniques a bandwidth above 100 MHz can only be achieved by individual integration and digitisation of the pick-up signals. The drawback of such an approach is the limited dynamic range of typically 30 dB. In the context of the development of an orbit system for the LHC at CERN a high bandwidth could be achieved by extending the principle of phase normalisation to a wide band time normalisation of the position monitor signals. The circuit described in this paper (Wide band time normalizer) combines the signals of two pick-up electrodes with different delays and converts the beam position information into a pulse width modulation of the digital output signal. This way a bandwidth of more than 40 MHz and a dynamic range of about 50 dB could be achieved. The paper introduces the requirements for the LHC orbit system, compares various technical solutions and finally explains the working principle of the wide band time normalizer including some laboratory tests results.CERN-SL-98-064-BIoai:cds.cern.ch:3704641998-11-04
spellingShingle Accelerators and Storage Rings
Cocq, D
Schmickler, Hermann
Vismara, Giuseppe
A new wide band time normaliser circuit for bunch position measurements with high bandwidth and wide dynamic range
title A new wide band time normaliser circuit for bunch position measurements with high bandwidth and wide dynamic range
title_full A new wide band time normaliser circuit for bunch position measurements with high bandwidth and wide dynamic range
title_fullStr A new wide band time normaliser circuit for bunch position measurements with high bandwidth and wide dynamic range
title_full_unstemmed A new wide band time normaliser circuit for bunch position measurements with high bandwidth and wide dynamic range
title_short A new wide band time normaliser circuit for bunch position measurements with high bandwidth and wide dynamic range
title_sort new wide band time normaliser circuit for bunch position measurements with high bandwidth and wide dynamic range
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/370464
work_keys_str_mv AT cocqd anewwidebandtimenormalisercircuitforbunchpositionmeasurementswithhighbandwidthandwidedynamicrange
AT schmicklerhermann anewwidebandtimenormalisercircuitforbunchpositionmeasurementswithhighbandwidthandwidedynamicrange
AT vismaragiuseppe anewwidebandtimenormalisercircuitforbunchpositionmeasurementswithhighbandwidthandwidedynamicrange
AT cocqd newwidebandtimenormalisercircuitforbunchpositionmeasurementswithhighbandwidthandwidedynamicrange
AT schmicklerhermann newwidebandtimenormalisercircuitforbunchpositionmeasurementswithhighbandwidthandwidedynamicrange
AT vismaragiuseppe newwidebandtimenormalisercircuitforbunchpositionmeasurementswithhighbandwidthandwidedynamicrange