High-current performance evaluation of DCCTs

The evaluation of high performance DCCT's to the ppm level has never been an easy task. With the LHC demanding currents up to 13 kA, a whole series of problems has arisen in the accurate measurement of these devices. In order to tackle these problems, new facilities have been designed for labor...

Descripción completa

Detalles Bibliográficos
Autores principales: Bordry, Frederick, Fernqvist, G, Halvarsson, Bjorn, Perréard, J C, Pett, John G
Lenguaje:eng
Publicado: 1998
Materias:
Acceso en línea:http://cds.cern.ch/record/375588
_version_ 1780893242906116096
author Bordry, Frederick
Fernqvist, G
Halvarsson, Bjorn
Perréard, J C
Pett, John G
author_facet Bordry, Frederick
Fernqvist, G
Halvarsson, Bjorn
Perréard, J C
Pett, John G
author_sort Bordry, Frederick
collection CERN
description The evaluation of high performance DCCT's to the ppm level has never been an easy task. With the LHC demanding currents up to 13 kA, a whole series of problems has arisen in the accurate measurement of these devices. In order to tackle these problems, new facilities have been designed for laboratory measurements under full power operating conditions. These include a high performance low voltage 20 kA power converter, quasi-coaxial bus-bar structures, Kusters Bridge range extenders and a novel bipolar 0 - 10 A current calibrator with resolution and linearity better than ± 0.5 ppm. This paper will present an overview of the complete facility and give more detail on the new current calibrator. Initial results will be presented, along with application areas which advance the state of the art in this field of measurements.
id cern-375588
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1998
record_format invenio
spelling cern-3755882023-05-05T13:07:31Zhttp://cds.cern.ch/record/375588engBordry, FrederickFernqvist, GHalvarsson, BjornPerréard, J CPett, John GHigh-current performance evaluation of DCCTsAccelerators and Storage RingsThe evaluation of high performance DCCT's to the ppm level has never been an easy task. With the LHC demanding currents up to 13 kA, a whole series of problems has arisen in the accurate measurement of these devices. In order to tackle these problems, new facilities have been designed for laboratory measurements under full power operating conditions. These include a high performance low voltage 20 kA power converter, quasi-coaxial bus-bar structures, Kusters Bridge range extenders and a novel bipolar 0 - 10 A current calibrator with resolution and linearity better than ± 0.5 ppm. This paper will present an overview of the complete facility and give more detail on the new current calibrator. Initial results will be presented, along with application areas which advance the state of the art in this field of measurements.CERN-SL-98-069-POoai:cds.cern.ch:3755881998-12-01
spellingShingle Accelerators and Storage Rings
Bordry, Frederick
Fernqvist, G
Halvarsson, Bjorn
Perréard, J C
Pett, John G
High-current performance evaluation of DCCTs
title High-current performance evaluation of DCCTs
title_full High-current performance evaluation of DCCTs
title_fullStr High-current performance evaluation of DCCTs
title_full_unstemmed High-current performance evaluation of DCCTs
title_short High-current performance evaluation of DCCTs
title_sort high-current performance evaluation of dccts
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/375588
work_keys_str_mv AT bordryfrederick highcurrentperformanceevaluationofdccts
AT fernqvistg highcurrentperformanceevaluationofdccts
AT halvarssonbjorn highcurrentperformanceevaluationofdccts
AT perreardjc highcurrentperformanceevaluationofdccts
AT pettjohng highcurrentperformanceevaluationofdccts