Final tests of the CsI-based ring imaging detector for the ALICE experiment

We report on the final tests performed on a CsI-based RICH detector equipped with 2 C$_6$F$_{14}$ radiator trays and 4 photocathodes, each of 64$\times$38 cm$^2$ area. The overall performance of the detector is described, using different gas mixtures, in view of optimizing the photoelectron yield an...

Descripción completa

Detalles Bibliográficos
Autores principales: Piuz, François, Braem, André, Davenport, Martyn, Di Bari, D, Di Mauro, A, Elia, D, Goret, B, Martinengo, P, Nappi, E, Paic, G, Santiard, Jean-Claude, Stucchi, S, Tomasicchio, G, Williams, T D
Lenguaje:eng
Publicado: 1999
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-9002(99)00349-6
http://cds.cern.ch/record/381683
Descripción
Sumario:We report on the final tests performed on a CsI-based RICH detector equipped with 2 C$_6$F$_{14}$ radiator trays and 4 photocathodes, each of 64$\times$38 cm$^2$ area. The overall performance of the detector is described, using different gas mixtures, in view of optimizing the photoelectron yield and the pad occupancy. Test results under magnetic field up to 0.9 T, photocathode homogeneity and stability are presented.