Cargando…

Effect on a Hadron Shower Leakage on the Energy Response and Resolution of Hadron Tile Calorimeter

The hadronic shower longitudinal and lateral leakages and its effect on the pion response and energy resolution of iron-scintillator barrel hadron prototype calorimeter with longitudinal tile configuration with a thickness of 9.4 nuclear interaction lengths have been investigated. The results are ba...

Descripción completa

Detalles Bibliográficos
Autores principales: Kulchitsky, Y.A., Rumyantsev, V.S., Budagov, J.A., Vinogradov, V.B., Karapetian, G., Nessi, M., Bogush, A.A.
Lenguaje:eng
Publicado: 1999
Materias:
Acceso en línea:http://cds.cern.ch/record/382530
_version_ 1780893470459691008
author Kulchitsky, Y.A.
Rumyantsev, V.S.
Budagov, J.A.
Vinogradov, V.B.
Karapetian, G.
Nessi, M.
Bogush, A.A.
author_facet Kulchitsky, Y.A.
Rumyantsev, V.S.
Budagov, J.A.
Vinogradov, V.B.
Karapetian, G.
Nessi, M.
Bogush, A.A.
author_sort Kulchitsky, Y.A.
collection CERN
description The hadronic shower longitudinal and lateral leakages and its effect on the pion response and energy resolution of iron-scintillator barrel hadron prototype calorimeter with longitudinal tile configuration with a thickness of 9.4 nuclear interaction lengths have been investigated. The results are based on 100 GeV pion beam data at incidence angle $\Theta = 10^o$ at impact point Z in the range from - 36 to 20 cm which were obtained during test beam period in May 1995 with setup equipped scintillator detector planes placed behind and back of the calorimeter. The fraction of the energy of 100 GeV pions at $\Theta = 10^o$ leaking out at the back of this calorimeter amounts to 1.8 % and agrees with the one for a conventional iron-scintillator calorimeter. Unexpected behaviour of the energy resolution as a function of leakage is observed: 6 % lateral leakage lead to 18 % improving of energy resolution in compare with the showers without leakage. The measured values of longitudinal punchthrough probability $(18 \pm 1) %$ and $(20 \pm 1) %$ for two different hit definitions of leaking events agree with the earlier measurement for our calorimeter and with the one for a conventional iron-scintillator calorimeter with the same nuclear interaction length thickness respectively. Due to more soft cut for hit definition in the leakage detectors the measured value of longitudinal punchthrough probability more corresponds to the calculated iron equivalent length $L_{Fe} = 158 cm$.
id cern-382530
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1999
record_format invenio
spelling cern-3825302019-09-30T06:29:59Zhttp://cds.cern.ch/record/382530engKulchitsky, Y.A.Rumyantsev, V.S.Budagov, J.A.Vinogradov, V.B.Karapetian, G.Nessi, M.Bogush, A.A.Effect on a Hadron Shower Leakage on the Energy Response and Resolution of Hadron Tile CalorimeterDetectors and Experimental TechniquesThe hadronic shower longitudinal and lateral leakages and its effect on the pion response and energy resolution of iron-scintillator barrel hadron prototype calorimeter with longitudinal tile configuration with a thickness of 9.4 nuclear interaction lengths have been investigated. The results are based on 100 GeV pion beam data at incidence angle $\Theta = 10^o$ at impact point Z in the range from - 36 to 20 cm which were obtained during test beam period in May 1995 with setup equipped scintillator detector planes placed behind and back of the calorimeter. The fraction of the energy of 100 GeV pions at $\Theta = 10^o$ leaking out at the back of this calorimeter amounts to 1.8 % and agrees with the one for a conventional iron-scintillator calorimeter. Unexpected behaviour of the energy resolution as a function of leakage is observed: 6 % lateral leakage lead to 18 % improving of energy resolution in compare with the showers without leakage. The measured values of longitudinal punchthrough probability $(18 \pm 1) %$ and $(20 \pm 1) %$ for two different hit definitions of leaking events agree with the earlier measurement for our calorimeter and with the one for a conventional iron-scintillator calorimeter with the same nuclear interaction length thickness respectively. Due to more soft cut for hit definition in the leakage detectors the measured value of longitudinal punchthrough probability more corresponds to the calculated iron equivalent length $L_{Fe} = 158 cm$.hep-ex/9903051JINR-E1-96-180AJINR-E1-96-180oai:cds.cern.ch:3825301999
spellingShingle Detectors and Experimental Techniques
Kulchitsky, Y.A.
Rumyantsev, V.S.
Budagov, J.A.
Vinogradov, V.B.
Karapetian, G.
Nessi, M.
Bogush, A.A.
Effect on a Hadron Shower Leakage on the Energy Response and Resolution of Hadron Tile Calorimeter
title Effect on a Hadron Shower Leakage on the Energy Response and Resolution of Hadron Tile Calorimeter
title_full Effect on a Hadron Shower Leakage on the Energy Response and Resolution of Hadron Tile Calorimeter
title_fullStr Effect on a Hadron Shower Leakage on the Energy Response and Resolution of Hadron Tile Calorimeter
title_full_unstemmed Effect on a Hadron Shower Leakage on the Energy Response and Resolution of Hadron Tile Calorimeter
title_short Effect on a Hadron Shower Leakage on the Energy Response and Resolution of Hadron Tile Calorimeter
title_sort effect on a hadron shower leakage on the energy response and resolution of hadron tile calorimeter
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/382530
work_keys_str_mv AT kulchitskyya effectonahadronshowerleakageontheenergyresponseandresolutionofhadrontilecalorimeter
AT rumyantsevvs effectonahadronshowerleakageontheenergyresponseandresolutionofhadrontilecalorimeter
AT budagovja effectonahadronshowerleakageontheenergyresponseandresolutionofhadrontilecalorimeter
AT vinogradovvb effectonahadronshowerleakageontheenergyresponseandresolutionofhadrontilecalorimeter
AT karapetiang effectonahadronshowerleakageontheenergyresponseandresolutionofhadrontilecalorimeter
AT nessim effectonahadronshowerleakageontheenergyresponseandresolutionofhadrontilecalorimeter
AT bogushaa effectonahadronshowerleakageontheenergyresponseandresolutionofhadrontilecalorimeter