Cargando…
Development of a TPC detector for the ALICE experiment
A proportional chamber with ring cathode readout is foreseen for the ALICE Time Projection Chamber. It offers low gas gainoperation, light-weight construction and good pulse shape. The Tape Automatic Bonding (TAB) process makes it possible tomount the VLSI analog front end electronics directly on th...
Autores principales: | , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1998
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(97)91246-8 http://cds.cern.ch/record/384754 |
_version_ | 1780893550522662912 |
---|---|
author | Bächler, J Bracinik, J Fischer, H G Flammier, M Janik, R Legrand, J C Musa, L Pikna, M Sitár, B Szymanski, P |
author_facet | Bächler, J Bracinik, J Fischer, H G Flammier, M Janik, R Legrand, J C Musa, L Pikna, M Sitár, B Szymanski, P |
author_sort | Bächler, J |
collection | CERN |
description | A proportional chamber with ring cathode readout is foreseen for the ALICE Time Projection Chamber. It offers low gas gainoperation, light-weight construction and good pulse shape. The Tape Automatic Bonding (TAB) process makes it possible tomount the VLSI analog front end electronics directly on the back face of the multilayer board carrying the ring cathodeelements, yielding high channel density. At the same time, simulation work is done. Constructionand first results will bepresented. |
id | cern-384754 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1998 |
record_format | invenio |
spelling | cern-3847542019-09-30T06:29:59Zdoi:10.1016/S0168-9002(97)91246-8http://cds.cern.ch/record/384754engBächler, JBracinik, JFischer, H GFlammier, MJanik, RLegrand, J CMusa, LPikna, MSitár, BSzymanski, PDevelopment of a TPC detector for the ALICE experimentDetectors and Experimental TechniquesA proportional chamber with ring cathode readout is foreseen for the ALICE Time Projection Chamber. It offers low gas gainoperation, light-weight construction and good pulse shape. The Tape Automatic Bonding (TAB) process makes it possible tomount the VLSI analog front end electronics directly on the back face of the multilayer board carrying the ring cathodeelements, yielding high channel density. At the same time, simulation work is done. Constructionand first results will bepresented.CERN-ALI-98-15CERN-ALICE-PUB-98-15oai:cds.cern.ch:3847541998-03-02 |
spellingShingle | Detectors and Experimental Techniques Bächler, J Bracinik, J Fischer, H G Flammier, M Janik, R Legrand, J C Musa, L Pikna, M Sitár, B Szymanski, P Development of a TPC detector for the ALICE experiment |
title | Development of a TPC detector for the ALICE experiment |
title_full | Development of a TPC detector for the ALICE experiment |
title_fullStr | Development of a TPC detector for the ALICE experiment |
title_full_unstemmed | Development of a TPC detector for the ALICE experiment |
title_short | Development of a TPC detector for the ALICE experiment |
title_sort | development of a tpc detector for the alice experiment |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(97)91246-8 http://cds.cern.ch/record/384754 |
work_keys_str_mv | AT bachlerj developmentofatpcdetectorforthealiceexperiment AT bracinikj developmentofatpcdetectorforthealiceexperiment AT fischerhg developmentofatpcdetectorforthealiceexperiment AT flammierm developmentofatpcdetectorforthealiceexperiment AT janikr developmentofatpcdetectorforthealiceexperiment AT legrandjc developmentofatpcdetectorforthealiceexperiment AT musal developmentofatpcdetectorforthealiceexperiment AT piknam developmentofatpcdetectorforthealiceexperiment AT sitarb developmentofatpcdetectorforthealiceexperiment AT szymanskip developmentofatpcdetectorforthealiceexperiment |