Cargando…

Real time display of the vertical beam sizes in LEP using the BEXE X-ray detector and fast VME based computers

Fast X-ray detectors based on CdTe photoconductors have been installed in LEP since the beginning of its operation in 1989. The angular divergence of the high energy photons from the synchrotron radiation (x-rays) and the narrow spacing of the 64 photoconductors of the detector allow a good measurem...

Descripción completa

Detalles Bibliográficos
Autores principales: Jones, R, Manarin, A, Pignard, Christian, Rossa, E, Schmickler, Hermann, Sillanoli, M, Surback, G
Lenguaje:eng
Publicado: 1999
Materias:
Acceso en línea:http://cds.cern.ch/record/401972
_version_ 1780894219003494400
author Jones, R
Manarin, A
Pignard, Christian
Rossa, E
Schmickler, Hermann
Sillanoli, M
Surback, G
author_facet Jones, R
Manarin, A
Pignard, Christian
Rossa, E
Schmickler, Hermann
Sillanoli, M
Surback, G
author_sort Jones, R
collection CERN
description Fast X-ray detectors based on CdTe photoconductors have been installed in LEP since the beginning of its operation in 1989. The angular divergence of the high energy photons from the synchrotron radiation (x-rays) and the narrow spacing of the 64 photoconductors of the detector allow a good measurement of vertical beam profiles down to an rms beam size of 300 mm. This paper presents some specific parameters and experimental results of an upgrade program in which the local processing power of the front-end electronics has been increased by a factor 50. Such a powerful tool has allowed a real time display of the time evolution of the vertical beam sizes. An online correlation plot between the electron and positron beam sizes (turn by turn) is also displayed. These online video images are available in the LEP control room and are used in daily operation for luminosity optimisation.
id cern-401972
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1999
record_format invenio
spelling cern-4019722023-05-05T13:07:42Zhttp://cds.cern.ch/record/401972engJones, RManarin, APignard, ChristianRossa, ESchmickler, HermannSillanoli, MSurback, GReal time display of the vertical beam sizes in LEP using the BEXE X-ray detector and fast VME based computersAccelerators and Storage RingsFast X-ray detectors based on CdTe photoconductors have been installed in LEP since the beginning of its operation in 1989. The angular divergence of the high energy photons from the synchrotron radiation (x-rays) and the narrow spacing of the 64 photoconductors of the detector allow a good measurement of vertical beam profiles down to an rms beam size of 300 mm. This paper presents some specific parameters and experimental results of an upgrade program in which the local processing power of the front-end electronics has been increased by a factor 50. Such a powerful tool has allowed a real time display of the time evolution of the vertical beam sizes. An online correlation plot between the electron and positron beam sizes (turn by turn) is also displayed. These online video images are available in the LEP control room and are used in daily operation for luminosity optimisation.CERN-SL-99-056-BIoai:cds.cern.ch:4019721999-09-30
spellingShingle Accelerators and Storage Rings
Jones, R
Manarin, A
Pignard, Christian
Rossa, E
Schmickler, Hermann
Sillanoli, M
Surback, G
Real time display of the vertical beam sizes in LEP using the BEXE X-ray detector and fast VME based computers
title Real time display of the vertical beam sizes in LEP using the BEXE X-ray detector and fast VME based computers
title_full Real time display of the vertical beam sizes in LEP using the BEXE X-ray detector and fast VME based computers
title_fullStr Real time display of the vertical beam sizes in LEP using the BEXE X-ray detector and fast VME based computers
title_full_unstemmed Real time display of the vertical beam sizes in LEP using the BEXE X-ray detector and fast VME based computers
title_short Real time display of the vertical beam sizes in LEP using the BEXE X-ray detector and fast VME based computers
title_sort real time display of the vertical beam sizes in lep using the bexe x-ray detector and fast vme based computers
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/401972
work_keys_str_mv AT jonesr realtimedisplayoftheverticalbeamsizesinlepusingthebexexraydetectorandfastvmebasedcomputers
AT manarina realtimedisplayoftheverticalbeamsizesinlepusingthebexexraydetectorandfastvmebasedcomputers
AT pignardchristian realtimedisplayoftheverticalbeamsizesinlepusingthebexexraydetectorandfastvmebasedcomputers
AT rossae realtimedisplayoftheverticalbeamsizesinlepusingthebexexraydetectorandfastvmebasedcomputers
AT schmicklerhermann realtimedisplayoftheverticalbeamsizesinlepusingthebexexraydetectorandfastvmebasedcomputers
AT sillanolim realtimedisplayoftheverticalbeamsizesinlepusingthebexexraydetectorandfastvmebasedcomputers
AT surbackg realtimedisplayoftheverticalbeamsizesinlepusingthebexexraydetectorandfastvmebasedcomputers