Cargando…

Radiation Heating of Primary Collimators at Ramping

A time-dependent temperature map is derived for the primary jaw of the momentum collimation system during the high transient loss period which is to occur at the beginning of the ramp of acceleration. An adequate margin factor is obtained for a loss of 5% of the nominal stored beam and for the nomin...

Descripción completa

Detalles Bibliográficos
Autores principales: Baishev, I S, Barsukov, A B, Jeanneret, J B
Lenguaje:eng
Publicado: 1999
Materias:
Acceso en línea:http://cds.cern.ch/record/404142
Descripción
Sumario:A time-dependent temperature map is derived for the primary jaw of the momentum collimation system during the high transient loss period which is to occur at the beginning of the ramp of acceleration. An adequate margin factor is obtained for a loss of 5% of the nominal stored beam and for the nominal parabolic ramping curve.