Radiation Heating of Primary Collimators at Ramping
A time-dependent temperature map is derived for the primary jaw of the momentum collimation system during the high transient loss period which is to occur at the beginning of the ramp of acceleration. An adequate margin factor is obtained for a loss of 5% of the nominal stored beam and for the nomin...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
1999
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/404142 |
Sumario: | A time-dependent temperature map is derived for the primary jaw of the momentum collimation system during the high transient loss period which is to occur at the beginning of the ramp of acceleration. An adequate margin factor is obtained for a loss of 5% of the nominal stored beam and for the nominal parabolic ramping curve. |
---|