Cargando…

Rate effects in high-resolution drift chambers

The impact of high counting rates on the spatial resolution of cylindrical drift tubes is investigated in detail and the results are compared with simulations. Electronics effects and space-charge effects are quantitatively analysed. A spatial resolution of $\sigma < 80\,\mu\mathrm{m}$ can be ach...

Descripción completa

Detalles Bibliográficos
Autores principales: Aleksa, Martin, Deile, M, Dubbert, J, Fabjan, Christian Wolfgang, Gruhn, Charles R, Hessey, N P, Riegler, W, Sammer, T
Lenguaje:eng
Publicado: 1999
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-9002(99)01016-5
http://cds.cern.ch/record/406877
_version_ 1780894405070159872
author Aleksa, Martin
Deile, M
Dubbert, J
Fabjan, Christian Wolfgang
Gruhn, Charles R
Hessey, N P
Riegler, W
Sammer, T
author_facet Aleksa, Martin
Deile, M
Dubbert, J
Fabjan, Christian Wolfgang
Gruhn, Charles R
Hessey, N P
Riegler, W
Sammer, T
author_sort Aleksa, Martin
collection CERN
description The impact of high counting rates on the spatial resolution of cylindrical drift tubes is investigated in detail and the results are compared with simulations. Electronics effects and space-charge effects are quantitatively analysed. A spatial resolution of $\sigma < 80\,\mu\mathrm{m}$ can be achieved even at rates as high as 1500\,Hz/cm wire length (300\,kHz per wire).
id cern-406877
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1999
record_format invenio
spelling cern-4068772019-09-30T06:29:59Zdoi:10.1016/S0168-9002(99)01016-5http://cds.cern.ch/record/406877engAleksa, MartinDeile, MDubbert, JFabjan, Christian WolfgangGruhn, Charles RHessey, N PRiegler, WSammer, TRate effects in high-resolution drift chambersDetectors and Experimental TechniquesThe impact of high counting rates on the spatial resolution of cylindrical drift tubes is investigated in detail and the results are compared with simulations. Electronics effects and space-charge effects are quantitatively analysed. A spatial resolution of $\sigma < 80\,\mu\mathrm{m}$ can be achieved even at rates as high as 1500\,Hz/cm wire length (300\,kHz per wire).CERN-EP-99-101oai:cds.cern.ch:4068771999-07-15
spellingShingle Detectors and Experimental Techniques
Aleksa, Martin
Deile, M
Dubbert, J
Fabjan, Christian Wolfgang
Gruhn, Charles R
Hessey, N P
Riegler, W
Sammer, T
Rate effects in high-resolution drift chambers
title Rate effects in high-resolution drift chambers
title_full Rate effects in high-resolution drift chambers
title_fullStr Rate effects in high-resolution drift chambers
title_full_unstemmed Rate effects in high-resolution drift chambers
title_short Rate effects in high-resolution drift chambers
title_sort rate effects in high-resolution drift chambers
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/S0168-9002(99)01016-5
http://cds.cern.ch/record/406877
work_keys_str_mv AT aleksamartin rateeffectsinhighresolutiondriftchambers
AT deilem rateeffectsinhighresolutiondriftchambers
AT dubbertj rateeffectsinhighresolutiondriftchambers
AT fabjanchristianwolfgang rateeffectsinhighresolutiondriftchambers
AT gruhncharlesr rateeffectsinhighresolutiondriftchambers
AT hesseynp rateeffectsinhighresolutiondriftchambers
AT rieglerw rateeffectsinhighresolutiondriftchambers
AT sammert rateeffectsinhighresolutiondriftchambers