Cargando…

Silicon beam telescope for CMS detector tests

A beam telescope providing precision track measurements as reference for other detectors has been upgraded in the CERN H2 test beam. The apparatus was completely rebuilt from the detector wafers and front- end electronics to the data acquisition system. The new detector setup consists of eight 5.6*5...

Descripción completa

Detalles Bibliográficos
Autores principales: Eklund, C, Heikkinen, A M, Honkanen, J A, Karimäki, V, Mäenpää, T, Pietarinen, E, Saarikoski, H, Skog, K, Tuominiemi, Jorma, Tuuva, T
Lenguaje:eng
Publicado: 1999
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-9002(99)00210-7
http://cds.cern.ch/record/409293
_version_ 1780894510231846912
author Eklund, C
Heikkinen, A M
Honkanen, J A
Karimäki, V
Mäenpää, T
Pietarinen, E
Saarikoski, H
Skog, K
Tuominiemi, Jorma
Tuuva, T
author_facet Eklund, C
Heikkinen, A M
Honkanen, J A
Karimäki, V
Mäenpää, T
Pietarinen, E
Saarikoski, H
Skog, K
Tuominiemi, Jorma
Tuuva, T
author_sort Eklund, C
collection CERN
description A beam telescope providing precision track measurements as reference for other detectors has been upgraded in the CERN H2 test beam. The apparatus was completely rebuilt from the detector wafers and front- end electronics to the data acquisition system. The new detector setup consists of eight 5.6*5.6 cm/sup 2/ sized DC coupled silicon microstrip detectors. Typical position resolution values of about 7.5 mu m were measured. Details of the setup are described and results from the recent beam tests are reported. (16 refs).
id cern-409293
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1999
record_format invenio
spelling cern-4092932019-09-30T06:29:59Zdoi:10.1016/S0168-9002(99)00210-7http://cds.cern.ch/record/409293engEklund, CHeikkinen, A MHonkanen, J AKarimäki, VMäenpää, TPietarinen, ESaarikoski, HSkog, KTuominiemi, JormaTuuva, TSilicon beam telescope for CMS detector testsDetectors and Experimental TechniquesA beam telescope providing precision track measurements as reference for other detectors has been upgraded in the CERN H2 test beam. The apparatus was completely rebuilt from the detector wafers and front- end electronics to the data acquisition system. The new detector setup consists of eight 5.6*5.6 cm/sup 2/ sized DC coupled silicon microstrip detectors. Typical position resolution values of about 7.5 mu m were measured. Details of the setup are described and results from the recent beam tests are reported. (16 refs).oai:cds.cern.ch:4092931999
spellingShingle Detectors and Experimental Techniques
Eklund, C
Heikkinen, A M
Honkanen, J A
Karimäki, V
Mäenpää, T
Pietarinen, E
Saarikoski, H
Skog, K
Tuominiemi, Jorma
Tuuva, T
Silicon beam telescope for CMS detector tests
title Silicon beam telescope for CMS detector tests
title_full Silicon beam telescope for CMS detector tests
title_fullStr Silicon beam telescope for CMS detector tests
title_full_unstemmed Silicon beam telescope for CMS detector tests
title_short Silicon beam telescope for CMS detector tests
title_sort silicon beam telescope for cms detector tests
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/S0168-9002(99)00210-7
http://cds.cern.ch/record/409293
work_keys_str_mv AT eklundc siliconbeamtelescopeforcmsdetectortests
AT heikkinenam siliconbeamtelescopeforcmsdetectortests
AT honkanenja siliconbeamtelescopeforcmsdetectortests
AT karimakiv siliconbeamtelescopeforcmsdetectortests
AT maenpaat siliconbeamtelescopeforcmsdetectortests
AT pietarinene siliconbeamtelescopeforcmsdetectortests
AT saarikoskih siliconbeamtelescopeforcmsdetectortests
AT skogk siliconbeamtelescopeforcmsdetectortests
AT tuominiemijorma siliconbeamtelescopeforcmsdetectortests
AT tuuvat siliconbeamtelescopeforcmsdetectortests