One long tie bar broken after 3 days because of hydrogen contamination.
The tie bars have been produced with a high yield strength. As known for these type of high strength bolts, and hydrogen contamination during manufacture or heat treatment could lead to rupture under stress after several days.
Autor principal: | |
---|---|
Publicado: |
2000
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/41254 |
_version_ | 1780874823832961024 |
---|---|
author | H. Gerwig |
author_facet | H. Gerwig |
author_sort | H. Gerwig |
collection | CERN |
description | The tie bars have been produced with a high yield strength. As known for these type of high strength bolts, and hydrogen contamination during manufacture or heat treatment could lead to rupture under stress after several days. |
id | cern-41254 |
institution | Organización Europea para la Investigación Nuclear |
publishDate | 2000 |
record_format | invenio |
spelling | cern-412542019-09-30T06:29:59Zhttp://cds.cern.ch/record/41254H. GerwigOne long tie bar broken after 3 days because of hydrogen contamination.MagnetThe tie bars have been produced with a high yield strength. As known for these type of high strength bolts, and hydrogen contamination during manufacture or heat treatment could lead to rupture under stress after several days.CMS-PHO-MAGNET-2000-033oai:cds.cern.ch:412542000-01-15 |
spellingShingle | Magnet H. Gerwig One long tie bar broken after 3 days because of hydrogen contamination. |
title | One long tie bar broken after 3 days because of hydrogen contamination. |
title_full | One long tie bar broken after 3 days because of hydrogen contamination. |
title_fullStr | One long tie bar broken after 3 days because of hydrogen contamination. |
title_full_unstemmed | One long tie bar broken after 3 days because of hydrogen contamination. |
title_short | One long tie bar broken after 3 days because of hydrogen contamination. |
title_sort | one long tie bar broken after 3 days because of hydrogen contamination. |
topic | Magnet |
url | http://cds.cern.ch/record/41254 |
work_keys_str_mv | AT hgerwig onelongtiebarbrokenafter3daysbecauseofhydrogencontamination |