Cargando…
Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter
A Poisson distribution of number of electrons at the input stages of a photomultiplier has been folded into a Landau-Symon distribution of ionization losses in a plastic scintillator and a distribution of the smallest value out of n detectors was derived analytically for m simultaneous particles. A...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
1974
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/0029-554X(75)90076-2 http://cds.cern.ch/record/417231 |
_version_ | 1780894761153986560 |
---|---|
author | Aderholz, M Lehraus, Ivan Matthewson, R |
author_facet | Aderholz, M Lehraus, Ivan Matthewson, R |
author_sort | Aderholz, M |
collection | CERN |
description | A Poisson distribution of number of electrons at the input stages of a photomultiplier has been folded into a Landau-Symon distribution of ionization losses in a plastic scintillator and a distribution of the smallest value out of n detectors was derived analytically for m simultaneous particles. A group of four identical scintillation counters was constructed and the smallest of the four output pulses was used for selective triggering of the bubble chamber flash with the greater precision engendered by the considerably reduced distribution width. (22 refs). |
id | cern-417231 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1974 |
record_format | invenio |
spelling | cern-4172312019-09-30T06:29:59Zdoi:10.1016/0029-554X(75)90076-2http://cds.cern.ch/record/417231engAderholz, MLehraus, IvanMatthewson, RReduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counterDetectors and Experimental TechniquesNuclear PhysicsA Poisson distribution of number of electrons at the input stages of a photomultiplier has been folded into a Landau-Symon distribution of ionization losses in a plastic scintillator and a distribution of the smallest value out of n detectors was derived analytically for m simultaneous particles. A group of four identical scintillation counters was constructed and the smallest of the four output pulses was used for selective triggering of the bubble chamber flash with the greater precision engendered by the considerably reduced distribution width. (22 refs).CERN-PH-2-BEAM-74-4oai:cds.cern.ch:4172311974-07-24 |
spellingShingle | Detectors and Experimental Techniques Nuclear Physics Aderholz, M Lehraus, Ivan Matthewson, R Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter |
title | Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter |
title_full | Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter |
title_fullStr | Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter |
title_full_unstemmed | Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter |
title_short | Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter |
title_sort | reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter |
topic | Detectors and Experimental Techniques Nuclear Physics |
url | https://dx.doi.org/10.1016/0029-554X(75)90076-2 http://cds.cern.ch/record/417231 |
work_keys_str_mv | AT aderholzm reductionoftheionizationlossdistributionwidthofseveralsimultaneousrelativisticparticlestraversingascintillationcounter AT lehrausivan reductionoftheionizationlossdistributionwidthofseveralsimultaneousrelativisticparticlestraversingascintillationcounter AT matthewsonr reductionoftheionizationlossdistributionwidthofseveralsimultaneousrelativisticparticlestraversingascintillationcounter |