Cargando…

Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter

A Poisson distribution of number of electrons at the input stages of a photomultiplier has been folded into a Landau-Symon distribution of ionization losses in a plastic scintillator and a distribution of the smallest value out of n detectors was derived analytically for m simultaneous particles. A...

Descripción completa

Detalles Bibliográficos
Autores principales: Aderholz, M, Lehraus, Ivan, Matthewson, R
Lenguaje:eng
Publicado: 1974
Materias:
Acceso en línea:https://dx.doi.org/10.1016/0029-554X(75)90076-2
http://cds.cern.ch/record/417231
_version_ 1780894761153986560
author Aderholz, M
Lehraus, Ivan
Matthewson, R
author_facet Aderholz, M
Lehraus, Ivan
Matthewson, R
author_sort Aderholz, M
collection CERN
description A Poisson distribution of number of electrons at the input stages of a photomultiplier has been folded into a Landau-Symon distribution of ionization losses in a plastic scintillator and a distribution of the smallest value out of n detectors was derived analytically for m simultaneous particles. A group of four identical scintillation counters was constructed and the smallest of the four output pulses was used for selective triggering of the bubble chamber flash with the greater precision engendered by the considerably reduced distribution width. (22 refs).
id cern-417231
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1974
record_format invenio
spelling cern-4172312019-09-30T06:29:59Zdoi:10.1016/0029-554X(75)90076-2http://cds.cern.ch/record/417231engAderholz, MLehraus, IvanMatthewson, RReduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counterDetectors and Experimental TechniquesNuclear PhysicsA Poisson distribution of number of electrons at the input stages of a photomultiplier has been folded into a Landau-Symon distribution of ionization losses in a plastic scintillator and a distribution of the smallest value out of n detectors was derived analytically for m simultaneous particles. A group of four identical scintillation counters was constructed and the smallest of the four output pulses was used for selective triggering of the bubble chamber flash with the greater precision engendered by the considerably reduced distribution width. (22 refs).CERN-PH-2-BEAM-74-4oai:cds.cern.ch:4172311974-07-24
spellingShingle Detectors and Experimental Techniques
Nuclear Physics
Aderholz, M
Lehraus, Ivan
Matthewson, R
Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter
title Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter
title_full Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter
title_fullStr Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter
title_full_unstemmed Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter
title_short Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter
title_sort reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter
topic Detectors and Experimental Techniques
Nuclear Physics
url https://dx.doi.org/10.1016/0029-554X(75)90076-2
http://cds.cern.ch/record/417231
work_keys_str_mv AT aderholzm reductionoftheionizationlossdistributionwidthofseveralsimultaneousrelativisticparticlestraversingascintillationcounter
AT lehrausivan reductionoftheionizationlossdistributionwidthofseveralsimultaneousrelativisticparticlestraversingascintillationcounter
AT matthewsonr reductionoftheionizationlossdistributionwidthofseveralsimultaneousrelativisticparticlestraversingascintillationcounter