Cargando…

Measurement and reconstruction of the BEBC magnetic field map

The superconducting magnet of the Big European Bubble Chamber (BEBC) has been excited with currents up to 5035 A corresponding to a magnetic induction of 3.1 Tesla at the center of the chamber. Since one expected that during the charging of the magnet coils long time constant eddy currents would be...

Descripción completa

Detalles Bibliográficos
Autores principales: Häbel, E, Wenninger, Horst, Wittgenstein, F
Lenguaje:eng
Publicado: 1973
Materias:
Acceso en línea:http://cds.cern.ch/record/420255
_version_ 1780894828339396608
author Häbel, E
Wenninger, Horst
Wittgenstein, F
author_facet Häbel, E
Wenninger, Horst
Wittgenstein, F
author_sort Häbel, E
collection CERN
description The superconducting magnet of the Big European Bubble Chamber (BEBC) has been excited with currents up to 5035 A corresponding to a magnetic induction of 3.1 Tesla at the center of the chamber. Since one expected that during the charging of the magnet coils long time constant eddy currents would be induced by the varying radial field components, a system of 181 Hall-probes was installed on the boundary of the chamber body allowing to survey the magnetic field map. This Hall-probe system together with an NMR-probe (nuclear magnetic resonance) enabled us to measure and reconstruct to an accuracy of better than 0.1the field map of BEBC, which in itself is uniform to within 3 191332nside the visible fiducial volume of the Chamber. Direct evidence was also given for field map distortions due to the eddy current field which amounted to about 0.723420f the maximum recorded field values at the chamber center. (7 refs).
id cern-420255
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1973
record_format invenio
spelling cern-4202552019-09-30T06:29:59Zhttp://cds.cern.ch/record/420255engHäbel, EWenninger, HorstWittgenstein, FMeasurement and reconstruction of the BEBC magnetic field mapDetectors and Experimental TechniquesThe superconducting magnet of the Big European Bubble Chamber (BEBC) has been excited with currents up to 5035 A corresponding to a magnetic induction of 3.1 Tesla at the center of the chamber. Since one expected that during the charging of the magnet coils long time constant eddy currents would be induced by the varying radial field components, a system of 181 Hall-probes was installed on the boundary of the chamber body allowing to survey the magnetic field map. This Hall-probe system together with an NMR-probe (nuclear magnetic resonance) enabled us to measure and reconstruct to an accuracy of better than 0.1the field map of BEBC, which in itself is uniform to within 3 191332nside the visible fiducial volume of the Chamber. Direct evidence was also given for field map distortions due to the eddy current field which amounted to about 0.723420f the maximum recorded field values at the chamber center. (7 refs).oai:cds.cern.ch:4202551973
spellingShingle Detectors and Experimental Techniques
Häbel, E
Wenninger, Horst
Wittgenstein, F
Measurement and reconstruction of the BEBC magnetic field map
title Measurement and reconstruction of the BEBC magnetic field map
title_full Measurement and reconstruction of the BEBC magnetic field map
title_fullStr Measurement and reconstruction of the BEBC magnetic field map
title_full_unstemmed Measurement and reconstruction of the BEBC magnetic field map
title_short Measurement and reconstruction of the BEBC magnetic field map
title_sort measurement and reconstruction of the bebc magnetic field map
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/420255
work_keys_str_mv AT habele measurementandreconstructionofthebebcmagneticfieldmap
AT wenningerhorst measurementandreconstructionofthebebcmagneticfieldmap
AT wittgensteinf measurementandreconstructionofthebebcmagneticfieldmap