Cargando…
A liquid scintillator detector with wavelength-shifting fibre readout
A technique based on liquid scintillator with wavelength-shiftingfibre readout is interesting for large-mass neutrino detectors.In this paper we present the first results obtained with a laboratoryprototype assembled at CERN. In the configuration tested, a large light yield has been observed and att...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(00)00463-0 http://cds.cern.ch/record/425782 |
_version_ | 1780895065162383360 |
---|---|
author | Doucet, M Fabre, Jean-Paul Grégoire, G Panman, J Zucchelli, P |
author_facet | Doucet, M Fabre, Jean-Paul Grégoire, G Panman, J Zucchelli, P |
author_sort | Doucet, M |
collection | CERN |
description | A technique based on liquid scintillator with wavelength-shiftingfibre readout is interesting for large-mass neutrino detectors.In this paper we present the first results obtained with a laboratoryprototype assembled at CERN. In the configuration tested, a large light yield has been observed and attenuation lengths of the order of 3.2~m have been measured. As a comparison, we also measured the attenuation length of the fibres in air using the same setup. No significant difference in attenuation length between the fibres in air and in liquid was measured. |
id | cern-425782 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-4257822019-09-30T06:29:59Zdoi:10.1016/S0168-9002(00)00463-0http://cds.cern.ch/record/425782engDoucet, MFabre, Jean-PaulGrégoire, GPanman, JZucchelli, PA liquid scintillator detector with wavelength-shifting fibre readoutDetectors and Experimental TechniquesA technique based on liquid scintillator with wavelength-shiftingfibre readout is interesting for large-mass neutrino detectors.In this paper we present the first results obtained with a laboratoryprototype assembled at CERN. In the configuration tested, a large light yield has been observed and attenuation lengths of the order of 3.2~m have been measured. As a comparison, we also measured the attenuation length of the fibres in air using the same setup. No significant difference in attenuation length between the fibres in air and in liquid was measured.CERN-EP-2000-011oai:cds.cern.ch:4257822000-01-21 |
spellingShingle | Detectors and Experimental Techniques Doucet, M Fabre, Jean-Paul Grégoire, G Panman, J Zucchelli, P A liquid scintillator detector with wavelength-shifting fibre readout |
title | A liquid scintillator detector with wavelength-shifting fibre readout |
title_full | A liquid scintillator detector with wavelength-shifting fibre readout |
title_fullStr | A liquid scintillator detector with wavelength-shifting fibre readout |
title_full_unstemmed | A liquid scintillator detector with wavelength-shifting fibre readout |
title_short | A liquid scintillator detector with wavelength-shifting fibre readout |
title_sort | liquid scintillator detector with wavelength-shifting fibre readout |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(00)00463-0 http://cds.cern.ch/record/425782 |
work_keys_str_mv | AT doucetm aliquidscintillatordetectorwithwavelengthshiftingfibrereadout AT fabrejeanpaul aliquidscintillatordetectorwithwavelengthshiftingfibrereadout AT gregoireg aliquidscintillatordetectorwithwavelengthshiftingfibrereadout AT panmanj aliquidscintillatordetectorwithwavelengthshiftingfibrereadout AT zucchellip aliquidscintillatordetectorwithwavelengthshiftingfibrereadout AT doucetm liquidscintillatordetectorwithwavelengthshiftingfibrereadout AT fabrejeanpaul liquidscintillatordetectorwithwavelengthshiftingfibrereadout AT gregoireg liquidscintillatordetectorwithwavelengthshiftingfibrereadout AT panmanj liquidscintillatordetectorwithwavelengthshiftingfibrereadout AT zucchellip liquidscintillatordetectorwithwavelengthshiftingfibrereadout |