Cargando…
High Resolution Timing of MIPs with RPCs
Proposal of abstract for RPC99, Bari, Italy, 28-29 October 1999. RPCs made with glass and metal electrodes, forming accurately spaced gaps of a few hundred micrometres, have reached timing accuracies below 70 ps with efficiencies above 95<P>This type of detector, operating at atmospheric press...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
1999
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(00)00953-0 http://cds.cern.ch/record/426360 |
_version_ | 1780895093429895168 |
---|---|
author | Fonte, Paulo J R |
author_facet | Fonte, Paulo J R |
author_sort | Fonte, Paulo J R |
collection | CERN |
description | Proposal of abstract for RPC99, Bari, Italy, 28-29 October 1999. RPCs made with glass and metal electrodes, forming accurately spaced gaps of a few hundred micrometres, have reached timing accuracies below 70 ps with efficiencies above 95<P>This type of detector, operating at atmospheric pressure with non-flammable gases, seems well suited for large area TOF sytems, providing performances comparable to the existing scintillator-based TOF technology but with significantly lower price per channel.<P>In this work we describe the principles of operation and the performance of several chamber configurations. |
id | cern-426360 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1999 |
record_format | invenio |
spelling | cern-4263602019-09-30T06:29:59Zdoi:10.1016/S0168-9002(00)00953-0http://cds.cern.ch/record/426360engFonte, Paulo J RHigh Resolution Timing of MIPs with RPCsDetectors and Experimental TechniquesProposal of abstract for RPC99, Bari, Italy, 28-29 October 1999. RPCs made with glass and metal electrodes, forming accurately spaced gaps of a few hundred micrometres, have reached timing accuracies below 70 ps with efficiencies above 95<P>This type of detector, operating at atmospheric pressure with non-flammable gases, seems well suited for large area TOF sytems, providing performances comparable to the existing scintillator-based TOF technology but with significantly lower price per channel.<P>In this work we describe the principles of operation and the performance of several chamber configurations.CERN-ALI-99-30CERN-ALICE-PUB-99-30oai:cds.cern.ch:4263601999-06-14 |
spellingShingle | Detectors and Experimental Techniques Fonte, Paulo J R High Resolution Timing of MIPs with RPCs |
title | High Resolution Timing of MIPs with RPCs |
title_full | High Resolution Timing of MIPs with RPCs |
title_fullStr | High Resolution Timing of MIPs with RPCs |
title_full_unstemmed | High Resolution Timing of MIPs with RPCs |
title_short | High Resolution Timing of MIPs with RPCs |
title_sort | high resolution timing of mips with rpcs |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(00)00953-0 http://cds.cern.ch/record/426360 |
work_keys_str_mv | AT fontepaulojr highresolutiontimingofmipswithrpcs |