Fluorocarbon evaporative cooling developments for the ATLAS pixel and semiconductor tracking detectors
Heat transfer coefficients 2-5.103 Wm-2K-1 have been measured in a 3.6 mm I.D. heated tube dissipating 100 Watts - close to the full equivalent power (~110 W) of a barrel SCT detector "stave" - over a range of power dissipations and mass flows in the above fluids. Aspects of full-scale eva...
Autores principales: | Anderssen, E, Bintinger, D L, Berry, S, Bonneau, P, Bosteels, Michel, Bouvier, P, Cragg, D, English, R, Godlewski, J, Górski, B, Grohmann, S, Hallewell, G D, Hayler, T, Ilie, S, Jones, T, Kadlec, J, Lindsay, S, Miller, W, Niinikoski, T O, Olcese, M, Olszowska, J, Payne, B, Pilling, A, Perrin, E, Sandaker, H, Seytre, J F, Thadome, J, Vacek, V |
---|---|