Cargando…
Synchrotron Radiation-Induced Desorption from a NEG-Coated Vacuum Chamber
When the whole inner surface of a vacuum chamber is coated with a non-evaporable getter film, very low static and dynamic pressures are expected after activation. In an accelerator environment this could result in a longer beam lifetime, in a lower risk of pressure bumps, and in a lower level of bre...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
1999
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/435199 |
_version_ | 1780895392190169088 |
---|---|
author | Chiggiato, P Kersevan, Borut P |
author_facet | Chiggiato, P Kersevan, Borut P |
author_sort | Chiggiato, P |
collection | CERN |
description | When the whole inner surface of a vacuum chamber is coated with a non-evaporable getter film, very low static and dynamic pressures are expected after activation. In an accelerator environment this could result in a longer beam lifetime, in a lower risk of pressure bumps, and in a lower level of bremsstrahlung radiation due to the beam-gas interactions. To substantiate these favourable characteristics a Ti-Zr-V coated stainless steel chamber has been tested on a dedicated beamline at the ESRF. It is shown that a large reduction of the synchrotron radiation-induced desorption occurs after activation. |
id | cern-435199 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1999 |
record_format | invenio |
spelling | cern-4351992019-09-30T06:29:59Zhttp://cds.cern.ch/record/435199engChiggiato, PKersevan, Borut PSynchrotron Radiation-Induced Desorption from a NEG-Coated Vacuum ChamberEngineeringWhen the whole inner surface of a vacuum chamber is coated with a non-evaporable getter film, very low static and dynamic pressures are expected after activation. In an accelerator environment this could result in a longer beam lifetime, in a lower risk of pressure bumps, and in a lower level of bremsstrahlung radiation due to the beam-gas interactions. To substantiate these favourable characteristics a Ti-Zr-V coated stainless steel chamber has been tested on a dedicated beamline at the ESRF. It is shown that a large reduction of the synchrotron radiation-induced desorption occurs after activation.CERN-EST-99-004-SMoai:cds.cern.ch:4351991999-12-15 |
spellingShingle | Engineering Chiggiato, P Kersevan, Borut P Synchrotron Radiation-Induced Desorption from a NEG-Coated Vacuum Chamber |
title | Synchrotron Radiation-Induced Desorption from a NEG-Coated Vacuum Chamber |
title_full | Synchrotron Radiation-Induced Desorption from a NEG-Coated Vacuum Chamber |
title_fullStr | Synchrotron Radiation-Induced Desorption from a NEG-Coated Vacuum Chamber |
title_full_unstemmed | Synchrotron Radiation-Induced Desorption from a NEG-Coated Vacuum Chamber |
title_short | Synchrotron Radiation-Induced Desorption from a NEG-Coated Vacuum Chamber |
title_sort | synchrotron radiation-induced desorption from a neg-coated vacuum chamber |
topic | Engineering |
url | http://cds.cern.ch/record/435199 |
work_keys_str_mv | AT chiggiatop synchrotronradiationinduceddesorptionfromanegcoatedvacuumchamber AT kersevanborutp synchrotronradiationinduceddesorptionfromanegcoatedvacuumchamber |