Cargando…

Synchrotron Radiation-Induced Desorption from a NEG-Coated Vacuum Chamber

When the whole inner surface of a vacuum chamber is coated with a non-evaporable getter film, very low static and dynamic pressures are expected after activation. In an accelerator environment this could result in a longer beam lifetime, in a lower risk of pressure bumps, and in a lower level of bre...

Descripción completa

Detalles Bibliográficos
Autores principales: Chiggiato, P, Kersevan, Borut P
Lenguaje:eng
Publicado: 1999
Materias:
Acceso en línea:http://cds.cern.ch/record/435199
_version_ 1780895392190169088
author Chiggiato, P
Kersevan, Borut P
author_facet Chiggiato, P
Kersevan, Borut P
author_sort Chiggiato, P
collection CERN
description When the whole inner surface of a vacuum chamber is coated with a non-evaporable getter film, very low static and dynamic pressures are expected after activation. In an accelerator environment this could result in a longer beam lifetime, in a lower risk of pressure bumps, and in a lower level of bremsstrahlung radiation due to the beam-gas interactions. To substantiate these favourable characteristics a Ti-Zr-V coated stainless steel chamber has been tested on a dedicated beamline at the ESRF. It is shown that a large reduction of the synchrotron radiation-induced desorption occurs after activation.
id cern-435199
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1999
record_format invenio
spelling cern-4351992019-09-30T06:29:59Zhttp://cds.cern.ch/record/435199engChiggiato, PKersevan, Borut PSynchrotron Radiation-Induced Desorption from a NEG-Coated Vacuum ChamberEngineeringWhen the whole inner surface of a vacuum chamber is coated with a non-evaporable getter film, very low static and dynamic pressures are expected after activation. In an accelerator environment this could result in a longer beam lifetime, in a lower risk of pressure bumps, and in a lower level of bremsstrahlung radiation due to the beam-gas interactions. To substantiate these favourable characteristics a Ti-Zr-V coated stainless steel chamber has been tested on a dedicated beamline at the ESRF. It is shown that a large reduction of the synchrotron radiation-induced desorption occurs after activation.CERN-EST-99-004-SMoai:cds.cern.ch:4351991999-12-15
spellingShingle Engineering
Chiggiato, P
Kersevan, Borut P
Synchrotron Radiation-Induced Desorption from a NEG-Coated Vacuum Chamber
title Synchrotron Radiation-Induced Desorption from a NEG-Coated Vacuum Chamber
title_full Synchrotron Radiation-Induced Desorption from a NEG-Coated Vacuum Chamber
title_fullStr Synchrotron Radiation-Induced Desorption from a NEG-Coated Vacuum Chamber
title_full_unstemmed Synchrotron Radiation-Induced Desorption from a NEG-Coated Vacuum Chamber
title_short Synchrotron Radiation-Induced Desorption from a NEG-Coated Vacuum Chamber
title_sort synchrotron radiation-induced desorption from a neg-coated vacuum chamber
topic Engineering
url http://cds.cern.ch/record/435199
work_keys_str_mv AT chiggiatop synchrotronradiationinduceddesorptionfromanegcoatedvacuumchamber
AT kersevanborutp synchrotronradiationinduceddesorptionfromanegcoatedvacuumchamber