Cargando…
Field quality of two 1-m model magnets for LHC low-beta quadrupole magnets
Two 1-m model magnets for the LHC low- beta quadrupoles were constructed and tested in KEK. They were energized to over 240 T/m. The field quality was measured by two harmonic coils. The multipole components were estimated along the straight section and the magnet ends. The results obtained show tha...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/77.828195 http://cds.cern.ch/record/435502 |
_version_ | 1780895401217359872 |
---|---|
author | Ohuchi, N Ajima, Y Qiu, M Nakamoto, T Ogitsu, T Shintomi, T Tsuchiya, K Yamamoto, A |
author_facet | Ohuchi, N Ajima, Y Qiu, M Nakamoto, T Ogitsu, T Shintomi, T Tsuchiya, K Yamamoto, A |
author_sort | Ohuchi, N |
collection | CERN |
description | Two 1-m model magnets for the LHC low- beta quadrupoles were constructed and tested in KEK. They were energized to over 240 T/m. The field quality was measured by two harmonic coils. The multipole components were estimated along the straight section and the magnet ends. The results obtained show that the effect of the thermal cycle on the magnetic field is negligible. The time dependence of the multipole components were also measured at 420 A and it was found that b/sub 6/ changed 0.8 units over 3 hours. This paper describes the magnetic field quality of the two magnets. (6 refs). |
id | cern-435502 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-4355022019-09-30T06:29:59Zdoi:10.1109/77.828195http://cds.cern.ch/record/435502engOhuchi, NAjima, YQiu, MNakamoto, TOgitsu, TShintomi, TTsuchiya, KYamamoto, AField quality of two 1-m model magnets for LHC low-beta quadrupole magnetsAccelerators and Storage RingsTwo 1-m model magnets for the LHC low- beta quadrupoles were constructed and tested in KEK. They were energized to over 240 T/m. The field quality was measured by two harmonic coils. The multipole components were estimated along the straight section and the magnet ends. The results obtained show that the effect of the thermal cycle on the magnetic field is negligible. The time dependence of the multipole components were also measured at 420 A and it was found that b/sub 6/ changed 0.8 units over 3 hours. This paper describes the magnetic field quality of the two magnets. (6 refs).oai:cds.cern.ch:4355022000 |
spellingShingle | Accelerators and Storage Rings Ohuchi, N Ajima, Y Qiu, M Nakamoto, T Ogitsu, T Shintomi, T Tsuchiya, K Yamamoto, A Field quality of two 1-m model magnets for LHC low-beta quadrupole magnets |
title | Field quality of two 1-m model magnets for LHC low-beta quadrupole magnets |
title_full | Field quality of two 1-m model magnets for LHC low-beta quadrupole magnets |
title_fullStr | Field quality of two 1-m model magnets for LHC low-beta quadrupole magnets |
title_full_unstemmed | Field quality of two 1-m model magnets for LHC low-beta quadrupole magnets |
title_short | Field quality of two 1-m model magnets for LHC low-beta quadrupole magnets |
title_sort | field quality of two 1-m model magnets for lhc low-beta quadrupole magnets |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.1109/77.828195 http://cds.cern.ch/record/435502 |
work_keys_str_mv | AT ohuchin fieldqualityoftwo1mmodelmagnetsforlhclowbetaquadrupolemagnets AT ajimay fieldqualityoftwo1mmodelmagnetsforlhclowbetaquadrupolemagnets AT qium fieldqualityoftwo1mmodelmagnetsforlhclowbetaquadrupolemagnets AT nakamotot fieldqualityoftwo1mmodelmagnetsforlhclowbetaquadrupolemagnets AT ogitsut fieldqualityoftwo1mmodelmagnetsforlhclowbetaquadrupolemagnets AT shintomit fieldqualityoftwo1mmodelmagnetsforlhclowbetaquadrupolemagnets AT tsuchiyak fieldqualityoftwo1mmodelmagnetsforlhclowbetaquadrupolemagnets AT yamamotoa fieldqualityoftwo1mmodelmagnetsforlhclowbetaquadrupolemagnets |