Cargando…
Recent developments on ISPA-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ISPA-tube
The Imaging Silicon Pixel Array (ISPA)-tube is a position-sensitive hybrid photon detector. Originally developed for high-energy physics purposes, it has also been used for biomedical applications. Two kinds of ISPA-tube prototypes have been tested successfully in the field of gamma ray imaging. The...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(99)01234-6 http://cds.cern.ch/record/437494 |
_version_ | 1780895479021699072 |
---|---|
author | D'Ambrosio, C De Notaristefani, F Gys, Thierry Leutz, H Piedigrossi, D Puertolas, D Rosso, E |
author_facet | D'Ambrosio, C De Notaristefani, F Gys, Thierry Leutz, H Piedigrossi, D Puertolas, D Rosso, E |
author_sort | D'Ambrosio, C |
collection | CERN |
description | The Imaging Silicon Pixel Array (ISPA)-tube is a position-sensitive hybrid photon detector. Originally developed for high-energy physics purposes, it has also been used for biomedical applications. Two kinds of ISPA-tube prototypes have been tested successfully in the field of gamma ray imaging. The current developments aim at obtaining a detector dedicated to single-photon emission imaging. In this paper, we present the first use in a gamma camera of a new ISPA-tube prototype having an increased active input surface of 40 mm diameter and a de-magnifying electron optics. The quartz input window of the tube is optically coupled to a 3.5 cm/sup 2/ YAlO/sub 3/:Ce detector array with 0.6 mm/sup 2/ single elements. (11 refs). |
id | cern-437494 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-4374942019-09-30T06:29:59Zdoi:10.1016/S0168-9002(99)01234-6http://cds.cern.ch/record/437494engD'Ambrosio, CDe Notaristefani, FGys, ThierryLeutz, HPiedigrossi, DPuertolas, DRosso, ERecent developments on ISPA-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ISPA-tubeDetectors and Experimental TechniquesThe Imaging Silicon Pixel Array (ISPA)-tube is a position-sensitive hybrid photon detector. Originally developed for high-energy physics purposes, it has also been used for biomedical applications. Two kinds of ISPA-tube prototypes have been tested successfully in the field of gamma ray imaging. The current developments aim at obtaining a detector dedicated to single-photon emission imaging. In this paper, we present the first use in a gamma camera of a new ISPA-tube prototype having an increased active input surface of 40 mm diameter and a de-magnifying electron optics. The quartz input window of the tube is optically coupled to a 3.5 cm/sup 2/ YAlO/sub 3/:Ce detector array with 0.6 mm/sup 2/ single elements. (11 refs).oai:cds.cern.ch:4374942000 |
spellingShingle | Detectors and Experimental Techniques D'Ambrosio, C De Notaristefani, F Gys, Thierry Leutz, H Piedigrossi, D Puertolas, D Rosso, E Recent developments on ISPA-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ISPA-tube |
title | Recent developments on ISPA-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ISPA-tube |
title_full | Recent developments on ISPA-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ISPA-tube |
title_fullStr | Recent developments on ISPA-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ISPA-tube |
title_full_unstemmed | Recent developments on ISPA-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ISPA-tube |
title_short | Recent developments on ISPA-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ISPA-tube |
title_sort | recent developments on ispa-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ispa-tube |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(99)01234-6 http://cds.cern.ch/record/437494 |
work_keys_str_mv | AT dambrosioc recentdevelopmentsonispacamerasforgammarayimaginggammaimagingwithanelectrostaticcrossedfocussedispatube AT denotaristefanif recentdevelopmentsonispacamerasforgammarayimaginggammaimagingwithanelectrostaticcrossedfocussedispatube AT gysthierry recentdevelopmentsonispacamerasforgammarayimaginggammaimagingwithanelectrostaticcrossedfocussedispatube AT leutzh recentdevelopmentsonispacamerasforgammarayimaginggammaimagingwithanelectrostaticcrossedfocussedispatube AT piedigrossid recentdevelopmentsonispacamerasforgammarayimaginggammaimagingwithanelectrostaticcrossedfocussedispatube AT puertolasd recentdevelopmentsonispacamerasforgammarayimaginggammaimagingwithanelectrostaticcrossedfocussedispatube AT rossoe recentdevelopmentsonispacamerasforgammarayimaginggammaimagingwithanelectrostaticcrossedfocussedispatube |