Recent developments on ISPA-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ISPA-tube

The Imaging Silicon Pixel Array (ISPA)-tube is a position-sensitive hybrid photon detector. Originally developed for high-energy physics purposes, it has also been used for biomedical applications. Two kinds of ISPA-tube prototypes have been tested successfully in the field of gamma ray imaging. The...

Descripción completa

Detalles Bibliográficos
Autores principales: D'Ambrosio, C, De Notaristefani, F, Gys, Thierry, Leutz, H, Piedigrossi, D, Puertolas, D, Rosso, E
Lenguaje:eng
Publicado: 2000
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-9002(99)01234-6
http://cds.cern.ch/record/437494
_version_ 1780895479021699072
author D'Ambrosio, C
De Notaristefani, F
Gys, Thierry
Leutz, H
Piedigrossi, D
Puertolas, D
Rosso, E
author_facet D'Ambrosio, C
De Notaristefani, F
Gys, Thierry
Leutz, H
Piedigrossi, D
Puertolas, D
Rosso, E
author_sort D'Ambrosio, C
collection CERN
description The Imaging Silicon Pixel Array (ISPA)-tube is a position-sensitive hybrid photon detector. Originally developed for high-energy physics purposes, it has also been used for biomedical applications. Two kinds of ISPA-tube prototypes have been tested successfully in the field of gamma ray imaging. The current developments aim at obtaining a detector dedicated to single-photon emission imaging. In this paper, we present the first use in a gamma camera of a new ISPA-tube prototype having an increased active input surface of 40 mm diameter and a de-magnifying electron optics. The quartz input window of the tube is optically coupled to a 3.5 cm/sup 2/ YAlO/sub 3/:Ce detector array with 0.6 mm/sup 2/ single elements. (11 refs).
id cern-437494
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2000
record_format invenio
spelling cern-4374942019-09-30T06:29:59Zdoi:10.1016/S0168-9002(99)01234-6http://cds.cern.ch/record/437494engD'Ambrosio, CDe Notaristefani, FGys, ThierryLeutz, HPiedigrossi, DPuertolas, DRosso, ERecent developments on ISPA-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ISPA-tubeDetectors and Experimental TechniquesThe Imaging Silicon Pixel Array (ISPA)-tube is a position-sensitive hybrid photon detector. Originally developed for high-energy physics purposes, it has also been used for biomedical applications. Two kinds of ISPA-tube prototypes have been tested successfully in the field of gamma ray imaging. The current developments aim at obtaining a detector dedicated to single-photon emission imaging. In this paper, we present the first use in a gamma camera of a new ISPA-tube prototype having an increased active input surface of 40 mm diameter and a de-magnifying electron optics. The quartz input window of the tube is optically coupled to a 3.5 cm/sup 2/ YAlO/sub 3/:Ce detector array with 0.6 mm/sup 2/ single elements. (11 refs).oai:cds.cern.ch:4374942000
spellingShingle Detectors and Experimental Techniques
D'Ambrosio, C
De Notaristefani, F
Gys, Thierry
Leutz, H
Piedigrossi, D
Puertolas, D
Rosso, E
Recent developments on ISPA-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ISPA-tube
title Recent developments on ISPA-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ISPA-tube
title_full Recent developments on ISPA-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ISPA-tube
title_fullStr Recent developments on ISPA-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ISPA-tube
title_full_unstemmed Recent developments on ISPA-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ISPA-tube
title_short Recent developments on ISPA-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ISPA-tube
title_sort recent developments on ispa-cameras for gamma ray imaging: gamma imaging with an electrostatic crossed focussed ispa-tube
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/S0168-9002(99)01234-6
http://cds.cern.ch/record/437494
work_keys_str_mv AT dambrosioc recentdevelopmentsonispacamerasforgammarayimaginggammaimagingwithanelectrostaticcrossedfocussedispatube
AT denotaristefanif recentdevelopmentsonispacamerasforgammarayimaginggammaimagingwithanelectrostaticcrossedfocussedispatube
AT gysthierry recentdevelopmentsonispacamerasforgammarayimaginggammaimagingwithanelectrostaticcrossedfocussedispatube
AT leutzh recentdevelopmentsonispacamerasforgammarayimaginggammaimagingwithanelectrostaticcrossedfocussedispatube
AT piedigrossid recentdevelopmentsonispacamerasforgammarayimaginggammaimagingwithanelectrostaticcrossedfocussedispatube
AT puertolasd recentdevelopmentsonispacamerasforgammarayimaginggammaimagingwithanelectrostaticcrossedfocussedispatube
AT rossoe recentdevelopmentsonispacamerasforgammarayimaginggammaimagingwithanelectrostaticcrossedfocussedispatube