High resolution micro-pattern gaseous tracking detectors
Micro-strip gas chambers have excellent localization properties, high rate capability and good granularity, and have been adopted for may experimental set-ups. Two recurrent problems hower have been reported: slow degradation under sustained irradiation, and damaging accidental discharges. New breed...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0375-9474(99)00772-1 http://cds.cern.ch/record/444995 |
_version_ | 1780895885527351296 |
---|---|
author | Bachmann, S Bressan, A Ropelewski, Leszek Sauli, Fabio |
author_facet | Bachmann, S Bressan, A Ropelewski, Leszek Sauli, Fabio |
author_sort | Bachmann, S |
collection | CERN |
description | Micro-strip gas chambers have excellent localization properties, high rate capability and good granularity, and have been adopted for may experimental set-ups. Two recurrent problems hower have been reported: slow degradation under sustained irradiation, and damaging accidental discharges. New breeds of detectors aim at improving on these crucial points: CAT, micromegas, gas electron multiplier are examples. Very performing, they are more robust and reliable. Two- stage devices, making use of a gas electron multiplier as first element, permit to sustain larger gains in presence of high rates and heavily ionizing tracks. (16 refs). |
id | cern-444995 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-4449952019-09-30T06:29:59Zdoi:10.1016/S0375-9474(99)00772-1http://cds.cern.ch/record/444995engBachmann, SBressan, ARopelewski, LeszekSauli, FabioHigh resolution micro-pattern gaseous tracking detectorsDetectors and Experimental TechniquesMicro-strip gas chambers have excellent localization properties, high rate capability and good granularity, and have been adopted for may experimental set-ups. Two recurrent problems hower have been reported: slow degradation under sustained irradiation, and damaging accidental discharges. New breeds of detectors aim at improving on these crucial points: CAT, micromegas, gas electron multiplier are examples. Very performing, they are more robust and reliable. Two- stage devices, making use of a gas electron multiplier as first element, permit to sustain larger gains in presence of high rates and heavily ionizing tracks. (16 refs).oai:cds.cern.ch:4449952000 |
spellingShingle | Detectors and Experimental Techniques Bachmann, S Bressan, A Ropelewski, Leszek Sauli, Fabio High resolution micro-pattern gaseous tracking detectors |
title | High resolution micro-pattern gaseous tracking detectors |
title_full | High resolution micro-pattern gaseous tracking detectors |
title_fullStr | High resolution micro-pattern gaseous tracking detectors |
title_full_unstemmed | High resolution micro-pattern gaseous tracking detectors |
title_short | High resolution micro-pattern gaseous tracking detectors |
title_sort | high resolution micro-pattern gaseous tracking detectors |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0375-9474(99)00772-1 http://cds.cern.ch/record/444995 |
work_keys_str_mv | AT bachmanns highresolutionmicropatterngaseoustrackingdetectors AT bressana highresolutionmicropatterngaseoustrackingdetectors AT ropelewskileszek highresolutionmicropatterngaseoustrackingdetectors AT saulifabio highresolutionmicropatterngaseoustrackingdetectors |