Cargando…
The NA48 LKr calorimeter readout electronics
The NA48 experiment at the CERN SPS accelerator is making a measurement of the direct CP violation parameter $\epsilon'/\epsilon$ by comparing the four rates of decay of $K_{S}$ and $K_{L}$ into $2\pi^{0}$ and $\pi^{+}\pi^{-}$. To reconstruct the decays into $2\pi^{0}$ the information from the...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/23.846133 http://cds.cern.ch/record/446330 |
_version_ | 1780895963470102528 |
---|---|
author | Gianoli, A Bal, F Barr, C Brodier-Yourstone, P Buchholz, P Ceccucci, Augusto Cerri, C Chlopik, A Constantini, F Fantechi, R Formenti, F Funk, W Giudici, Sergio Gorini, B Guzik, J A Hallgren, Björn I Kozhevnikov, Yu Iwansky, W de La Taille, C Lacourt, A Laverrière, G C Ljuslin, C Mannelli, I Martin-Chassard, G Martini, M Papi, A Seguin-Moreau, N Sozzi, M Tarlé, J C Velasco, M Vossnack, O Wahl, H Ziolkowski, M |
author_facet | Gianoli, A Bal, F Barr, C Brodier-Yourstone, P Buchholz, P Ceccucci, Augusto Cerri, C Chlopik, A Constantini, F Fantechi, R Formenti, F Funk, W Giudici, Sergio Gorini, B Guzik, J A Hallgren, Björn I Kozhevnikov, Yu Iwansky, W de La Taille, C Lacourt, A Laverrière, G C Ljuslin, C Mannelli, I Martin-Chassard, G Martini, M Papi, A Seguin-Moreau, N Sozzi, M Tarlé, J C Velasco, M Vossnack, O Wahl, H Ziolkowski, M |
author_sort | Gianoli, A |
collection | CERN |
description | The NA48 experiment at the CERN SPS accelerator is making a measurement of the direct CP violation parameter $\epsilon'/\epsilon$ by comparing the four rates of decay of $K_{S}$ and $K_{L}$ into $2\pi^{0}$ and $\pi^{+}\pi^{-}$. To reconstruct the decays into $2\pi^{0}$ the information from the almost 13500 channels of a quasi-homogeneous liquid krypton electromagnetic calorimeter is used. The readout electronics of the calorimeter has been designed to provide a dynamic range from a few MeV to about 50 GeV energy deposition per cell, and to sustain a high rate of incident particles. The system is made by cold charge preamplifiers (working at 120 degrees K), low-noise fast shapers followed by digitizer electronics at 40 MHz sampling rate that employs a gain switching technique to expand the dynamic range, where the gain can be selected for each sample individually (i.e. every 25 ns). To reduce the amount of data collected the system contains a zero suppression circuit based on halo expansion. |
id | cern-446330 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-4463302019-09-30T06:29:59Zdoi:10.1109/23.846133http://cds.cern.ch/record/446330engGianoli, ABal, FBarr, CBrodier-Yourstone, PBuchholz, PCeccucci, AugustoCerri, CChlopik, AConstantini, FFantechi, RFormenti, FFunk, WGiudici, SergioGorini, BGuzik, J AHallgren, Björn IKozhevnikov, YuIwansky, Wde La Taille, CLacourt, ALaverrière, G CLjuslin, CMannelli, IMartin-Chassard, GMartini, MPapi, ASeguin-Moreau, NSozzi, MTarlé, J CVelasco, MVossnack, OWahl, HZiolkowski, MThe NA48 LKr calorimeter readout electronicsDetectors and Experimental TechniquesThe NA48 experiment at the CERN SPS accelerator is making a measurement of the direct CP violation parameter $\epsilon'/\epsilon$ by comparing the four rates of decay of $K_{S}$ and $K_{L}$ into $2\pi^{0}$ and $\pi^{+}\pi^{-}$. To reconstruct the decays into $2\pi^{0}$ the information from the almost 13500 channels of a quasi-homogeneous liquid krypton electromagnetic calorimeter is used. The readout electronics of the calorimeter has been designed to provide a dynamic range from a few MeV to about 50 GeV energy deposition per cell, and to sustain a high rate of incident particles. The system is made by cold charge preamplifiers (working at 120 degrees K), low-noise fast shapers followed by digitizer electronics at 40 MHz sampling rate that employs a gain switching technique to expand the dynamic range, where the gain can be selected for each sample individually (i.e. every 25 ns). To reduce the amount of data collected the system contains a zero suppression circuit based on halo expansion.oai:cds.cern.ch:4463302000 |
spellingShingle | Detectors and Experimental Techniques Gianoli, A Bal, F Barr, C Brodier-Yourstone, P Buchholz, P Ceccucci, Augusto Cerri, C Chlopik, A Constantini, F Fantechi, R Formenti, F Funk, W Giudici, Sergio Gorini, B Guzik, J A Hallgren, Björn I Kozhevnikov, Yu Iwansky, W de La Taille, C Lacourt, A Laverrière, G C Ljuslin, C Mannelli, I Martin-Chassard, G Martini, M Papi, A Seguin-Moreau, N Sozzi, M Tarlé, J C Velasco, M Vossnack, O Wahl, H Ziolkowski, M The NA48 LKr calorimeter readout electronics |
title | The NA48 LKr calorimeter readout electronics |
title_full | The NA48 LKr calorimeter readout electronics |
title_fullStr | The NA48 LKr calorimeter readout electronics |
title_full_unstemmed | The NA48 LKr calorimeter readout electronics |
title_short | The NA48 LKr calorimeter readout electronics |
title_sort | na48 lkr calorimeter readout electronics |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1109/23.846133 http://cds.cern.ch/record/446330 |
work_keys_str_mv | AT gianolia thena48lkrcalorimeterreadoutelectronics AT balf thena48lkrcalorimeterreadoutelectronics AT barrc thena48lkrcalorimeterreadoutelectronics AT brodieryourstonep thena48lkrcalorimeterreadoutelectronics AT buchholzp thena48lkrcalorimeterreadoutelectronics AT ceccucciaugusto thena48lkrcalorimeterreadoutelectronics AT cerric thena48lkrcalorimeterreadoutelectronics AT chlopika thena48lkrcalorimeterreadoutelectronics AT constantinif thena48lkrcalorimeterreadoutelectronics AT fantechir thena48lkrcalorimeterreadoutelectronics AT formentif thena48lkrcalorimeterreadoutelectronics AT funkw thena48lkrcalorimeterreadoutelectronics AT giudicisergio thena48lkrcalorimeterreadoutelectronics AT gorinib thena48lkrcalorimeterreadoutelectronics AT guzikja thena48lkrcalorimeterreadoutelectronics AT hallgrenbjorni thena48lkrcalorimeterreadoutelectronics AT kozhevnikovyu thena48lkrcalorimeterreadoutelectronics AT iwanskyw thena48lkrcalorimeterreadoutelectronics AT delataillec thena48lkrcalorimeterreadoutelectronics AT lacourta thena48lkrcalorimeterreadoutelectronics AT laverrieregc thena48lkrcalorimeterreadoutelectronics AT ljuslinc thena48lkrcalorimeterreadoutelectronics AT mannellii thena48lkrcalorimeterreadoutelectronics AT martinchassardg thena48lkrcalorimeterreadoutelectronics AT martinim thena48lkrcalorimeterreadoutelectronics AT papia thena48lkrcalorimeterreadoutelectronics AT seguinmoreaun thena48lkrcalorimeterreadoutelectronics AT sozzim thena48lkrcalorimeterreadoutelectronics AT tarlejc thena48lkrcalorimeterreadoutelectronics AT velascom thena48lkrcalorimeterreadoutelectronics AT vossnacko thena48lkrcalorimeterreadoutelectronics AT wahlh thena48lkrcalorimeterreadoutelectronics AT ziolkowskim thena48lkrcalorimeterreadoutelectronics AT gianolia na48lkrcalorimeterreadoutelectronics AT balf na48lkrcalorimeterreadoutelectronics AT barrc na48lkrcalorimeterreadoutelectronics AT brodieryourstonep na48lkrcalorimeterreadoutelectronics AT buchholzp na48lkrcalorimeterreadoutelectronics AT ceccucciaugusto na48lkrcalorimeterreadoutelectronics AT cerric na48lkrcalorimeterreadoutelectronics AT chlopika na48lkrcalorimeterreadoutelectronics AT constantinif na48lkrcalorimeterreadoutelectronics AT fantechir na48lkrcalorimeterreadoutelectronics AT formentif na48lkrcalorimeterreadoutelectronics AT funkw na48lkrcalorimeterreadoutelectronics AT giudicisergio na48lkrcalorimeterreadoutelectronics AT gorinib na48lkrcalorimeterreadoutelectronics AT guzikja na48lkrcalorimeterreadoutelectronics AT hallgrenbjorni na48lkrcalorimeterreadoutelectronics AT kozhevnikovyu na48lkrcalorimeterreadoutelectronics AT iwanskyw na48lkrcalorimeterreadoutelectronics AT delataillec na48lkrcalorimeterreadoutelectronics AT lacourta na48lkrcalorimeterreadoutelectronics AT laverrieregc na48lkrcalorimeterreadoutelectronics AT ljuslinc na48lkrcalorimeterreadoutelectronics AT mannellii na48lkrcalorimeterreadoutelectronics AT martinchassardg na48lkrcalorimeterreadoutelectronics AT martinim na48lkrcalorimeterreadoutelectronics AT papia na48lkrcalorimeterreadoutelectronics AT seguinmoreaun na48lkrcalorimeterreadoutelectronics AT sozzim na48lkrcalorimeterreadoutelectronics AT tarlejc na48lkrcalorimeterreadoutelectronics AT velascom na48lkrcalorimeterreadoutelectronics AT vossnacko na48lkrcalorimeterreadoutelectronics AT wahlh na48lkrcalorimeterreadoutelectronics AT ziolkowskim na48lkrcalorimeterreadoutelectronics |