A Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution Line
Three pre-series Test Cells of the LHC Cryogenic Distribution Line (QRL) [1], manufactured by three European industrial companies, will be tested in the year 2000 to qualify the design chosen and verify the thermal and mechanical performances. A dedicated test stand (170 m x 13 m) has been built for...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/449264 |
_version_ | 1780896062319362048 |
---|---|
author | Livran, J Mourou, G A Parente, C Riddone, G Rybkowski, D Veillet, N |
author_facet | Livran, J Mourou, G A Parente, C Riddone, G Rybkowski, D Veillet, N |
author_sort | Livran, J |
collection | CERN |
description | Three pre-series Test Cells of the LHC Cryogenic Distribution Line (QRL) [1], manufactured by three European industrial companies, will be tested in the year 2000 to qualify the design chosen and verify the thermal and mechanical performances. A dedicated test stand (170 m x 13 m) has been built for extensive testing and performance assessment of the pre-series units in parallel. They will be fed with saturated liquid helium at 4.2 K supplied by a mobile helium dewar. In addition, LN2 cooled helium will be used for cool-down and thermal shielding. For each of the three pre-series units, a set of end boxes has been designed and manufactured at CERN. This paper presents the layout of the cryogenic system for the pre-series units, the calorimetric methods as well as the results of the thermal calculation of the end box test. |
id | cern-449264 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-4492642023-05-31T13:22:04Zhttp://cds.cern.ch/record/449264engLivran, JMourou, G AParente, CRiddone, GRybkowski, DVeillet, NA Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution LineAccelerators and Storage RingsThree pre-series Test Cells of the LHC Cryogenic Distribution Line (QRL) [1], manufactured by three European industrial companies, will be tested in the year 2000 to qualify the design chosen and verify the thermal and mechanical performances. A dedicated test stand (170 m x 13 m) has been built for extensive testing and performance assessment of the pre-series units in parallel. They will be fed with saturated liquid helium at 4.2 K supplied by a mobile helium dewar. In addition, LN2 cooled helium will be used for cool-down and thermal shielding. For each of the three pre-series units, a set of end boxes has been designed and manufactured at CERN. This paper presents the layout of the cryogenic system for the pre-series units, the calorimetric methods as well as the results of the thermal calculation of the end box test.LHC-Project-Report-380CERN-LHC-Project-Report-380oai:cds.cern.ch:4492642000-07-26 |
spellingShingle | Accelerators and Storage Rings Livran, J Mourou, G A Parente, C Riddone, G Rybkowski, D Veillet, N A Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution Line |
title | A Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution Line |
title_full | A Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution Line |
title_fullStr | A Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution Line |
title_full_unstemmed | A Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution Line |
title_short | A Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution Line |
title_sort | cryogenic test set-up for the qualification of pre-series test cells for the lhc cryogenic distribution line |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/449264 |
work_keys_str_mv | AT livranj acryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline AT mourouga acryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline AT parentec acryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline AT riddoneg acryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline AT rybkowskid acryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline AT veilletn acryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline AT livranj cryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline AT mourouga cryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline AT parentec cryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline AT riddoneg cryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline AT rybkowskid cryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline AT veilletn cryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline |