Cargando…

A Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution Line

Three pre-series Test Cells of the LHC Cryogenic Distribution Line (QRL) [1], manufactured by three European industrial companies, will be tested in the year 2000 to qualify the design chosen and verify the thermal and mechanical performances. A dedicated test stand (170 m x 13 m) has been built for...

Descripción completa

Detalles Bibliográficos
Autores principales: Livran, J, Mourou, G A, Parente, C, Riddone, G, Rybkowski, D, Veillet, N
Lenguaje:eng
Publicado: 2000
Materias:
Acceso en línea:http://cds.cern.ch/record/449264
_version_ 1780896062319362048
author Livran, J
Mourou, G A
Parente, C
Riddone, G
Rybkowski, D
Veillet, N
author_facet Livran, J
Mourou, G A
Parente, C
Riddone, G
Rybkowski, D
Veillet, N
author_sort Livran, J
collection CERN
description Three pre-series Test Cells of the LHC Cryogenic Distribution Line (QRL) [1], manufactured by three European industrial companies, will be tested in the year 2000 to qualify the design chosen and verify the thermal and mechanical performances. A dedicated test stand (170 m x 13 m) has been built for extensive testing and performance assessment of the pre-series units in parallel. They will be fed with saturated liquid helium at 4.2 K supplied by a mobile helium dewar. In addition, LN2 cooled helium will be used for cool-down and thermal shielding. For each of the three pre-series units, a set of end boxes has been designed and manufactured at CERN. This paper presents the layout of the cryogenic system for the pre-series units, the calorimetric methods as well as the results of the thermal calculation of the end box test.
id cern-449264
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2000
record_format invenio
spelling cern-4492642023-05-31T13:22:04Zhttp://cds.cern.ch/record/449264engLivran, JMourou, G AParente, CRiddone, GRybkowski, DVeillet, NA Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution LineAccelerators and Storage RingsThree pre-series Test Cells of the LHC Cryogenic Distribution Line (QRL) [1], manufactured by three European industrial companies, will be tested in the year 2000 to qualify the design chosen and verify the thermal and mechanical performances. A dedicated test stand (170 m x 13 m) has been built for extensive testing and performance assessment of the pre-series units in parallel. They will be fed with saturated liquid helium at 4.2 K supplied by a mobile helium dewar. In addition, LN2 cooled helium will be used for cool-down and thermal shielding. For each of the three pre-series units, a set of end boxes has been designed and manufactured at CERN. This paper presents the layout of the cryogenic system for the pre-series units, the calorimetric methods as well as the results of the thermal calculation of the end box test.LHC-Project-Report-380CERN-LHC-Project-Report-380oai:cds.cern.ch:4492642000-07-26
spellingShingle Accelerators and Storage Rings
Livran, J
Mourou, G A
Parente, C
Riddone, G
Rybkowski, D
Veillet, N
A Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution Line
title A Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution Line
title_full A Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution Line
title_fullStr A Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution Line
title_full_unstemmed A Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution Line
title_short A Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution Line
title_sort cryogenic test set-up for the qualification of pre-series test cells for the lhc cryogenic distribution line
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/449264
work_keys_str_mv AT livranj acryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline
AT mourouga acryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline
AT parentec acryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline
AT riddoneg acryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline
AT rybkowskid acryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline
AT veilletn acryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline
AT livranj cryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline
AT mourouga cryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline
AT parentec cryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline
AT riddoneg cryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline
AT rybkowskid cryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline
AT veilletn cryogenictestsetupforthequalificationofpreseriestestcellsforthelhccryogenicdistributionline