Cargando…

The LEP Energy Spectrometer

The energy of the circulating particles in the LEP storage ring is predicted by a model based on nuclear magnetic resonance (NMR) probes measuring the bending magnetic field. This model is calibrated by the method of resonant depolarisation. Since the latter technique is limited in energy range an i...

Descripción completa

Detalles Bibliográficos
Autor principal: Prochnow, J
Lenguaje:eng
Publicado: CERN 2000
Materias:
Acceso en línea:http://cds.cern.ch/record/452083
_version_ 1780896171188813824
author Prochnow, J
author_facet Prochnow, J
author_sort Prochnow, J
collection CERN
description The energy of the circulating particles in the LEP storage ring is predicted by a model based on nuclear magnetic resonance (NMR) probes measuring the bending magnetic field. This model is calibrated by the method of resonant depolarisation. Since the latter technique is limited in energy range an independent method to confirm the NMR based model is applied. The spectrometer has been installed to determine the beam energy with a relative accuracy of 1 ×10 -4 . It consists of a precisely calibrated bending magnet flanked by six beam position monitors. The beam energy is determined by measuring the deflection angle of the particles and the integrated bending field. In the 1999 LEP operation period the spectrometer was commissioned and the first energy measure-ments in the regime of 90 GeV were performed. A relative scatter of 1 .5 ×10 -4 was observed with no systematic deviation from the energy model. The scatter is expected to be reduced in the 2000 LEP run by minimising several systematic effects of the measurement procedure. Die Energie der im LEP Speicherring zirkulierenden Teilchen wird aus der Messung des Ablenkfeldes mit Hilfe von Kernspinresonanz (KSR) Instrumenten bestimmt. Dieses KSR Modell wird durch die Methode der Resonanten Depolarisation kalibriert. Da Letztere nur einen Teil des LEP Energiebereichs abdeckt, wurde das Spektrometer als eine unabhängige Methode zur Über-pr fung des Modells entwickelt. Es soll die Energie der Teilchen mit einer relativen Genauigkeit von 1 ×10 -4 bestimmen. Das Spektrometer besteht aus einem exakt kalibriertem Ablenkmag-neten und drei Strahl Positions Monitoren auf jeder Seite. Die Energie des Strahls wird aus der Messung des Ablenkwinkels der Teilchen und dem integralen Magnetfeld bestimmt. Während der LEP Operationsperiode 1999 wurde das Spektrometer in Betrieb genommen und die ersten Energiemessungen im Bereich von 90 GeV durchgef hrt. Es wurde eine relative Streuung der Energien von 1 .5 ×10 -4 ohne systematische Abweichungen vom KSR Modell beobachtet. Durch die Minimierung systematischer Effekte bei der Messung wird eine Verringerung der Streuung während der LEP Operationsperiode 2000 erwartet.
id cern-452083
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2000
publisher CERN
record_format invenio
spelling cern-4520832019-09-30T06:29:59Zhttp://cds.cern.ch/record/452083engProchnow, JThe LEP Energy SpectrometerAccelerators and Storage RingsThe energy of the circulating particles in the LEP storage ring is predicted by a model based on nuclear magnetic resonance (NMR) probes measuring the bending magnetic field. This model is calibrated by the method of resonant depolarisation. Since the latter technique is limited in energy range an independent method to confirm the NMR based model is applied. The spectrometer has been installed to determine the beam energy with a relative accuracy of 1 ×10 -4 . It consists of a precisely calibrated bending magnet flanked by six beam position monitors. The beam energy is determined by measuring the deflection angle of the particles and the integrated bending field. In the 1999 LEP operation period the spectrometer was commissioned and the first energy measure-ments in the regime of 90 GeV were performed. A relative scatter of 1 .5 ×10 -4 was observed with no systematic deviation from the energy model. The scatter is expected to be reduced in the 2000 LEP run by minimising several systematic effects of the measurement procedure. Die Energie der im LEP Speicherring zirkulierenden Teilchen wird aus der Messung des Ablenkfeldes mit Hilfe von Kernspinresonanz (KSR) Instrumenten bestimmt. Dieses KSR Modell wird durch die Methode der Resonanten Depolarisation kalibriert. Da Letztere nur einen Teil des LEP Energiebereichs abdeckt, wurde das Spektrometer als eine unabhängige Methode zur Über-pr fung des Modells entwickelt. Es soll die Energie der Teilchen mit einer relativen Genauigkeit von 1 ×10 -4 bestimmen. Das Spektrometer besteht aus einem exakt kalibriertem Ablenkmag-neten und drei Strahl Positions Monitoren auf jeder Seite. Die Energie des Strahls wird aus der Messung des Ablenkwinkels der Teilchen und dem integralen Magnetfeld bestimmt. Während der LEP Operationsperiode 1999 wurde das Spektrometer in Betrieb genommen und die ersten Energiemessungen im Bereich von 90 GeV durchgef hrt. Es wurde eine relative Streuung der Energien von 1 .5 ×10 -4 ohne systematische Abweichungen vom KSR Modell beobachtet. Durch die Minimierung systematischer Effekte bei der Messung wird eine Verringerung der Streuung während der LEP Operationsperiode 2000 erwartet.CERNCERN-THESIS-2000-026oai:cds.cern.ch:4520832000
spellingShingle Accelerators and Storage Rings
Prochnow, J
The LEP Energy Spectrometer
title The LEP Energy Spectrometer
title_full The LEP Energy Spectrometer
title_fullStr The LEP Energy Spectrometer
title_full_unstemmed The LEP Energy Spectrometer
title_short The LEP Energy Spectrometer
title_sort lep energy spectrometer
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/452083
work_keys_str_mv AT prochnowj thelepenergyspectrometer
AT prochnowj lepenergyspectrometer