Cargando…
Luminosity and Beam Measurements used for Performance Optimisation in the LEP Collider
The vertical beam-beam parameter in LEP reached 0.083 in 1999. In order to achieve and maintain this high performance a number of different observables are continuously monitored and optimised. The beam sizes are measured using X-ray detectors and UV telescopes. The luminosity is determined directly...
Autores principales: | , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/453822 |
_version_ | 1780896215738613760 |
---|---|
author | Assmann, R W Berrig, O E Burns, A Dehning, Bernd Ferrari, A Jakob, H Jung, R Manarin, A Rossa, E Schmickler, Hermann Wenninger, J |
author_facet | Assmann, R W Berrig, O E Burns, A Dehning, Bernd Ferrari, A Jakob, H Jung, R Manarin, A Rossa, E Schmickler, Hermann Wenninger, J |
author_sort | Assmann, R W |
collection | CERN |
description | The vertical beam-beam parameter in LEP reached 0.083 in 1999. In order to achieve and maintain this high performance a number of different observables are continuously monitored and optimised. The beam sizes are measured using X-ray detectors and UV telescopes. The luminosity is determined directly with tungsten-silicon calorimeters and indirectly through an accurate measurement of the beam lifetime. The tune shift is measured from the tune spectrum in collision. Beam-beam deflection scans provide information about the beam sizes and separation at the interaction points. The different measurements are shortly reviewed and their resolution and time response is analysed. Their use for the optimisation of LEP is described. |
id | cern-453822 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-4538222023-05-05T13:07:55Zhttp://cds.cern.ch/record/453822engAssmann, R WBerrig, O EBurns, ADehning, BerndFerrari, AJakob, HJung, RManarin, ARossa, ESchmickler, HermannWenninger, JLuminosity and Beam Measurements used for Performance Optimisation in the LEP ColliderAccelerators and Storage RingsThe vertical beam-beam parameter in LEP reached 0.083 in 1999. In order to achieve and maintain this high performance a number of different observables are continuously monitored and optimised. The beam sizes are measured using X-ray detectors and UV telescopes. The luminosity is determined directly with tungsten-silicon calorimeters and indirectly through an accurate measurement of the beam lifetime. The tune shift is measured from the tune spectrum in collision. Beam-beam deflection scans provide information about the beam sizes and separation at the interaction points. The different measurements are shortly reviewed and their resolution and time response is analysed. Their use for the optimisation of LEP is described.CERN-SL-2000-047-OPoai:cds.cern.ch:4538222000-06-30 |
spellingShingle | Accelerators and Storage Rings Assmann, R W Berrig, O E Burns, A Dehning, Bernd Ferrari, A Jakob, H Jung, R Manarin, A Rossa, E Schmickler, Hermann Wenninger, J Luminosity and Beam Measurements used for Performance Optimisation in the LEP Collider |
title | Luminosity and Beam Measurements used for Performance Optimisation in the LEP Collider |
title_full | Luminosity and Beam Measurements used for Performance Optimisation in the LEP Collider |
title_fullStr | Luminosity and Beam Measurements used for Performance Optimisation in the LEP Collider |
title_full_unstemmed | Luminosity and Beam Measurements used for Performance Optimisation in the LEP Collider |
title_short | Luminosity and Beam Measurements used for Performance Optimisation in the LEP Collider |
title_sort | luminosity and beam measurements used for performance optimisation in the lep collider |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/453822 |
work_keys_str_mv | AT assmannrw luminosityandbeammeasurementsusedforperformanceoptimisationinthelepcollider AT berrigoe luminosityandbeammeasurementsusedforperformanceoptimisationinthelepcollider AT burnsa luminosityandbeammeasurementsusedforperformanceoptimisationinthelepcollider AT dehningbernd luminosityandbeammeasurementsusedforperformanceoptimisationinthelepcollider AT ferraria luminosityandbeammeasurementsusedforperformanceoptimisationinthelepcollider AT jakobh luminosityandbeammeasurementsusedforperformanceoptimisationinthelepcollider AT jungr luminosityandbeammeasurementsusedforperformanceoptimisationinthelepcollider AT manarina luminosityandbeammeasurementsusedforperformanceoptimisationinthelepcollider AT rossae luminosityandbeammeasurementsusedforperformanceoptimisationinthelepcollider AT schmicklerhermann luminosityandbeammeasurementsusedforperformanceoptimisationinthelepcollider AT wenningerj luminosityandbeammeasurementsusedforperformanceoptimisationinthelepcollider |