Performance of a 256 pad hybrid photon detector for ring imaging
We report a detailed experimental investigation of a proximity focused JiIPD with 256 pads of 4 x 4 mm2 for applications on RICH detectors. A signal to noise ratio of 16 is obtained for single photoelectrons with a low noise (ENC I 200 e) front-end electronics and 15.7 kV acceleration voltage. A sin...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1996
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(96)01202-8 http://cds.cern.ch/record/457840 |
_version_ | 1780896314595213312 |
---|---|
author | Chesi, Enrico Guido Martinengo, P Roe, S Weilhammer, Peter Jobez, J P Séguinot, Jacques Ypsilantis, Thomas Dulinski, W |
author_facet | Chesi, Enrico Guido Martinengo, P Roe, S Weilhammer, Peter Jobez, J P Séguinot, Jacques Ypsilantis, Thomas Dulinski, W |
author_sort | Chesi, Enrico Guido |
collection | CERN |
description | We report a detailed experimental investigation of a proximity focused JiIPD with 256 pads of 4 x 4 mm2 for applications on RICH detectors. A signal to noise ratio of 16 is obtained for single photoelectrons with a low noise (ENC I 200 e) front-end electronics and 15.7 kV acceleration voltage. A single photoelectron detection efficiency of 95% is achieved with about 1% bias from electron back scattering. |
id | cern-457840 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1996 |
record_format | invenio |
spelling | cern-4578402019-09-30T06:29:59Zdoi:10.1016/S0168-9002(96)01202-8http://cds.cern.ch/record/457840engChesi, Enrico GuidoMartinengo, PRoe, SWeilhammer, PeterJobez, J PSéguinot, JacquesYpsilantis, ThomasDulinski, WPerformance of a 256 pad hybrid photon detector for ring imagingDetectors and Experimental TechniquesWe report a detailed experimental investigation of a proximity focused JiIPD with 256 pads of 4 x 4 mm2 for applications on RICH detectors. A signal to noise ratio of 16 is obtained for single photoelectrons with a low noise (ENC I 200 e) front-end electronics and 15.7 kV acceleration voltage. A single photoelectron detection efficiency of 95% is achieved with about 1% bias from electron back scattering.LHCb-96-006oai:cds.cern.ch:4578401996-10-15 |
spellingShingle | Detectors and Experimental Techniques Chesi, Enrico Guido Martinengo, P Roe, S Weilhammer, Peter Jobez, J P Séguinot, Jacques Ypsilantis, Thomas Dulinski, W Performance of a 256 pad hybrid photon detector for ring imaging |
title | Performance of a 256 pad hybrid photon detector for ring imaging |
title_full | Performance of a 256 pad hybrid photon detector for ring imaging |
title_fullStr | Performance of a 256 pad hybrid photon detector for ring imaging |
title_full_unstemmed | Performance of a 256 pad hybrid photon detector for ring imaging |
title_short | Performance of a 256 pad hybrid photon detector for ring imaging |
title_sort | performance of a 256 pad hybrid photon detector for ring imaging |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(96)01202-8 http://cds.cern.ch/record/457840 |
work_keys_str_mv | AT chesienricoguido performanceofa256padhybridphotondetectorforringimaging AT martinengop performanceofa256padhybridphotondetectorforringimaging AT roes performanceofa256padhybridphotondetectorforringimaging AT weilhammerpeter performanceofa256padhybridphotondetectorforringimaging AT jobezjp performanceofa256padhybridphotondetectorforringimaging AT seguinotjacques performanceofa256padhybridphotondetectorforringimaging AT ypsilantisthomas performanceofa256padhybridphotondetectorforringimaging AT dulinskiw performanceofa256padhybridphotondetectorforringimaging |