Cargando…

Sensitivity and Accuracy of the Systems for the Magnetic Measurements of the LHC Magnets at CERN

Beam optics of the LHC accelerator require stringent control of the field quality of the main dipole and quadrupole magnets. The field quality measurements need challenging accuracy given the small size of the aperture (50 mm) : relative strength of the magnets within 2×10-4, harmonics in the ppm ra...

Descripción completa

Detalles Bibliográficos
Autores principales: Bottura, L, Buzio, M, Schnizer, P, Smirnov, N, Walckiers, L
Lenguaje:eng
Publicado: 2000
Materias:
Acceso en línea:http://cds.cern.ch/record/466532
_version_ 1780896430729199616
author Bottura, L
Buzio, M
Schnizer, P
Smirnov, N
Walckiers, L
author_facet Bottura, L
Buzio, M
Schnizer, P
Smirnov, N
Walckiers, L
author_sort Bottura, L
collection CERN
description Beam optics of the LHC accelerator require stringent control of the field quality of the main dipole and quadrupole magnets. The field quality measurements need challenging accuracy given the small size of the aperture (50 mm) : relative strength of the magnets within 2×10-4, harmonics in the ppm range, axis determination within 0.1 mm, main field direction within 0.2 mrad. We present a detailed analysis of the accuracy and reproducibility obtained with the equipment presently available for the qualification tests of the first series magnets.
id cern-466532
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2000
record_format invenio
spelling cern-4665322023-05-31T13:23:52Zhttp://cds.cern.ch/record/466532engBottura, LBuzio, MSchnizer, PSmirnov, NWalckiers, LSensitivity and Accuracy of the Systems for the Magnetic Measurements of the LHC Magnets at CERNAccelerators and Storage RingsBeam optics of the LHC accelerator require stringent control of the field quality of the main dipole and quadrupole magnets. The field quality measurements need challenging accuracy given the small size of the aperture (50 mm) : relative strength of the magnets within 2×10-4, harmonics in the ppm range, axis determination within 0.1 mm, main field direction within 0.2 mrad. We present a detailed analysis of the accuracy and reproducibility obtained with the equipment presently available for the qualification tests of the first series magnets.LHC-Project-Report-431CERN-LHC-Project-Report-431oai:cds.cern.ch:4665322000-09-23
spellingShingle Accelerators and Storage Rings
Bottura, L
Buzio, M
Schnizer, P
Smirnov, N
Walckiers, L
Sensitivity and Accuracy of the Systems for the Magnetic Measurements of the LHC Magnets at CERN
title Sensitivity and Accuracy of the Systems for the Magnetic Measurements of the LHC Magnets at CERN
title_full Sensitivity and Accuracy of the Systems for the Magnetic Measurements of the LHC Magnets at CERN
title_fullStr Sensitivity and Accuracy of the Systems for the Magnetic Measurements of the LHC Magnets at CERN
title_full_unstemmed Sensitivity and Accuracy of the Systems for the Magnetic Measurements of the LHC Magnets at CERN
title_short Sensitivity and Accuracy of the Systems for the Magnetic Measurements of the LHC Magnets at CERN
title_sort sensitivity and accuracy of the systems for the magnetic measurements of the lhc magnets at cern
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/466532
work_keys_str_mv AT bottural sensitivityandaccuracyofthesystemsforthemagneticmeasurementsofthelhcmagnetsatcern
AT buziom sensitivityandaccuracyofthesystemsforthemagneticmeasurementsofthelhcmagnetsatcern
AT schnizerp sensitivityandaccuracyofthesystemsforthemagneticmeasurementsofthelhcmagnetsatcern
AT smirnovn sensitivityandaccuracyofthesystemsforthemagneticmeasurementsofthelhcmagnetsatcern
AT walckiersl sensitivityandaccuracyofthesystemsforthemagneticmeasurementsofthelhcmagnetsatcern