Cargando…
Liquid Xe homogeneous electromagnetic calorimeter
We constructed a liquid xenon calorimeter with electrodes of multi- parallel plates. This calorimeter is regarded as homogeneous because of thin electrodes and is expected to have an excellent energy resolution of 0.34% for 70 GeV electrons by EGS4 simulation. We tested it for 10-70 GeV electrons at...
Autores principales: | , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(00)00327-2 http://cds.cern.ch/record/477016 |
_version_ | 1780896696135319552 |
---|---|
author | Okada, H Doke, T Kashiwagi, T Kikuchi, J Kobayashi, M Masuda, K Shibamur, E Suzuki, S Takashima, T Terasawa, K |
author_facet | Okada, H Doke, T Kashiwagi, T Kikuchi, J Kobayashi, M Masuda, K Shibamur, E Suzuki, S Takashima, T Terasawa, K |
author_sort | Okada, H |
collection | CERN |
description | We constructed a liquid xenon calorimeter with electrodes of multi- parallel plates. This calorimeter is regarded as homogeneous because of thin electrodes and is expected to have an excellent energy resolution of 0.34% for 70 GeV electrons by EGS4 simulation. We tested it for 10-70 GeV electrons at CERN. The measurements were made without signals from a readout channel at about 4 radiation length lost by failure. By simply summing other signals the energy resolution of 2% (r.m.s.), which includes the beam momentum spread of 0.65%, was obtained for 70 GeV electrons. The signal from the lost channel can be estimated by fitting a build-up curve to the obtained signals for each event. If the correction for the contribution from the lost channel is made by the fitting method, the energy resolution is 0.9%, which is close to the resolution of 0.71% obtained by the simulation. (9 refs). |
id | cern-477016 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-4770162019-09-30T06:29:59Zdoi:10.1016/S0168-9002(00)00327-2http://cds.cern.ch/record/477016engOkada, HDoke, TKashiwagi, TKikuchi, JKobayashi, MMasuda, KShibamur, ESuzuki, STakashima, TTerasawa, KLiquid Xe homogeneous electromagnetic calorimeterDetectors and Experimental TechniquesWe constructed a liquid xenon calorimeter with electrodes of multi- parallel plates. This calorimeter is regarded as homogeneous because of thin electrodes and is expected to have an excellent energy resolution of 0.34% for 70 GeV electrons by EGS4 simulation. We tested it for 10-70 GeV electrons at CERN. The measurements were made without signals from a readout channel at about 4 radiation length lost by failure. By simply summing other signals the energy resolution of 2% (r.m.s.), which includes the beam momentum spread of 0.65%, was obtained for 70 GeV electrons. The signal from the lost channel can be estimated by fitting a build-up curve to the obtained signals for each event. If the correction for the contribution from the lost channel is made by the fitting method, the energy resolution is 0.9%, which is close to the resolution of 0.71% obtained by the simulation. (9 refs).oai:cds.cern.ch:4770162000 |
spellingShingle | Detectors and Experimental Techniques Okada, H Doke, T Kashiwagi, T Kikuchi, J Kobayashi, M Masuda, K Shibamur, E Suzuki, S Takashima, T Terasawa, K Liquid Xe homogeneous electromagnetic calorimeter |
title | Liquid Xe homogeneous electromagnetic calorimeter |
title_full | Liquid Xe homogeneous electromagnetic calorimeter |
title_fullStr | Liquid Xe homogeneous electromagnetic calorimeter |
title_full_unstemmed | Liquid Xe homogeneous electromagnetic calorimeter |
title_short | Liquid Xe homogeneous electromagnetic calorimeter |
title_sort | liquid xe homogeneous electromagnetic calorimeter |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(00)00327-2 http://cds.cern.ch/record/477016 |
work_keys_str_mv | AT okadah liquidxehomogeneouselectromagneticcalorimeter AT doket liquidxehomogeneouselectromagneticcalorimeter AT kashiwagit liquidxehomogeneouselectromagneticcalorimeter AT kikuchij liquidxehomogeneouselectromagneticcalorimeter AT kobayashim liquidxehomogeneouselectromagneticcalorimeter AT masudak liquidxehomogeneouselectromagneticcalorimeter AT shibamure liquidxehomogeneouselectromagneticcalorimeter AT suzukis liquidxehomogeneouselectromagneticcalorimeter AT takashimat liquidxehomogeneouselectromagneticcalorimeter AT terasawak liquidxehomogeneouselectromagneticcalorimeter |