Measurements of Spatial Resolution of ATLAS Pixel Detectors
Standard as well as irradiated silicon pixel detectors developed for the ATLAS experiment were tested in a beam. Digital and analog resolutions were determined comparing the positions measured by a microstrip telescope and by the pixel detector. Digital resolutions of 10 um and analog resolutions of...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(01)00365-5 http://cds.cern.ch/record/481391 |
_version_ | 1780896849720246272 |
---|---|
author | Lari, Tommaso |
author_facet | Lari, Tommaso |
author_sort | Lari, Tommaso |
collection | CERN |
description | Standard as well as irradiated silicon pixel detectors developed for the ATLAS experiment were tested in a beam. Digital and analog resolutions were determined comparing the positions measured by a microstrip telescope and by the pixel detector. Digital resolutions of 10 um and analog resolutions of 6 um (before irradiation) and 10 um (after irradiation) are obtained without subtracting the error on the position determined by the telescope. |
id | cern-481391 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-4813912023-03-14T17:09:22Zdoi:10.1016/S0168-9002(01)00365-5http://cds.cern.ch/record/481391engLari, TommasoMeasurements of Spatial Resolution of ATLAS Pixel DetectorsDetectors and Experimental TechniquesStandard as well as irradiated silicon pixel detectors developed for the ATLAS experiment were tested in a beam. Digital and analog resolutions were determined comparing the positions measured by a microstrip telescope and by the pixel detector. Digital resolutions of 10 um and analog resolutions of 6 um (before irradiation) and 10 um (after irradiation) are obtained without subtracting the error on the position determined by the telescope.Standard as well as irradiated silicon pixel detectors developed for the ATLAS experiment were tested in a beam. Digital and analog resolutions were determined comparing the positions measured by a microstrip telescope and by the pixel detector. Digital resolutions of 10 um and analog resolutions of 6 um (before irradiation) and 10 um (after irradiation) are obtained without subtracting the error on the position determined by the telescope.physics/0012046CERN-OPEN-2000-345CERN-OPEN-2000-345oai:cds.cern.ch:4813912000-09-08 |
spellingShingle | Detectors and Experimental Techniques Lari, Tommaso Measurements of Spatial Resolution of ATLAS Pixel Detectors |
title | Measurements of Spatial Resolution of ATLAS Pixel Detectors |
title_full | Measurements of Spatial Resolution of ATLAS Pixel Detectors |
title_fullStr | Measurements of Spatial Resolution of ATLAS Pixel Detectors |
title_full_unstemmed | Measurements of Spatial Resolution of ATLAS Pixel Detectors |
title_short | Measurements of Spatial Resolution of ATLAS Pixel Detectors |
title_sort | measurements of spatial resolution of atlas pixel detectors |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(01)00365-5 http://cds.cern.ch/record/481391 |
work_keys_str_mv | AT laritommaso measurementsofspatialresolutionofatlaspixeldetectors |