Cargando…

Measurements of Spatial Resolution of ATLAS Pixel Detectors

Standard as well as irradiated silicon pixel detectors developed for the ATLAS experiment were tested in a beam. Digital and analog resolutions were determined comparing the positions measured by a microstrip telescope and by the pixel detector. Digital resolutions of 10 um and analog resolutions of...

Descripción completa

Detalles Bibliográficos
Autor principal: Lari, Tommaso
Lenguaje:eng
Publicado: 2000
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-9002(01)00365-5
http://cds.cern.ch/record/481391
_version_ 1780896849720246272
author Lari, Tommaso
author_facet Lari, Tommaso
author_sort Lari, Tommaso
collection CERN
description Standard as well as irradiated silicon pixel detectors developed for the ATLAS experiment were tested in a beam. Digital and analog resolutions were determined comparing the positions measured by a microstrip telescope and by the pixel detector. Digital resolutions of 10 um and analog resolutions of 6 um (before irradiation) and 10 um (after irradiation) are obtained without subtracting the error on the position determined by the telescope.
id cern-481391
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2000
record_format invenio
spelling cern-4813912023-03-14T17:09:22Zdoi:10.1016/S0168-9002(01)00365-5http://cds.cern.ch/record/481391engLari, TommasoMeasurements of Spatial Resolution of ATLAS Pixel DetectorsDetectors and Experimental TechniquesStandard as well as irradiated silicon pixel detectors developed for the ATLAS experiment were tested in a beam. Digital and analog resolutions were determined comparing the positions measured by a microstrip telescope and by the pixel detector. Digital resolutions of 10 um and analog resolutions of 6 um (before irradiation) and 10 um (after irradiation) are obtained without subtracting the error on the position determined by the telescope.Standard as well as irradiated silicon pixel detectors developed for the ATLAS experiment were tested in a beam. Digital and analog resolutions were determined comparing the positions measured by a microstrip telescope and by the pixel detector. Digital resolutions of 10 um and analog resolutions of 6 um (before irradiation) and 10 um (after irradiation) are obtained without subtracting the error on the position determined by the telescope.physics/0012046CERN-OPEN-2000-345CERN-OPEN-2000-345oai:cds.cern.ch:4813912000-09-08
spellingShingle Detectors and Experimental Techniques
Lari, Tommaso
Measurements of Spatial Resolution of ATLAS Pixel Detectors
title Measurements of Spatial Resolution of ATLAS Pixel Detectors
title_full Measurements of Spatial Resolution of ATLAS Pixel Detectors
title_fullStr Measurements of Spatial Resolution of ATLAS Pixel Detectors
title_full_unstemmed Measurements of Spatial Resolution of ATLAS Pixel Detectors
title_short Measurements of Spatial Resolution of ATLAS Pixel Detectors
title_sort measurements of spatial resolution of atlas pixel detectors
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/S0168-9002(01)00365-5
http://cds.cern.ch/record/481391
work_keys_str_mv AT laritommaso measurementsofspatialresolutionofatlaspixeldetectors