Comparative evaluation of scatter correction techniques in 3D positron emission tomography
Much research and development has been concentrated on the scatter compensation required for quantitative 3D PET. Increasingly sophisticated scatter correction procedures are under investigation, particularly those based on accurate scatter models, and iterative reconstruction-based scatter compensa...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/484279 |
Sumario: | Much research and development has been concentrated on the scatter compensation required for quantitative 3D PET. Increasingly sophisticated scatter correction procedures are under investigation, particularly those based on accurate scatter models, and iterative reconstruction-based scatter compensation approaches. The main difference among the correction methods is the way in which the scatter component in the selected energy window is estimated. Monte Carlo methods give further insight and might in themselves offer a possible correction procedure. Methods: Five scatter correction methods are compared in this paper where applicable. The dual-energy window (DEW) technique, the convolution-subtraction (CVS) method, two variants of the Monte Carlo-based scatter correction technique (MCBSC1 and MCBSC2) and our newly developed statistical reconstruction-based scatter correction (SRBSC) method. These scatter correction techniques are evaluated using Monte Carlo simulation studies, experimental phantom measurements, and clinical studies. Accurate Monte Carlo modelling is still the gold standard since it allows to separate scattered and unscattered events and compare the estimated and true unscattered component. Results: In this study, our modified version of Monte Carlo-based scatter correction (MCBSC2) seems to provide a good contrast recovery on the simulated Utah phantom, while the DEW method was found to be clearly superior for the experimental phantom studies in terms of quantitative accuracy at the expense of a significant deterioration of the signal-to-noise ratio. On the other hand, the immunity to noise in emission data of statistical reconstruction-based scatter correction methods make them particularly applicable to low-count emission studies. All scatter correction methods give very good activity recovery values for the simulated 3D Hoffman brain phantom which average within 3%. The CVS and MCBSC1 techniques tend to overcorrect while SRBSC undercorrects for scatter in most regions of this phantom. Conclusion: It was concluded that all correction methods significantly improved the image quality and contrast compared to the case where no correction is applied. Generally, it was shown that the differences in the estimated scatter distributions did not have a significant impact on the final quantitative results. The DEW method showed the best compromise between ease of implementation and quantitative accuracy, but significantly deteriorates the signal-noise ratio. |
---|