An Object-Oriented Monte Carlo Simulator for 3D Cylindrical PET Tomographs
Monte Carlo simulation is a very powerful tool in understanding performances of positron tomographs as well as in assessing image reconstruction algorithms and their implementaions. We present an object-oriented Monte Carlo simulator developed for 3D positron tomography. Results from phantom simulat...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
1999
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/484282 |
_version_ | 1780896897957888000 |
---|---|
author | Zaidi, H Scheurer, A H Morel, Christian |
author_facet | Zaidi, H Scheurer, A H Morel, Christian |
author_sort | Zaidi, H |
collection | CERN |
description | Monte Carlo simulation is a very powerful tool in understanding performances of positron tomographs as well as in assessing image reconstruction algorithms and their implementaions. We present an object-oriented Monte Carlo simulator developed for 3D positron tomography. Results from phantom simulation studies including absorption and scattering of annihilation photons in the fielf-of-view are presented. Scatter fractions determined from these studies are in good agreement with measured scatter fractions published in the literature. Limitations and future prospects are discussed. |
id | cern-484282 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1999 |
record_format | invenio |
spelling | cern-4842822019-09-30T06:29:59Zhttp://cds.cern.ch/record/484282engZaidi, HScheurer, A HMorel, ChristianAn Object-Oriented Monte Carlo Simulator for 3D Cylindrical PET TomographsXXMonte Carlo simulation is a very powerful tool in understanding performances of positron tomographs as well as in assessing image reconstruction algorithms and their implementaions. We present an object-oriented Monte Carlo simulator developed for 3D positron tomography. Results from phantom simulation studies including absorption and scattering of annihilation photons in the fielf-of-view are presented. Scatter fractions determined from these studies are in good agreement with measured scatter fractions published in the literature. Limitations and future prospects are discussed.EXT-2001-006oai:cds.cern.ch:4842821999-01-01 |
spellingShingle | XX Zaidi, H Scheurer, A H Morel, Christian An Object-Oriented Monte Carlo Simulator for 3D Cylindrical PET Tomographs |
title | An Object-Oriented Monte Carlo Simulator for 3D Cylindrical PET Tomographs |
title_full | An Object-Oriented Monte Carlo Simulator for 3D Cylindrical PET Tomographs |
title_fullStr | An Object-Oriented Monte Carlo Simulator for 3D Cylindrical PET Tomographs |
title_full_unstemmed | An Object-Oriented Monte Carlo Simulator for 3D Cylindrical PET Tomographs |
title_short | An Object-Oriented Monte Carlo Simulator for 3D Cylindrical PET Tomographs |
title_sort | object-oriented monte carlo simulator for 3d cylindrical pet tomographs |
topic | XX |
url | http://cds.cern.ch/record/484282 |
work_keys_str_mv | AT zaidih anobjectorientedmontecarlosimulatorfor3dcylindricalpettomographs AT scheurerah anobjectorientedmontecarlosimulatorfor3dcylindricalpettomographs AT morelchristian anobjectorientedmontecarlosimulatorfor3dcylindricalpettomographs AT zaidih objectorientedmontecarlosimulatorfor3dcylindricalpettomographs AT scheurerah objectorientedmontecarlosimulatorfor3dcylindricalpettomographs AT morelchristian objectorientedmontecarlosimulatorfor3dcylindricalpettomographs |