Cargando…
Synchrotron radiation-induced desorption from a NEG-coated vacuum chamber [of ESRF beamline]
When the whole inner surface of a vacuum chamber is coated with a non-evaporable getter film, very low static and dynamic pressures are expected after activation. In an accelerator environment this could result in a longer beam lifetime, in a lower risk of pressure bumps, and in a lower level of bre...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/502992 |
Sumario: | When the whole inner surface of a vacuum chamber is coated with a non-evaporable getter film, very low static and dynamic pressures are expected after activation. In an accelerator environment this could result in a longer beam lifetime, in a lower risk of pressure bumps, and in a lower level of bremsstrahlung radiation due to the beam-gas interactions. To substantiate these favourable characteristics a Ti- Zr-V coated stainless-steel chamber has been tested on a dedicated beamline at the ESRF. It is shown that a large reduction of the synchrotron radiation-induced desorption occurs after activation. (10 refs). |
---|