Synchrotron radiation-induced desorption from a NEG-coated vacuum chamber [of ESRF beamline]

When the whole inner surface of a vacuum chamber is coated with a non-evaporable getter film, very low static and dynamic pressures are expected after activation. In an accelerator environment this could result in a longer beam lifetime, in a lower risk of pressure bumps, and in a lower level of bre...

Descripción completa

Detalles Bibliográficos
Autores principales: Chiggiato, P, Kersevan, R
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:http://cds.cern.ch/record/502992
Descripción
Sumario:When the whole inner surface of a vacuum chamber is coated with a non-evaporable getter film, very low static and dynamic pressures are expected after activation. In an accelerator environment this could result in a longer beam lifetime, in a lower risk of pressure bumps, and in a lower level of bremsstrahlung radiation due to the beam-gas interactions. To substantiate these favourable characteristics a Ti- Zr-V coated stainless-steel chamber has been tested on a dedicated beamline at the ESRF. It is shown that a large reduction of the synchrotron radiation-induced desorption occurs after activation. (10 refs).