Results of L3 BGO calorimeter calibration using an RFQ accelerator
A novel calibration system based on a radiofrequency-quadrupole (RFQ) accelerator has been installed in the L3 experiment. Radiative capture of 1.85 MeV protons from the RFQ accelerator in a lithium target produces a flux of 17.6 MeV photons which are used to calibrate 11000 crystals of the L3 BGO c...
Autores principales: | , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/23.903855 http://cds.cern.ch/record/503593 |
_version_ | 1780897296197615616 |
---|---|
author | Chaturvedi, U K Favara, A Gataullin, M Gratta, Giorgio Kirkby, D Lu, W Newman, H Shvorob, A V Tully, C Zhu, R |
author_facet | Chaturvedi, U K Favara, A Gataullin, M Gratta, Giorgio Kirkby, D Lu, W Newman, H Shvorob, A V Tully, C Zhu, R |
author_sort | Chaturvedi, U K |
collection | CERN |
description | A novel calibration system based on a radiofrequency-quadrupole (RFQ) accelerator has been installed in the L3 experiment. Radiative capture of 1.85 MeV protons from the RFQ accelerator in a lithium target produces a flux of 17.6 MeV photons which are used to calibrate 11000 crystals of the L3 BGO calorimeter. In this paper we present results of the RFQ run taken in November 1997. A calibration precision of 0.6% was reached in the barrel of the L3 BGO calorimeter, and 0.7% in the BGO endcaps. (8 refs). |
id | cern-503593 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-5035932019-09-30T06:29:59Zdoi:10.1109/23.903855http://cds.cern.ch/record/503593engChaturvedi, U KFavara, AGataullin, MGratta, GiorgioKirkby, DLu, WNewman, HShvorob, A VTully, CZhu, RResults of L3 BGO calorimeter calibration using an RFQ acceleratorDetectors and Experimental TechniquesA novel calibration system based on a radiofrequency-quadrupole (RFQ) accelerator has been installed in the L3 experiment. Radiative capture of 1.85 MeV protons from the RFQ accelerator in a lithium target produces a flux of 17.6 MeV photons which are used to calibrate 11000 crystals of the L3 BGO calorimeter. In this paper we present results of the RFQ run taken in November 1997. A calibration precision of 0.6% was reached in the barrel of the L3 BGO calorimeter, and 0.7% in the BGO endcaps. (8 refs).oai:cds.cern.ch:5035932000 |
spellingShingle | Detectors and Experimental Techniques Chaturvedi, U K Favara, A Gataullin, M Gratta, Giorgio Kirkby, D Lu, W Newman, H Shvorob, A V Tully, C Zhu, R Results of L3 BGO calorimeter calibration using an RFQ accelerator |
title | Results of L3 BGO calorimeter calibration using an RFQ accelerator |
title_full | Results of L3 BGO calorimeter calibration using an RFQ accelerator |
title_fullStr | Results of L3 BGO calorimeter calibration using an RFQ accelerator |
title_full_unstemmed | Results of L3 BGO calorimeter calibration using an RFQ accelerator |
title_short | Results of L3 BGO calorimeter calibration using an RFQ accelerator |
title_sort | results of l3 bgo calorimeter calibration using an rfq accelerator |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1109/23.903855 http://cds.cern.ch/record/503593 |
work_keys_str_mv | AT chaturvediuk resultsofl3bgocalorimetercalibrationusinganrfqaccelerator AT favaraa resultsofl3bgocalorimetercalibrationusinganrfqaccelerator AT gataullinm resultsofl3bgocalorimetercalibrationusinganrfqaccelerator AT grattagiorgio resultsofl3bgocalorimetercalibrationusinganrfqaccelerator AT kirkbyd resultsofl3bgocalorimetercalibrationusinganrfqaccelerator AT luw resultsofl3bgocalorimetercalibrationusinganrfqaccelerator AT newmanh resultsofl3bgocalorimetercalibrationusinganrfqaccelerator AT shvorobav resultsofl3bgocalorimetercalibrationusinganrfqaccelerator AT tullyc resultsofl3bgocalorimetercalibrationusinganrfqaccelerator AT zhur resultsofl3bgocalorimetercalibrationusinganrfqaccelerator |