Cargando…

Some Aspects on Beam Transfer Function Estimates and their Integrations

Longitudinal Beam Transfer Function (BTF) measurements are used to determine the energy spectrum in the CERN PS Booster (PSB), where noise , mainly con-sistingof initial structures of the injected beam, affects the results and particularly causes a Base-Line Offset (BLO). Different signal processing...

Descripción completa

Detalles Bibliográficos
Autor principal: Sjöström, M
Lenguaje:eng
Publicado: 1996
Materias:
Acceso en línea:http://cds.cern.ch/record/503774
_version_ 1780897306091978752
author Sjöström, M
author_facet Sjöström, M
author_sort Sjöström, M
collection CERN
description Longitudinal Beam Transfer Function (BTF) measurements are used to determine the energy spectrum in the CERN PS Booster (PSB), where noise , mainly con-sistingof initial structures of the injected beam, affects the results and particularly causes a Base-Line Offset (BLO). Different signal processing methods and their integration are investigated. processing methods and their integration are investigated. Para-metric estimation methods are shown to give much smaller BLO. Further, mea-surements on a coasting proton beam at injection energy also show that the BLO variance cannot be improved by extended measurement times due to excitation levels. The report also gives some practical aspects of BTF measurements with Prediction Error Methods (PEMs).
id cern-503774
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1996
record_format invenio
spelling cern-5037742021-11-11T09:57:24Zhttp://cds.cern.ch/record/503774engSjöström, MSome Aspects on Beam Transfer Function Estimates and their IntegrationsAccelerators and Storage RingsLongitudinal Beam Transfer Function (BTF) measurements are used to determine the energy spectrum in the CERN PS Booster (PSB), where noise , mainly con-sistingof initial structures of the injected beam, affects the results and particularly causes a Base-Line Offset (BLO). Different signal processing methods and their integration are investigated. processing methods and their integration are investigated. Para-metric estimation methods are shown to give much smaller BLO. Further, mea-surements on a coasting proton beam at injection energy also show that the BLO variance cannot be improved by extended measurement times due to excitation levels. The report also gives some practical aspects of BTF measurements with Prediction Error Methods (PEMs).CERN-PS-96-048oai:cds.cern.ch:5037741996-11-27
spellingShingle Accelerators and Storage Rings
Sjöström, M
Some Aspects on Beam Transfer Function Estimates and their Integrations
title Some Aspects on Beam Transfer Function Estimates and their Integrations
title_full Some Aspects on Beam Transfer Function Estimates and their Integrations
title_fullStr Some Aspects on Beam Transfer Function Estimates and their Integrations
title_full_unstemmed Some Aspects on Beam Transfer Function Estimates and their Integrations
title_short Some Aspects on Beam Transfer Function Estimates and their Integrations
title_sort some aspects on beam transfer function estimates and their integrations
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/503774
work_keys_str_mv AT sjostromm someaspectsonbeamtransferfunctionestimatesandtheirintegrations