Cargando…
The performance of RPCs with bakelite electrodes of resistivity under high radiation fluxes
Three medium-size Resistive Plate Chambers (RPCs) with bakelite electrodes having resistivity of 5*10/sup 8/, 5*10/sup 9/ and 3*10 /sup 10/ Omega cm were tested in the Gamma Irradiation Facility at CERN in 1997, 1998 and 1999. The 2 mm gap modules working in an Inverted Double Gap configuration fill...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(00)00969-4 http://cds.cern.ch/record/504174 |
Sumario: | Three medium-size Resistive Plate Chambers (RPCs) with bakelite electrodes having resistivity of 5*10/sup 8/, 5*10/sup 9/ and 3*10 /sup 10/ Omega cm were tested in the Gamma Irradiation Facility at CERN in 1997, 1998 and 1999. The 2 mm gap modules working in an Inverted Double Gap configuration filled with gas mixtures containing freon C/sub 2/H/sub 2/F/sub 4/ and operated in avalanche mode exhibit wide efficiency plateau, good time resolution and small time walk due to rate variation even at intensities as high as 1 kHz/cm/sup 2//gap of a continuous radiation flux. (8 refs). |
---|