The performance of RPCs with bakelite electrodes of resistivity under high radiation fluxes

Three medium-size Resistive Plate Chambers (RPCs) with bakelite electrodes having resistivity of 5*10/sup 8/, 5*10/sup 9/ and 3*10 /sup 10/ Omega cm were tested in the Gamma Irradiation Facility at CERN in 1997, 1998 and 1999. The 2 mm gap modules working in an Inverted Double Gap configuration fill...

Descripción completa

Detalles Bibliográficos
Autores principales: Cwiok, M, Dominik, Wojciech, Górski, M, Królikowski, J
Lenguaje:eng
Publicado: 2000
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-9002(00)00969-4
http://cds.cern.ch/record/504174
_version_ 1780897326640922624
author Cwiok, M
Dominik, Wojciech
Górski, M
Królikowski, J
author_facet Cwiok, M
Dominik, Wojciech
Górski, M
Królikowski, J
author_sort Cwiok, M
collection CERN
description Three medium-size Resistive Plate Chambers (RPCs) with bakelite electrodes having resistivity of 5*10/sup 8/, 5*10/sup 9/ and 3*10 /sup 10/ Omega cm were tested in the Gamma Irradiation Facility at CERN in 1997, 1998 and 1999. The 2 mm gap modules working in an Inverted Double Gap configuration filled with gas mixtures containing freon C/sub 2/H/sub 2/F/sub 4/ and operated in avalanche mode exhibit wide efficiency plateau, good time resolution and small time walk due to rate variation even at intensities as high as 1 kHz/cm/sup 2//gap of a continuous radiation flux. (8 refs).
id cern-504174
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2000
record_format invenio
spelling cern-5041742019-09-30T06:29:59Zdoi:10.1016/S0168-9002(00)00969-4http://cds.cern.ch/record/504174engCwiok, MDominik, WojciechGórski, MKrólikowski, JThe performance of RPCs with bakelite electrodes of resistivity under high radiation fluxesParticle PhysicsThree medium-size Resistive Plate Chambers (RPCs) with bakelite electrodes having resistivity of 5*10/sup 8/, 5*10/sup 9/ and 3*10 /sup 10/ Omega cm were tested in the Gamma Irradiation Facility at CERN in 1997, 1998 and 1999. The 2 mm gap modules working in an Inverted Double Gap configuration filled with gas mixtures containing freon C/sub 2/H/sub 2/F/sub 4/ and operated in avalanche mode exhibit wide efficiency plateau, good time resolution and small time walk due to rate variation even at intensities as high as 1 kHz/cm/sup 2//gap of a continuous radiation flux. (8 refs).oai:cds.cern.ch:5041742000
spellingShingle Particle Physics
Cwiok, M
Dominik, Wojciech
Górski, M
Królikowski, J
The performance of RPCs with bakelite electrodes of resistivity under high radiation fluxes
title The performance of RPCs with bakelite electrodes of resistivity under high radiation fluxes
title_full The performance of RPCs with bakelite electrodes of resistivity under high radiation fluxes
title_fullStr The performance of RPCs with bakelite electrodes of resistivity under high radiation fluxes
title_full_unstemmed The performance of RPCs with bakelite electrodes of resistivity under high radiation fluxes
title_short The performance of RPCs with bakelite electrodes of resistivity under high radiation fluxes
title_sort performance of rpcs with bakelite electrodes of resistivity under high radiation fluxes
topic Particle Physics
url https://dx.doi.org/10.1016/S0168-9002(00)00969-4
http://cds.cern.ch/record/504174
work_keys_str_mv AT cwiokm theperformanceofrpcswithbakeliteelectrodesofresistivityunderhighradiationfluxes
AT dominikwojciech theperformanceofrpcswithbakeliteelectrodesofresistivityunderhighradiationfluxes
AT gorskim theperformanceofrpcswithbakeliteelectrodesofresistivityunderhighradiationfluxes
AT krolikowskij theperformanceofrpcswithbakeliteelectrodesofresistivityunderhighradiationfluxes
AT cwiokm performanceofrpcswithbakeliteelectrodesofresistivityunderhighradiationfluxes
AT dominikwojciech performanceofrpcswithbakeliteelectrodesofresistivityunderhighradiationfluxes
AT gorskim performanceofrpcswithbakeliteelectrodesofresistivityunderhighradiationfluxes
AT krolikowskij performanceofrpcswithbakeliteelectrodesofresistivityunderhighradiationfluxes