Cargando…
Study on the operational conditions of a double-gap resistive plate chamber for the CMS
We present the results from cosmic ray tests on the forward Resistive Plate Chamber (RPC) for the CMS. Double-gap prototype RPC were built and tested in the Korea Detector Laboratory (KODEL). We found that addition of SF/sub 6/ and water vapor to the tetrafluorethane-based gas mixture was required f...
Autores principales: | , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(00)00957-8 http://cds.cern.ch/record/504180 |
Sumario: | We present the results from cosmic ray tests on the forward Resistive Plate Chamber (RPC) for the CMS. Double-gap prototype RPC were built and tested in the Korea Detector Laboratory (KODEL). We found that addition of SF/sub 6/ and water vapor to the tetrafluorethane-based gas mixture was required for the long-term stable operation of RPC. Efficiency, time resolution as well as cross-talk behavior of the detector were investigated. In addition, we present the temperature and humidity dependence of bulk resistivity of Korean bakelite in detail. (12 refs). |
---|