Study on the operational conditions of a double-gap resistive plate chamber for the CMS
We present the results from cosmic ray tests on the forward Resistive Plate Chamber (RPC) for the CMS. Double-gap prototype RPC were built and tested in the Korea Detector Laboratory (KODEL). We found that addition of SF/sub 6/ and water vapor to the tetrafluorethane-based gas mixture was required f...
Autores principales: | , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(00)00957-8 http://cds.cern.ch/record/504180 |
_version_ | 1780897327706275840 |
---|---|
author | Ahn, S H Amirikas, R Bahk, S Y Baik, K M Gapienko, V A Hong, B Hong, S J Kim, J Y Kim, Y J Kim, Y U Koo, D G Lee, K S Lee, S J Lim, I T Nam, S K Pac, M Y Park, S Rhee, J T Seo, S W Sim, K S |
author_facet | Ahn, S H Amirikas, R Bahk, S Y Baik, K M Gapienko, V A Hong, B Hong, S J Kim, J Y Kim, Y J Kim, Y U Koo, D G Lee, K S Lee, S J Lim, I T Nam, S K Pac, M Y Park, S Rhee, J T Seo, S W Sim, K S |
author_sort | Ahn, S H |
collection | CERN |
description | We present the results from cosmic ray tests on the forward Resistive Plate Chamber (RPC) for the CMS. Double-gap prototype RPC were built and tested in the Korea Detector Laboratory (KODEL). We found that addition of SF/sub 6/ and water vapor to the tetrafluorethane-based gas mixture was required for the long-term stable operation of RPC. Efficiency, time resolution as well as cross-talk behavior of the detector were investigated. In addition, we present the temperature and humidity dependence of bulk resistivity of Korean bakelite in detail. (12 refs). |
id | cern-504180 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-5041802019-09-30T06:29:59Zdoi:10.1016/S0168-9002(00)00957-8http://cds.cern.ch/record/504180engAhn, S HAmirikas, RBahk, S YBaik, K MGapienko, V AHong, BHong, S JKim, J YKim, Y JKim, Y UKoo, D GLee, K SLee, S JLim, I TNam, S KPac, M YPark, SRhee, J TSeo, S WSim, K SStudy on the operational conditions of a double-gap resistive plate chamber for the CMSDetectors and Experimental TechniquesWe present the results from cosmic ray tests on the forward Resistive Plate Chamber (RPC) for the CMS. Double-gap prototype RPC were built and tested in the Korea Detector Laboratory (KODEL). We found that addition of SF/sub 6/ and water vapor to the tetrafluorethane-based gas mixture was required for the long-term stable operation of RPC. Efficiency, time resolution as well as cross-talk behavior of the detector were investigated. In addition, we present the temperature and humidity dependence of bulk resistivity of Korean bakelite in detail. (12 refs).oai:cds.cern.ch:5041802000 |
spellingShingle | Detectors and Experimental Techniques Ahn, S H Amirikas, R Bahk, S Y Baik, K M Gapienko, V A Hong, B Hong, S J Kim, J Y Kim, Y J Kim, Y U Koo, D G Lee, K S Lee, S J Lim, I T Nam, S K Pac, M Y Park, S Rhee, J T Seo, S W Sim, K S Study on the operational conditions of a double-gap resistive plate chamber for the CMS |
title | Study on the operational conditions of a double-gap resistive plate chamber for the CMS |
title_full | Study on the operational conditions of a double-gap resistive plate chamber for the CMS |
title_fullStr | Study on the operational conditions of a double-gap resistive plate chamber for the CMS |
title_full_unstemmed | Study on the operational conditions of a double-gap resistive plate chamber for the CMS |
title_short | Study on the operational conditions of a double-gap resistive plate chamber for the CMS |
title_sort | study on the operational conditions of a double-gap resistive plate chamber for the cms |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(00)00957-8 http://cds.cern.ch/record/504180 |
work_keys_str_mv | AT ahnsh studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT amirikasr studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT bahksy studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT baikkm studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT gapienkova studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT hongb studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT hongsj studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT kimjy studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT kimyj studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT kimyu studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT koodg studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT leeks studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT leesj studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT limit studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT namsk studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT pacmy studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT parks studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT rheejt studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT seosw studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms AT simks studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms |