Cargando…

Study on the operational conditions of a double-gap resistive plate chamber for the CMS

We present the results from cosmic ray tests on the forward Resistive Plate Chamber (RPC) for the CMS. Double-gap prototype RPC were built and tested in the Korea Detector Laboratory (KODEL). We found that addition of SF/sub 6/ and water vapor to the tetrafluorethane-based gas mixture was required f...

Descripción completa

Detalles Bibliográficos
Autores principales: Ahn, S H, Amirikas, R, Bahk, S Y, Baik, K M, Gapienko, V A, Hong, B, Hong, S J, Kim, J Y, Kim, Y J, Kim, Y U, Koo, D G, Lee, K S, Lee, S J, Lim, I T, Nam, S K, Pac, M Y, Park, S, Rhee, J T, Seo, S W, Sim, K S
Lenguaje:eng
Publicado: 2000
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-9002(00)00957-8
http://cds.cern.ch/record/504180
_version_ 1780897327706275840
author Ahn, S H
Amirikas, R
Bahk, S Y
Baik, K M
Gapienko, V A
Hong, B
Hong, S J
Kim, J Y
Kim, Y J
Kim, Y U
Koo, D G
Lee, K S
Lee, S J
Lim, I T
Nam, S K
Pac, M Y
Park, S
Rhee, J T
Seo, S W
Sim, K S
author_facet Ahn, S H
Amirikas, R
Bahk, S Y
Baik, K M
Gapienko, V A
Hong, B
Hong, S J
Kim, J Y
Kim, Y J
Kim, Y U
Koo, D G
Lee, K S
Lee, S J
Lim, I T
Nam, S K
Pac, M Y
Park, S
Rhee, J T
Seo, S W
Sim, K S
author_sort Ahn, S H
collection CERN
description We present the results from cosmic ray tests on the forward Resistive Plate Chamber (RPC) for the CMS. Double-gap prototype RPC were built and tested in the Korea Detector Laboratory (KODEL). We found that addition of SF/sub 6/ and water vapor to the tetrafluorethane-based gas mixture was required for the long-term stable operation of RPC. Efficiency, time resolution as well as cross-talk behavior of the detector were investigated. In addition, we present the temperature and humidity dependence of bulk resistivity of Korean bakelite in detail. (12 refs).
id cern-504180
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2000
record_format invenio
spelling cern-5041802019-09-30T06:29:59Zdoi:10.1016/S0168-9002(00)00957-8http://cds.cern.ch/record/504180engAhn, S HAmirikas, RBahk, S YBaik, K MGapienko, V AHong, BHong, S JKim, J YKim, Y JKim, Y UKoo, D GLee, K SLee, S JLim, I TNam, S KPac, M YPark, SRhee, J TSeo, S WSim, K SStudy on the operational conditions of a double-gap resistive plate chamber for the CMSDetectors and Experimental TechniquesWe present the results from cosmic ray tests on the forward Resistive Plate Chamber (RPC) for the CMS. Double-gap prototype RPC were built and tested in the Korea Detector Laboratory (KODEL). We found that addition of SF/sub 6/ and water vapor to the tetrafluorethane-based gas mixture was required for the long-term stable operation of RPC. Efficiency, time resolution as well as cross-talk behavior of the detector were investigated. In addition, we present the temperature and humidity dependence of bulk resistivity of Korean bakelite in detail. (12 refs).oai:cds.cern.ch:5041802000
spellingShingle Detectors and Experimental Techniques
Ahn, S H
Amirikas, R
Bahk, S Y
Baik, K M
Gapienko, V A
Hong, B
Hong, S J
Kim, J Y
Kim, Y J
Kim, Y U
Koo, D G
Lee, K S
Lee, S J
Lim, I T
Nam, S K
Pac, M Y
Park, S
Rhee, J T
Seo, S W
Sim, K S
Study on the operational conditions of a double-gap resistive plate chamber for the CMS
title Study on the operational conditions of a double-gap resistive plate chamber for the CMS
title_full Study on the operational conditions of a double-gap resistive plate chamber for the CMS
title_fullStr Study on the operational conditions of a double-gap resistive plate chamber for the CMS
title_full_unstemmed Study on the operational conditions of a double-gap resistive plate chamber for the CMS
title_short Study on the operational conditions of a double-gap resistive plate chamber for the CMS
title_sort study on the operational conditions of a double-gap resistive plate chamber for the cms
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/S0168-9002(00)00957-8
http://cds.cern.ch/record/504180
work_keys_str_mv AT ahnsh studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT amirikasr studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT bahksy studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT baikkm studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT gapienkova studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT hongb studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT hongsj studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT kimjy studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT kimyj studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT kimyu studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT koodg studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT leeks studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT leesj studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT limit studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT namsk studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT pacmy studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT parks studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT rheejt studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT seosw studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms
AT simks studyontheoperationalconditionsofadoublegapresistiveplatechamberforthecms