Cargando…

Performance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeter

Nearly 80000 PWO crystals for the CMS electromagnetic calorimeter will arrive at CERN/Geneva and INFN-ENEA/Rome between now and year 2004. The stringent specifications on their dimensions and optical quality have to be verified prior to their formal acceptation. Automatic systems for measuring the c...

Descripción completa

Detalles Bibliográficos
Autores principales: Auffray, Etiennette, Chevenier, G, Freire, M, Lecoq, P, Le Goff, J M, Marcos, R, Drobychev, G Yu, Missevitch, O V, Oskine, A, Zouevski, R F, Peigneux, J P, Schneegans, M
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-9002(00)00665-3
http://cds.cern.ch/record/506633
_version_ 1780897381335695360
author Auffray, Etiennette
Chevenier, G
Freire, M
Lecoq, P
Le Goff, J M
Marcos, R
Drobychev, G Yu
Missevitch, O V
Oskine, A
Zouevski, R F
Peigneux, J P
Schneegans, M
author_facet Auffray, Etiennette
Chevenier, G
Freire, M
Lecoq, P
Le Goff, J M
Marcos, R
Drobychev, G Yu
Missevitch, O V
Oskine, A
Zouevski, R F
Peigneux, J P
Schneegans, M
author_sort Auffray, Etiennette
collection CERN
description Nearly 80000 PWO crystals for the CMS electromagnetic calorimeter will arrive at CERN/Geneva and INFN-ENEA/Rome between now and year 2004. The stringent specifications on their dimensions and optical quality have to be verified prior to their formal acceptation. Automatic systems for measuring the critical parameters of each crystal and recording them in a database have been designed and constructed. The first machine is now in stable operation at CERN. In this note, the performance of each instrument, based on the measurements on ~1000 pre-production crystals, is analysed in terms of stability and compared to the results of conventional benches. (9 refs).
id cern-506633
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2001
record_format invenio
spelling cern-5066332019-09-30T06:29:59Zdoi:10.1016/S0168-9002(00)00665-3http://cds.cern.ch/record/506633engAuffray, EtiennetteChevenier, GFreire, MLecoq, PLe Goff, J MMarcos, RDrobychev, G YuMissevitch, O VOskine, AZouevski, R FPeigneux, J PSchneegans, MPerformance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeterDetectors and Experimental TechniquesNearly 80000 PWO crystals for the CMS electromagnetic calorimeter will arrive at CERN/Geneva and INFN-ENEA/Rome between now and year 2004. The stringent specifications on their dimensions and optical quality have to be verified prior to their formal acceptation. Automatic systems for measuring the critical parameters of each crystal and recording them in a database have been designed and constructed. The first machine is now in stable operation at CERN. In this note, the performance of each instrument, based on the measurements on ~1000 pre-production crystals, is analysed in terms of stability and compared to the results of conventional benches. (9 refs).oai:cds.cern.ch:5066332001
spellingShingle Detectors and Experimental Techniques
Auffray, Etiennette
Chevenier, G
Freire, M
Lecoq, P
Le Goff, J M
Marcos, R
Drobychev, G Yu
Missevitch, O V
Oskine, A
Zouevski, R F
Peigneux, J P
Schneegans, M
Performance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeter
title Performance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeter
title_full Performance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeter
title_fullStr Performance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeter
title_full_unstemmed Performance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeter
title_short Performance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeter
title_sort performance of accos, an automatic crystal quality control system for the pwo crystals of the cms calorimeter
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/S0168-9002(00)00665-3
http://cds.cern.ch/record/506633
work_keys_str_mv AT auffrayetiennette performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter
AT chevenierg performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter
AT freirem performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter
AT lecoqp performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter
AT legoffjm performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter
AT marcosr performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter
AT drobychevgyu performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter
AT missevitchov performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter
AT oskinea performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter
AT zouevskirf performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter
AT peigneuxjp performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter
AT schneegansm performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter