Cargando…
Performance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeter
Nearly 80000 PWO crystals for the CMS electromagnetic calorimeter will arrive at CERN/Geneva and INFN-ENEA/Rome between now and year 2004. The stringent specifications on their dimensions and optical quality have to be verified prior to their formal acceptation. Automatic systems for measuring the c...
Autores principales: | , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(00)00665-3 http://cds.cern.ch/record/506633 |
_version_ | 1780897381335695360 |
---|---|
author | Auffray, Etiennette Chevenier, G Freire, M Lecoq, P Le Goff, J M Marcos, R Drobychev, G Yu Missevitch, O V Oskine, A Zouevski, R F Peigneux, J P Schneegans, M |
author_facet | Auffray, Etiennette Chevenier, G Freire, M Lecoq, P Le Goff, J M Marcos, R Drobychev, G Yu Missevitch, O V Oskine, A Zouevski, R F Peigneux, J P Schneegans, M |
author_sort | Auffray, Etiennette |
collection | CERN |
description | Nearly 80000 PWO crystals for the CMS electromagnetic calorimeter will arrive at CERN/Geneva and INFN-ENEA/Rome between now and year 2004. The stringent specifications on their dimensions and optical quality have to be verified prior to their formal acceptation. Automatic systems for measuring the critical parameters of each crystal and recording them in a database have been designed and constructed. The first machine is now in stable operation at CERN. In this note, the performance of each instrument, based on the measurements on ~1000 pre-production crystals, is analysed in terms of stability and compared to the results of conventional benches. (9 refs). |
id | cern-506633 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2001 |
record_format | invenio |
spelling | cern-5066332019-09-30T06:29:59Zdoi:10.1016/S0168-9002(00)00665-3http://cds.cern.ch/record/506633engAuffray, EtiennetteChevenier, GFreire, MLecoq, PLe Goff, J MMarcos, RDrobychev, G YuMissevitch, O VOskine, AZouevski, R FPeigneux, J PSchneegans, MPerformance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeterDetectors and Experimental TechniquesNearly 80000 PWO crystals for the CMS electromagnetic calorimeter will arrive at CERN/Geneva and INFN-ENEA/Rome between now and year 2004. The stringent specifications on their dimensions and optical quality have to be verified prior to their formal acceptation. Automatic systems for measuring the critical parameters of each crystal and recording them in a database have been designed and constructed. The first machine is now in stable operation at CERN. In this note, the performance of each instrument, based on the measurements on ~1000 pre-production crystals, is analysed in terms of stability and compared to the results of conventional benches. (9 refs).oai:cds.cern.ch:5066332001 |
spellingShingle | Detectors and Experimental Techniques Auffray, Etiennette Chevenier, G Freire, M Lecoq, P Le Goff, J M Marcos, R Drobychev, G Yu Missevitch, O V Oskine, A Zouevski, R F Peigneux, J P Schneegans, M Performance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeter |
title | Performance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeter |
title_full | Performance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeter |
title_fullStr | Performance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeter |
title_full_unstemmed | Performance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeter |
title_short | Performance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeter |
title_sort | performance of accos, an automatic crystal quality control system for the pwo crystals of the cms calorimeter |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(00)00665-3 http://cds.cern.ch/record/506633 |
work_keys_str_mv | AT auffrayetiennette performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter AT chevenierg performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter AT freirem performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter AT lecoqp performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter AT legoffjm performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter AT marcosr performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter AT drobychevgyu performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter AT missevitchov performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter AT oskinea performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter AT zouevskirf performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter AT peigneuxjp performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter AT schneegansm performanceofaccosanautomaticcrystalqualitycontrolsystemforthepwocrystalsofthecmscalorimeter |