Cargando…
Performance of the all-silicon CMS tracker
The Compact Muon Solenoid (CMS) Tracker Collaboration has recently revised the tracking-detector layout. While the previous design relied on Micro Strip Gas Chamber (MSGC) and silicon detectors, the new layout implements solid state sensors as the sole technological choice. The new all-silicon layou...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(01)00121-8 http://cds.cern.ch/record/506641 |
_version_ | 1780897383078428672 |
---|---|
author | Caner, A |
author_facet | Caner, A |
author_sort | Caner, A |
collection | CERN |
description | The Compact Muon Solenoid (CMS) Tracker Collaboration has recently revised the tracking-detector layout. While the previous design relied on Micro Strip Gas Chamber (MSGC) and silicon detectors, the new layout implements solid state sensors as the sole technological choice. The new all-silicon layout is presented and the projected performance is discussed in terms of several benchmark topologies. (5 refs). |
id | cern-506641 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2001 |
record_format | invenio |
spelling | cern-5066412019-09-30T06:29:59Zdoi:10.1016/S0168-9002(01)00121-8http://cds.cern.ch/record/506641engCaner, APerformance of the all-silicon CMS trackerDetectors and Experimental TechniquesThe Compact Muon Solenoid (CMS) Tracker Collaboration has recently revised the tracking-detector layout. While the previous design relied on Micro Strip Gas Chamber (MSGC) and silicon detectors, the new layout implements solid state sensors as the sole technological choice. The new all-silicon layout is presented and the projected performance is discussed in terms of several benchmark topologies. (5 refs).oai:cds.cern.ch:5066412001 |
spellingShingle | Detectors and Experimental Techniques Caner, A Performance of the all-silicon CMS tracker |
title | Performance of the all-silicon CMS tracker |
title_full | Performance of the all-silicon CMS tracker |
title_fullStr | Performance of the all-silicon CMS tracker |
title_full_unstemmed | Performance of the all-silicon CMS tracker |
title_short | Performance of the all-silicon CMS tracker |
title_sort | performance of the all-silicon cms tracker |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(01)00121-8 http://cds.cern.ch/record/506641 |
work_keys_str_mv | AT canera performanceoftheallsiliconcmstracker |