Cargando…

Silicon detector developments for CMS

At the end of 1999, the CMS collaboration decided for a tracking system based entirely on silicon detectors. The all silicon tracker for CMS is a major challenge in terms of performance, scale of the devices and severity of the radiation environment. To fulfill all the requirements, a large program...

Descripción completa

Detalles Bibliográficos
Autor principal: Bellucci, L
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-9002(01)00111-5
http://cds.cern.ch/record/506645
_version_ 1780897383938260992
author Bellucci, L
author_facet Bellucci, L
author_sort Bellucci, L
collection CERN
description At the end of 1999, the CMS collaboration decided for a tracking system based entirely on silicon detectors. The all silicon tracker for CMS is a major challenge in terms of performance, scale of the devices and severity of the radiation environment. To fulfill all the requirements, a large program of study and development in the field of silicon strip detectors has been carried out. The characteristics of silicon microstrip detectors were measured for different strip pitches and various strip implant and metal widths. Devices were investigated before and after irradiation. The optimization of the design parameters and choice of substrate resistivity and crystal orientation are reviewed. (8 refs).
id cern-506645
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2001
record_format invenio
spelling cern-5066452019-09-30T06:29:59Zdoi:10.1016/S0168-9002(01)00111-5http://cds.cern.ch/record/506645engBellucci, LSilicon detector developments for CMSDetectors and Experimental TechniquesAt the end of 1999, the CMS collaboration decided for a tracking system based entirely on silicon detectors. The all silicon tracker for CMS is a major challenge in terms of performance, scale of the devices and severity of the radiation environment. To fulfill all the requirements, a large program of study and development in the field of silicon strip detectors has been carried out. The characteristics of silicon microstrip detectors were measured for different strip pitches and various strip implant and metal widths. Devices were investigated before and after irradiation. The optimization of the design parameters and choice of substrate resistivity and crystal orientation are reviewed. (8 refs).oai:cds.cern.ch:5066452001
spellingShingle Detectors and Experimental Techniques
Bellucci, L
Silicon detector developments for CMS
title Silicon detector developments for CMS
title_full Silicon detector developments for CMS
title_fullStr Silicon detector developments for CMS
title_full_unstemmed Silicon detector developments for CMS
title_short Silicon detector developments for CMS
title_sort silicon detector developments for cms
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/S0168-9002(01)00111-5
http://cds.cern.ch/record/506645
work_keys_str_mv AT belluccil silicondetectordevelopmentsforcms