Cargando…

Response of a BGO detector to photon and neutron sources: simulations and measurements

In this paper Monte Carlo simulations (FLUKA) and measurements of the response of a BGO detector are reported. %For the measurements different radioactive sources were used to irradiate the BGO crystal. For the measurements three low-energy photon emitters $\left({}^{60}\rm{Co},\right.$ ${}^{54}\rm{...

Descripción completa

Detalles Bibliográficos
Autores principales: Vincke, H H, Gschwendtner, E, Fabjan, Christian Wolfgang, Otto, T
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-9002(01)01966-0
http://cds.cern.ch/record/507785
_version_ 1780897409707016192
author Vincke, H H
Gschwendtner, E
Fabjan, Christian Wolfgang
Otto, T
author_facet Vincke, H H
Gschwendtner, E
Fabjan, Christian Wolfgang
Otto, T
author_sort Vincke, H H
collection CERN
description In this paper Monte Carlo simulations (FLUKA) and measurements of the response of a BGO detector are reported. %For the measurements different radioactive sources were used to irradiate the BGO crystal. For the measurements three low-energy photon emitters $\left({}^{60}\rm{Co},\right.$ ${}^{54}\rm{Mn},$ $\left. {}^{137}\rm{Cs}\right)$ were used to irradiate the BGO from various distances and angles. The neutron response was measured with an Am--Be neutron source. Simulations of the experimental irradiations were carried out. Our study can also be considered as a benchmark for FLUKA in terms of its reliability to predict the detector response of a BGO scintillator.
id cern-507785
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2001
record_format invenio
spelling cern-5077852019-09-30T06:29:59Zdoi:10.1016/S0168-9002(01)01966-0http://cds.cern.ch/record/507785engVincke, H HGschwendtner, EFabjan, Christian WolfgangOtto, TResponse of a BGO detector to photon and neutron sources: simulations and measurementsDetectors and Experimental TechniquesIn this paper Monte Carlo simulations (FLUKA) and measurements of the response of a BGO detector are reported. %For the measurements different radioactive sources were used to irradiate the BGO crystal. For the measurements three low-energy photon emitters $\left({}^{60}\rm{Co},\right.$ ${}^{54}\rm{Mn},$ $\left. {}^{137}\rm{Cs}\right)$ were used to irradiate the BGO from various distances and angles. The neutron response was measured with an Am--Be neutron source. Simulations of the experimental irradiations were carried out. Our study can also be considered as a benchmark for FLUKA in terms of its reliability to predict the detector response of a BGO scintillator.CERN-EP-2001-048oai:cds.cern.ch:5077852001-06-12
spellingShingle Detectors and Experimental Techniques
Vincke, H H
Gschwendtner, E
Fabjan, Christian Wolfgang
Otto, T
Response of a BGO detector to photon and neutron sources: simulations and measurements
title Response of a BGO detector to photon and neutron sources: simulations and measurements
title_full Response of a BGO detector to photon and neutron sources: simulations and measurements
title_fullStr Response of a BGO detector to photon and neutron sources: simulations and measurements
title_full_unstemmed Response of a BGO detector to photon and neutron sources: simulations and measurements
title_short Response of a BGO detector to photon and neutron sources: simulations and measurements
title_sort response of a bgo detector to photon and neutron sources: simulations and measurements
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/S0168-9002(01)01966-0
http://cds.cern.ch/record/507785
work_keys_str_mv AT vinckehh responseofabgodetectortophotonandneutronsourcessimulationsandmeasurements
AT gschwendtnere responseofabgodetectortophotonandneutronsourcessimulationsandmeasurements
AT fabjanchristianwolfgang responseofabgodetectortophotonandneutronsourcessimulationsandmeasurements
AT ottot responseofabgodetectortophotonandneutronsourcessimulationsandmeasurements