Cargando…
Response of a BGO detector to photon and neutron sources: simulations and measurements
In this paper Monte Carlo simulations (FLUKA) and measurements of the response of a BGO detector are reported. %For the measurements different radioactive sources were used to irradiate the BGO crystal. For the measurements three low-energy photon emitters $\left({}^{60}\rm{Co},\right.$ ${}^{54}\rm{...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(01)01966-0 http://cds.cern.ch/record/507785 |
_version_ | 1780897409707016192 |
---|---|
author | Vincke, H H Gschwendtner, E Fabjan, Christian Wolfgang Otto, T |
author_facet | Vincke, H H Gschwendtner, E Fabjan, Christian Wolfgang Otto, T |
author_sort | Vincke, H H |
collection | CERN |
description | In this paper Monte Carlo simulations (FLUKA) and measurements of the response of a BGO detector are reported. %For the measurements different radioactive sources were used to irradiate the BGO crystal. For the measurements three low-energy photon emitters $\left({}^{60}\rm{Co},\right.$ ${}^{54}\rm{Mn},$ $\left. {}^{137}\rm{Cs}\right)$ were used to irradiate the BGO from various distances and angles. The neutron response was measured with an Am--Be neutron source. Simulations of the experimental irradiations were carried out. Our study can also be considered as a benchmark for FLUKA in terms of its reliability to predict the detector response of a BGO scintillator. |
id | cern-507785 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2001 |
record_format | invenio |
spelling | cern-5077852019-09-30T06:29:59Zdoi:10.1016/S0168-9002(01)01966-0http://cds.cern.ch/record/507785engVincke, H HGschwendtner, EFabjan, Christian WolfgangOtto, TResponse of a BGO detector to photon and neutron sources: simulations and measurementsDetectors and Experimental TechniquesIn this paper Monte Carlo simulations (FLUKA) and measurements of the response of a BGO detector are reported. %For the measurements different radioactive sources were used to irradiate the BGO crystal. For the measurements three low-energy photon emitters $\left({}^{60}\rm{Co},\right.$ ${}^{54}\rm{Mn},$ $\left. {}^{137}\rm{Cs}\right)$ were used to irradiate the BGO from various distances and angles. The neutron response was measured with an Am--Be neutron source. Simulations of the experimental irradiations were carried out. Our study can also be considered as a benchmark for FLUKA in terms of its reliability to predict the detector response of a BGO scintillator.CERN-EP-2001-048oai:cds.cern.ch:5077852001-06-12 |
spellingShingle | Detectors and Experimental Techniques Vincke, H H Gschwendtner, E Fabjan, Christian Wolfgang Otto, T Response of a BGO detector to photon and neutron sources: simulations and measurements |
title | Response of a BGO detector to photon and neutron sources: simulations and measurements |
title_full | Response of a BGO detector to photon and neutron sources: simulations and measurements |
title_fullStr | Response of a BGO detector to photon and neutron sources: simulations and measurements |
title_full_unstemmed | Response of a BGO detector to photon and neutron sources: simulations and measurements |
title_short | Response of a BGO detector to photon and neutron sources: simulations and measurements |
title_sort | response of a bgo detector to photon and neutron sources: simulations and measurements |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(01)01966-0 http://cds.cern.ch/record/507785 |
work_keys_str_mv | AT vinckehh responseofabgodetectortophotonandneutronsourcessimulationsandmeasurements AT gschwendtnere responseofabgodetectortophotonandneutronsourcessimulationsandmeasurements AT fabjanchristianwolfgang responseofabgodetectortophotonandneutronsourcessimulationsandmeasurements AT ottot responseofabgodetectortophotonandneutronsourcessimulationsandmeasurements |