Cargando…
Performance of the CAPRICE98 balloon-borne gas-RICH detector
A RICH counter using a gas radiator of C/sub 4/F/sub 10/ and a photosensitive MWPC with pad readout has been developed, tested in particle beam at CERN and used in the CAPRICE98 balloon-borne experiment. The MWPC was operated with a TMAE and ethane mixture at atmospheric pressure and used a cathode...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(01)00202-9 http://cds.cern.ch/record/508320 |
_version_ | 1780897439061901312 |
---|---|
author | Bergström, D Boezio, M Carlson, P J Francke, T Grinstein, S Weber, N Suffert, Martin Hof, M Kremer, J Menn, W Simon, M Stephens, S A Ambriola, M Bellotti, R Cafagna, F Castellano, M G Ciacio, F Circella, M De Marzo, C Finetti, N Papini, P Piccardi, S Spillantini, P Bartalucci, S Ricci, M Bidoli, V Casolino, M De Pascale, M P Morselli, A Picozza, P Sparvoli, R Barbiellini, Guido Schiavon, R P Vacchi, A Zampa, N Mitchell, J W Ormes, J F Streitmatter, R E Bravar, U Stochaj, S J |
author_facet | Bergström, D Boezio, M Carlson, P J Francke, T Grinstein, S Weber, N Suffert, Martin Hof, M Kremer, J Menn, W Simon, M Stephens, S A Ambriola, M Bellotti, R Cafagna, F Castellano, M G Ciacio, F Circella, M De Marzo, C Finetti, N Papini, P Piccardi, S Spillantini, P Bartalucci, S Ricci, M Bidoli, V Casolino, M De Pascale, M P Morselli, A Picozza, P Sparvoli, R Barbiellini, Guido Schiavon, R P Vacchi, A Zampa, N Mitchell, J W Ormes, J F Streitmatter, R E Bravar, U Stochaj, S J |
author_sort | Bergström, D |
collection | CERN |
description | A RICH counter using a gas radiator of C/sub 4/F/sub 10/ and a photosensitive MWPC with pad readout has been developed, tested in particle beam at CERN and used in the CAPRICE98 balloon-borne experiment. The MWPC was operated with a TMAE and ethane mixture at atmospheric pressure and used a cathode pad plane to give an unambiguous image of the Cherenkov light. The induced signals in the pad plane were read our using the AMPLEX chip and CRAMS. The good efficiency of the Cherenkov light collection, the efficient detection of the weak signal from single UV photons together with a low noise level in the electronics of the RICH detector, resulted in a large number of detected photoelectrons per event. For beta approximately=1 charge one particles, an average of 12 photoelectrons per event were detected. The reconstructed Cherenkov angle of 50 mrad for a beta approximately=1 particle had a resolution of 1.2 mrad (rms). The RICH was flown with the CAPRICE98 magnetic spectrometer and was the first RICH counter ever used in a balloon-borne experiment capable of identifying charge one particles at energies above 5 GeV. The RICH provided an identification of cosmic ray antiprotons up to the highest energies ever studied (about 50 GeV of total energy). The spectrometer was flown on 28-29 May 1998 from Fort Sumner, New Mexico, USA. (21 refs). |
id | cern-508320 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2001 |
record_format | invenio |
spelling | cern-5083202019-09-30T06:29:59Zdoi:10.1016/S0168-9002(01)00202-9http://cds.cern.ch/record/508320engBergström, DBoezio, MCarlson, P JFrancke, TGrinstein, SWeber, NSuffert, MartinHof, MKremer, JMenn, WSimon, MStephens, S AAmbriola, MBellotti, RCafagna, FCastellano, M GCiacio, FCircella, MDe Marzo, CFinetti, NPapini, PPiccardi, SSpillantini, PBartalucci, SRicci, MBidoli, VCasolino, MDe Pascale, M PMorselli, APicozza, PSparvoli, RBarbiellini, GuidoSchiavon, R PVacchi, AZampa, NMitchell, J WOrmes, J FStreitmatter, R EBravar, UStochaj, S JPerformance of the CAPRICE98 balloon-borne gas-RICH detectorDetectors and Experimental TechniquesA RICH counter using a gas radiator of C/sub 4/F/sub 10/ and a photosensitive MWPC with pad readout has been developed, tested in particle beam at CERN and used in the CAPRICE98 balloon-borne experiment. The MWPC was operated with a TMAE and ethane mixture at atmospheric pressure and used a cathode pad plane to give an unambiguous image of the Cherenkov light. The induced signals in the pad plane were read our using the AMPLEX chip and CRAMS. The good efficiency of the Cherenkov light collection, the efficient detection of the weak signal from single UV photons together with a low noise level in the electronics of the RICH detector, resulted in a large number of detected photoelectrons per event. For beta approximately=1 charge one particles, an average of 12 photoelectrons per event were detected. The reconstructed Cherenkov angle of 50 mrad for a beta approximately=1 particle had a resolution of 1.2 mrad (rms). The RICH was flown with the CAPRICE98 magnetic spectrometer and was the first RICH counter ever used in a balloon-borne experiment capable of identifying charge one particles at energies above 5 GeV. The RICH provided an identification of cosmic ray antiprotons up to the highest energies ever studied (about 50 GeV of total energy). The spectrometer was flown on 28-29 May 1998 from Fort Sumner, New Mexico, USA. (21 refs).oai:cds.cern.ch:5083202001 |
spellingShingle | Detectors and Experimental Techniques Bergström, D Boezio, M Carlson, P J Francke, T Grinstein, S Weber, N Suffert, Martin Hof, M Kremer, J Menn, W Simon, M Stephens, S A Ambriola, M Bellotti, R Cafagna, F Castellano, M G Ciacio, F Circella, M De Marzo, C Finetti, N Papini, P Piccardi, S Spillantini, P Bartalucci, S Ricci, M Bidoli, V Casolino, M De Pascale, M P Morselli, A Picozza, P Sparvoli, R Barbiellini, Guido Schiavon, R P Vacchi, A Zampa, N Mitchell, J W Ormes, J F Streitmatter, R E Bravar, U Stochaj, S J Performance of the CAPRICE98 balloon-borne gas-RICH detector |
title | Performance of the CAPRICE98 balloon-borne gas-RICH detector |
title_full | Performance of the CAPRICE98 balloon-borne gas-RICH detector |
title_fullStr | Performance of the CAPRICE98 balloon-borne gas-RICH detector |
title_full_unstemmed | Performance of the CAPRICE98 balloon-borne gas-RICH detector |
title_short | Performance of the CAPRICE98 balloon-borne gas-RICH detector |
title_sort | performance of the caprice98 balloon-borne gas-rich detector |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(01)00202-9 http://cds.cern.ch/record/508320 |
work_keys_str_mv | AT bergstromd performanceofthecaprice98balloonbornegasrichdetector AT boeziom performanceofthecaprice98balloonbornegasrichdetector AT carlsonpj performanceofthecaprice98balloonbornegasrichdetector AT francket performanceofthecaprice98balloonbornegasrichdetector AT grinsteins performanceofthecaprice98balloonbornegasrichdetector AT webern performanceofthecaprice98balloonbornegasrichdetector AT suffertmartin performanceofthecaprice98balloonbornegasrichdetector AT hofm performanceofthecaprice98balloonbornegasrichdetector AT kremerj performanceofthecaprice98balloonbornegasrichdetector AT mennw performanceofthecaprice98balloonbornegasrichdetector AT simonm performanceofthecaprice98balloonbornegasrichdetector AT stephenssa performanceofthecaprice98balloonbornegasrichdetector AT ambriolam performanceofthecaprice98balloonbornegasrichdetector AT bellottir performanceofthecaprice98balloonbornegasrichdetector AT cafagnaf performanceofthecaprice98balloonbornegasrichdetector AT castellanomg performanceofthecaprice98balloonbornegasrichdetector AT ciaciof performanceofthecaprice98balloonbornegasrichdetector AT circellam performanceofthecaprice98balloonbornegasrichdetector AT demarzoc performanceofthecaprice98balloonbornegasrichdetector AT finettin performanceofthecaprice98balloonbornegasrichdetector AT papinip performanceofthecaprice98balloonbornegasrichdetector AT piccardis performanceofthecaprice98balloonbornegasrichdetector AT spillantinip performanceofthecaprice98balloonbornegasrichdetector AT bartaluccis performanceofthecaprice98balloonbornegasrichdetector AT riccim performanceofthecaprice98balloonbornegasrichdetector AT bidoliv performanceofthecaprice98balloonbornegasrichdetector AT casolinom performanceofthecaprice98balloonbornegasrichdetector AT depascalemp performanceofthecaprice98balloonbornegasrichdetector AT morsellia performanceofthecaprice98balloonbornegasrichdetector AT picozzap performanceofthecaprice98balloonbornegasrichdetector AT sparvolir performanceofthecaprice98balloonbornegasrichdetector AT barbielliniguido performanceofthecaprice98balloonbornegasrichdetector AT schiavonrp performanceofthecaprice98balloonbornegasrichdetector AT vacchia performanceofthecaprice98balloonbornegasrichdetector AT zampan performanceofthecaprice98balloonbornegasrichdetector AT mitchelljw performanceofthecaprice98balloonbornegasrichdetector AT ormesjf performanceofthecaprice98balloonbornegasrichdetector AT streitmatterre performanceofthecaprice98balloonbornegasrichdetector AT bravaru performanceofthecaprice98balloonbornegasrichdetector AT stochajsj performanceofthecaprice98balloonbornegasrichdetector |