Cargando…

Accuracy of the LEP Spectrometer Beam Orbit Monitors

At the LEP e+/e- collider, a spectrometer is used to determine the beam energy with a target accuracy of 10-4. The spectrometer measures the lattice dipole bending angle of the beam using six beam position monitors (BPMs). The required calibration error imposes a BPM accuracy of a 10-6 m correspondi...

Descripción completa

Detalles Bibliográficos
Autores principales: Barbero, E, Dehning, Bernd, Prochnow, J, Bergoz, J, Unser, K, Matheson, J, Torrence, E
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:http://cds.cern.ch/record/509286
_version_ 1780897465299369984
author Barbero, E
Dehning, Bernd
Prochnow, J
Bergoz, J
Unser, K
Matheson, J
Torrence, E
author_facet Barbero, E
Dehning, Bernd
Prochnow, J
Bergoz, J
Unser, K
Matheson, J
Torrence, E
author_sort Barbero, E
collection CERN
description At the LEP e+/e- collider, a spectrometer is used to determine the beam energy with a target accuracy of 10-4. The spectrometer measures the lattice dipole bending angle of the beam using six beam position monitors (BPMs). The required calibration error imposes a BPM accuracy of a 10-6 m corresponding to a relative electrical signal variation of 2. 10-5. The operating parameters have been compared with beam simulator results and non-linearBPM response simulations. The relative beam current variations between 0.02 and 0.03 and position changes of 0.1 mm during the fills of last year lead to uncertainties in the orbit measurements of well below 10-6 m. For accuracy tests absolute beam currents were varied by a factor of three. The environment magnetical field is introduced to correct orbit readings. The BPM linearity and calibration was checked using moveable supports and wire position sensors. The BPM triplet quantity is used to determine the orbit position monitors accuracy. The BPM triplet changed during the fills between 1 and 2 10-6 m RMS, which indicates a single BPM orbit determination accuracy between 1 and 1.5 10-6 m.
id cern-509286
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2001
record_format invenio
spelling cern-5092862023-05-05T13:08:03Zhttp://cds.cern.ch/record/509286engBarbero, EDehning, BerndProchnow, JBergoz, JUnser, KMatheson, JTorrence, EAccuracy of the LEP Spectrometer Beam Orbit MonitorsAccelerators and Storage RingsAt the LEP e+/e- collider, a spectrometer is used to determine the beam energy with a target accuracy of 10-4. The spectrometer measures the lattice dipole bending angle of the beam using six beam position monitors (BPMs). The required calibration error imposes a BPM accuracy of a 10-6 m corresponding to a relative electrical signal variation of 2. 10-5. The operating parameters have been compared with beam simulator results and non-linearBPM response simulations. The relative beam current variations between 0.02 and 0.03 and position changes of 0.1 mm during the fills of last year lead to uncertainties in the orbit measurements of well below 10-6 m. For accuracy tests absolute beam currents were varied by a factor of three. The environment magnetical field is introduced to correct orbit readings. The BPM linearity and calibration was checked using moveable supports and wire position sensors. The BPM triplet quantity is used to determine the orbit position monitors accuracy. The BPM triplet changed during the fills between 1 and 2 10-6 m RMS, which indicates a single BPM orbit determination accuracy between 1 and 1.5 10-6 m.CERN-SL-2001-022-BIoai:cds.cern.ch:5092862001-05-01
spellingShingle Accelerators and Storage Rings
Barbero, E
Dehning, Bernd
Prochnow, J
Bergoz, J
Unser, K
Matheson, J
Torrence, E
Accuracy of the LEP Spectrometer Beam Orbit Monitors
title Accuracy of the LEP Spectrometer Beam Orbit Monitors
title_full Accuracy of the LEP Spectrometer Beam Orbit Monitors
title_fullStr Accuracy of the LEP Spectrometer Beam Orbit Monitors
title_full_unstemmed Accuracy of the LEP Spectrometer Beam Orbit Monitors
title_short Accuracy of the LEP Spectrometer Beam Orbit Monitors
title_sort accuracy of the lep spectrometer beam orbit monitors
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/509286
work_keys_str_mv AT barberoe accuracyofthelepspectrometerbeamorbitmonitors
AT dehningbernd accuracyofthelepspectrometerbeamorbitmonitors
AT prochnowj accuracyofthelepspectrometerbeamorbitmonitors
AT bergozj accuracyofthelepspectrometerbeamorbitmonitors
AT unserk accuracyofthelepspectrometerbeamorbitmonitors
AT mathesonj accuracyofthelepspectrometerbeamorbitmonitors
AT torrencee accuracyofthelepspectrometerbeamorbitmonitors