Beam Measurement Systems for the CERN Antiproton Decelerator (AD)
The new, low-energy antiproton physics facility at CERN has been successfully commissioned and has been delivering decelerated antiprotons at 100 MeV/c since July 2000. The AD consists of one ring where the 3.5 GeV/c antiprotons produced from a production target are injected, rf manipulated, stochas...
Autores principales: | , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/510663 |
_version_ | 1780897497430884352 |
---|---|
author | Angoletta, Maria Elena Chohan, V Ludwig, M Marqversen, O Odier, P Pedersen, F Raich, U Søby, L Tranquille, G Spickermann, T |
author_facet | Angoletta, Maria Elena Chohan, V Ludwig, M Marqversen, O Odier, P Pedersen, F Raich, U Søby, L Tranquille, G Spickermann, T |
author_sort | Angoletta, Maria Elena |
collection | CERN |
description | The new, low-energy antiproton physics facility at CERN has been successfully commissioned and has been delivering decelerated antiprotons at 100 MeV/c since July 2000. The AD consists of one ring where the 3.5 GeV/c antiprotons produced from a production target are injected, rf manipulated, stochastically cooled, decelerated (with further stages involving additional stochastic and electron cooling and rf manipulation) and extracted at 100 MeV/c. While proton test beams of sufficient intensity could be used for certain procedures in AD commissioning, this was not possible for setting-up and routine operation. Hence, special diagnostics systems had to be developed to obtain the beam and accelerator characteristics using the weak antiproton beams of a few 10E7 particles at all momenta from 3.5 GeV/c down to 100 MeV/c. These include systems for position measurement, intensity, beam size measurements using transverse aperture limiters and scintillators and Schottky-based tools. This paper gives an overall view of these systems and their usage. |
id | cern-510663 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2001 |
record_format | invenio |
spelling | cern-5106632021-11-11T09:54:04Zhttp://cds.cern.ch/record/510663engAngoletta, Maria ElenaChohan, VLudwig, MMarqversen, OOdier, PPedersen, FRaich, USøby, LTranquille, GSpickermann, TBeam Measurement Systems for the CERN Antiproton Decelerator (AD)Accelerators and Storage RingsThe new, low-energy antiproton physics facility at CERN has been successfully commissioned and has been delivering decelerated antiprotons at 100 MeV/c since July 2000. The AD consists of one ring where the 3.5 GeV/c antiprotons produced from a production target are injected, rf manipulated, stochastically cooled, decelerated (with further stages involving additional stochastic and electron cooling and rf manipulation) and extracted at 100 MeV/c. While proton test beams of sufficient intensity could be used for certain procedures in AD commissioning, this was not possible for setting-up and routine operation. Hence, special diagnostics systems had to be developed to obtain the beam and accelerator characteristics using the weak antiproton beams of a few 10E7 particles at all momenta from 3.5 GeV/c down to 100 MeV/c. These include systems for position measurement, intensity, beam size measurements using transverse aperture limiters and scintillators and Schottky-based tools. This paper gives an overall view of these systems and their usage.CERN-PS-2001-053-BDoai:cds.cern.ch:5106632001-07-24 |
spellingShingle | Accelerators and Storage Rings Angoletta, Maria Elena Chohan, V Ludwig, M Marqversen, O Odier, P Pedersen, F Raich, U Søby, L Tranquille, G Spickermann, T Beam Measurement Systems for the CERN Antiproton Decelerator (AD) |
title | Beam Measurement Systems for the CERN Antiproton Decelerator (AD) |
title_full | Beam Measurement Systems for the CERN Antiproton Decelerator (AD) |
title_fullStr | Beam Measurement Systems for the CERN Antiproton Decelerator (AD) |
title_full_unstemmed | Beam Measurement Systems for the CERN Antiproton Decelerator (AD) |
title_short | Beam Measurement Systems for the CERN Antiproton Decelerator (AD) |
title_sort | beam measurement systems for the cern antiproton decelerator (ad) |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/510663 |
work_keys_str_mv | AT angolettamariaelena beammeasurementsystemsforthecernantiprotondeceleratorad AT chohanv beammeasurementsystemsforthecernantiprotondeceleratorad AT ludwigm beammeasurementsystemsforthecernantiprotondeceleratorad AT marqverseno beammeasurementsystemsforthecernantiprotondeceleratorad AT odierp beammeasurementsystemsforthecernantiprotondeceleratorad AT pedersenf beammeasurementsystemsforthecernantiprotondeceleratorad AT raichu beammeasurementsystemsforthecernantiprotondeceleratorad AT søbyl beammeasurementsystemsforthecernantiprotondeceleratorad AT tranquilleg beammeasurementsystemsforthecernantiprotondeceleratorad AT spickermannt beammeasurementsystemsforthecernantiprotondeceleratorad |