The CLIC Study of Magnet Stability and Time-dependent Luminosity Performance

The present parameters of the CLIC study require the collision of small emittance beams with a vertical spot size of 1 nm. The tolerances on vertical quadrupole vi-bration (above a few Hz) are as small as a few nm in the linac and most of the Final Focus. The final focusing quadrupole has a stabilit...

Descripción completa

Detalles Bibliográficos
Autores principales: Aleksa, Martin, Assmann, R W, Coosemans, Williame, Guignard, Gilbert, Leros, Nicolas, Mayoud, Michel, Redaelli, S, Ruggiero, F, Russenschuck, Stephan, Schulte, Daniel, Wilson, Ian H, Zimmermann, Frank
Lenguaje:eng
Publicado: 2001
Materias:
Acceso en línea:http://cds.cern.ch/record/512353
Descripción
Sumario:The present parameters of the CLIC study require the collision of small emittance beams with a vertical spot size of 1 nm. The tolerances on vertical quadrupole vi-bration (above a few Hz) are as small as a few nm in the linac and most of the Final Focus. The final focusing quadrupole has a stability requirement of 4 nm in the horizontal and 0.2 nm in the vertical direction. Those tol-erances can only be achieved with the use of damped support structures for CLIC. A study has been set-up at CERN to explore the application of stabilization devices from specialized industry and to predict the time-dependent luminosity performance for CLIC. The results will guide the specification of required technological im-provements and will help to verify the feasibility of the present CLIC parameters.